scholarly journals Investigation of the range of motion of the shoulder joint in subjects with rotator cuff arthropathy while performing daily activities

Author(s):  
Mohammad Taghi Karimi ◽  
Sahar Khademi

Background: Patients who have rotator cuff arthropathy experience a limited range of motion (ROM) of the shoulder joint and experience problems in performing their daily activities; however, no evidence is available to suggest the exact ROM of the shoulder joint in this population. Therefore, this study sought to determine the degree of motion of the shoulder joint in three planes during different activities.Methods: Five subjects with rotator cuff injuries participated in this study. The motion of the shoulder joints on both the involved and normal sides was assessed by a motion analysis system while performing forward abduction (task 1), flexion (task 2), and forward flexion (task 3). The OpenSIM software program was used to determine the ROM of the shoulder joints on both sides. The difference between the ranges of motion was determined using a two-sample t-test. Results: The ROMs of the shoulder joint in task 1 were 35°±16.5°, 72.1°±2.6°, and 103.9°±28.7° degrees for flexion, abduction, and rotation, respectively, on the normal side and 28°±19.8°, 31°±31.56°, and 48°±33.5° on the involved side (p<0.05). There was no significant difference between the flexion/extension and rotation movements of the shoulder joint when performing task 1. However, the difference between flexion and rotation movements of the shoulder joints for the second task was significant (p˃0.05).Conclusions: Those with rotator cuff arthropathy have functional limitations due to muscle weakness and paralysis, especially during the vertical reaching task. However, although these individuals have decreased ROM for transverse reaching tasks, the reduction was not significant.

2021 ◽  
Vol 71 (3) ◽  
pp. 819-22
Author(s):  
Sumeera Matee ◽  
Wasif Anwar ◽  
Sami Wahid ◽  
Saeed Bin Ayaz ◽  
Rana Shahid ◽  
...  

Objective: To compare the efficacy of intra-articular injection of methyl prednisolone with ketorolac for improvement in range of motion in various shoulder joint disorders. Study Design: Quasi-experimental study. Place and Duration of Study: Departments of Internal and Rehabilitation Medicine, Combined Military Hospital Mangla, from Nov 2018 to May 2019. Methodology: Through non-probability consecutive sampling, patients with shoulder disorders were enrolled in the study and divided into two groups. Group A received intra articular corticosteroid injection and group B received intra-articular Ketorolac injection. Outcome was measured in terms of improvement in shoulder range of motion. Results: A total of 60 patients were selected, 40 (66.7%) male and 20 (33.3%) female. 30 (50%) patients had adhesive capsulitis, 24 (40%) had rotator cuff syndrome and 6 (10%) had impingement syndrome. 24 patients received methyl prednisolone acetate injection while 36 received ketorolac injection. There was no significant difference in the mean gain in flexion, extension, abduction, internal or external rotation between both groups (p=0.224, p=0.261, p=0.884, p=0.238, and p=0.584 respectively). Conclusion: There was no significant difference in efficacy of corticosteroid and ketorolac when injected intra-articularly in shoulder joint disorders.


2020 ◽  
Vol 3 (3) ◽  
pp. 88-96
Author(s):  
Ine Sintia ◽  
Nyimas Fatimah

Background: Frozen shoulder is a condition of the shoulder joint that experiences inflammation, pain, adhesions, atrophyand shortening of the joint capsule resulting in limited motion. In frozen shoulder patients, the limited range of motion ofthe shoulder joint can affect and reduce functional ability. This study aims to analyze the correlation between the limitedarea of motion of the shoulder joint with the functional ability of frozen shoulder patients at the Medical RehabilitationInstallation Dr. Mohammad Hoesin Palembang. Methods: This study was an observational analytic study, correlationtest, with a cross sectional design. There were 29 frozen shoulder patients who met the inclusion criteria in the MedicalRehabilitation Installation Dr. Mohammad Hoesin Palembang in November 2018 was taken as a sample using consecutivesampling techniques. Functional ability was assessed using the quickDASH questionnaire and the area of motion wasmeasured using a goniometer, then analyzed. Results: The results of the correlation test showed significant resultsbetween functional abilities and the area of motion of the shoulder joints. Active flexion (p = 0.000; r = -0.669), activeextension (p = 0.004; r = -0.520), active abduction (p = 0.000; r = -0.663), active adduction (p = 0.022; r = -0.423 ), passiveflexion (p = 0.001; r = -0.589), passive extension (p = 0.002; r = -0.543), passive abduction (p = 0.000; r = -0.676), passiveadduction (p = 0.038; r = -0.388). Conclusion: There is a significant correlation between limited joint motion andfunctional ability in frozen shoulder patients at the Medical Rehabilitation Installation of Dr. Mohammad HoesinPalembang


Author(s):  
Derek Lura ◽  
Rajiv Dubey ◽  
Stephanie L. Carey ◽  
M. Jason Highsmith

The prostheses used by the majority of persons with hand/arm amputations today have a very limited range of motion. Transradial (below the elbow) amputees lose the three degrees of freedom provided by the wrist and forearm. Some myoeletric prostheses currently allow for forearm pronation and supination (rotation about an axis parallel to the forearm) and the operation of a powered prosthetic hand. Older body-powered prostheses, incorporating hooks and other cable driven terminal devices, have even fewer degrees of freedom. In order to perform activities of daily living (ADL), a person with amputation(s) must use a greater than normal range of movement from other body joints to compensate for the loss of movement caused by the amputation. By studying the compensatory motion of prosthetic users we can understand the mechanics of how they adapt to the loss of range of motion in a given limb for select tasks. The purpose of this study is to create a biomechanical model that can predict the compensatory motion using given subject data. The simulation can then be used to select the best prosthesis for a given user, or to design prostheses that are more effective at selected tasks, once enough data has been analyzed. Joint locations necessary to accomplish the task with a given configuration are calculated by the simulation for a set of prostheses and tasks. The simulation contains a set of prosthetic configurations that are represented by parameters that consist of the degrees of freedom provided by the selected prosthesis. The simulation also contains a set of task information that includes joint constraints, and trajectories which the hand or prosthesis follows to perform the task. The simulation allows for movement in the wrist and forearm, which is dependent on the prosthetic configuration, elbow flexion, three degrees of rotation at the shoulder joint, movement of the shoulder joint about the sternoclavicular joint, and translation and rotation of the torso. All joints have definable restrictions determined by the prosthesis, and task.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Binghao Zhao ◽  
Qingsong Zhang ◽  
Bo Liu

Abstract Background The study aimed to explore the additional value of repair of Lafosse I subscapularis injury compared with debridement in anterosuperior rotator cuff injury. Methods The prospective study was conducted on a total of 41 patients with supraspinatus tendon tear combined with Lafosse I subscapularis injury. Eighteen patients were divided into the repair group and 23 patients were divided into the non-repair group. The two groups were compared for intraoperative parameters, pain score, range of motion of the shoulder joint, shoulder joint function and quality of life (QoL) at pre-operation, 3 and 6 months postoperatively and the final follow-up visit. Results The width of supraspinatus tendon tear did not exceed 3 cm and did not retract beyond the glenoid in among patients. There was no statistical difference of preoperative data between two groups, including age, course of disease, positive Jobe test, positive Bear-hug test, positive Lift-off test, Patte stage, longitudinal tear and pain severity (P > 0.05). Compared to preoperative levels, the severity of pain, ASES scores and EQ-5D-3L scores were significantly lower at 3 and 6 months postoperatively and the final position (P < 0.05). However, there was no statistical difference in pain severity, ASES scores and EQ-5D-3L scores between repair group and non-repair group (P > 0.05). Similarly, compared to preoperative levels, the range of motion of shoulder joint was significantly improved after operation, including internal rotation, external rotation, forward flexion and elevation (P < 0.05). However, there was no statistical difference in range of motion of shoulder joint between repair group and non-repair group (P > 0.05). Conclusion Operative treatment can effectively lessen severity of pain in the patients, improve shoulder joint function, increase the range of motion of the shoulder joint and enhance the QoL in treating anterosuperior rotator cuff injury. However, repair of subscapularis brings no benefit compared to debridement in treating supraspinatus tendon tear combined with Lafosse I subscapularis injury.


2019 ◽  
Vol 2 (2) ◽  
pp. 189-200
Author(s):  
Yestiani Norita Joni ◽  
Busjra M Nur ◽  
Fitrian Rayasari

The purpose of this study is to know the effectiveness of intradialysis exercise using barbells and Range of Motion (ROM) on the adequacy of hemodialysis in patients with chronic kidney disease in the hemodialysis room of RSIJ Sukapura in 2018. The design of this study uses a design with non-probability pre and post test two groups without control design . The result of the difference in the effectiveness of the adequacy values between the two intervention groups after the intervention was given was the barbell intervention obtained 1,33 with a standard deviation of 0.485, an error standard of 0.114. Whereas in the ROM intervention group 1.67 the standard deviation was 0.485, the standard error was 0.114 and the p-value was 0.047 (> 0.05). Conclusion, there was no significant difference in the value of hemodialysis adequacy between the barbellROM intervention groups after the intervention.   Keywords: Hemodialysis Adequacy, Barbell, Exercise Effectiveness, Intradialysis, Range Of Motion (ROM)


2021 ◽  
Author(s):  
Sergi Gil-Gonzalez ◽  
Ricardo Andrés Barja Rodriguez ◽  
Antoni Lopez Pujol ◽  
Hussein Berjaoui ◽  
Jose Enrique Fernandez Bengoa ◽  
...  

Abstract Background. This study aimed to assess whether use of continuous passive motion (CPM) can improve range of motion in patients after total knee arthroplasty (TKA). Moreover, the relationship between the use of CPM with the surgical wound aspect (SWA) and pain management after TKA was analysed.Methods. We randomized 210 patients, 102 patients in the CPM group, who received a standard rehabilitation protocol together with CPM application; and 108 patients in the no-CPM group, without CPM. Variables as knee motion (flexion, extension, range of motion) and pain was measured before surgery, on the 1s, 2nd and 3rd postoperative day, and in the 2nd, 6th, 12th and 24th postoperative weeks following TKA. The SWA was determined by the “surgical wound aspect score” (SWAS) in the next 48 hours after surgery. This scale analyses swelling, erythema, haematoma, blood drainage and blisters. Results. There was an improvement in the knee motion over the course of follow-up in both groups, without significant difference in flexion parameter. We found no significant differences in the total score of SWA, except for haematoma, with less severity in the CPM group. Furthermore, we found no differences in the others SWAS parameters and pain. Conclusions. The application of CPM does not provide benefit to our patients undergoing TKA in terms of either improved flexion mobility or decreased pain. No relationship was found between the use of CPM and the global score of SWA following a TKA, except for a decrease in haematoma appearance.


2014 ◽  
Vol 2 (11_suppl3) ◽  
pp. 2325967114S0026
Author(s):  
Melih Malkoç ◽  
Ozgur Korkmaz ◽  
Ali Seker ◽  
Mehmet Isyar ◽  
Ismail Oltulu ◽  
...  

Objectives: The goals of this retrospective study are to emphasize that the patients who have non surgical treatments for several times due to the massive swelling in their knees should be considered the SL and this pathology is treatable by arthroscopic synovectomy Methods: Seventeen patients (four female and thirteen male), were evaluated retrospectively from May 2009 and April 2013. Mean age for female group was 34,75 (range between 32 to 41) and for male group was 34,23 (range between 26 to 46). Mean follow-up period was 14,76 months (range between 6 months and 38 months). Mean duration of compliance was 26,23 months (range between 9 to 96) months. All patients rated by Knee Society Score preoperatively and postoperatively arthroscopic synovectomy, performed by using radiofrequency ablation and arthroscopic shaver for treatment procedure. Patients were discharged at the end of the one day hospitalization. Postoperatively all patients were allowed to full range of motion and full weight-bearing within one day after surgery. Results: Patients were evaluated preoperatively and postoperatively using the Knee Society Score. The mean Knee Society Score was 67,82 preoperatively and 88,23 was postoperatively. There is significant difference between preoperative and postoperative Knee Society scores.(p <0.05) At the end of the three months, MRI studied and there was no clue of recurrence except two patients. All patients returned to their daily activities with full of range of motion and without swelling of the affected knee joints. At the microscopic histological studies were reported as synovial lipomatosis for all patients Conclusion: Arthroscopic synovectomy is the safe and dramatically effective method of treatment in synovial lipomatosis with less complication, curability and retrieving patients full range of motion with no limitation in their daily activities


2018 ◽  
Vol 27 (1) ◽  
pp. 24-29 ◽  
Author(s):  
Jae Guk Kim ◽  
Sung Hwan Bang ◽  
Gu Hyun Kang ◽  
Yong Soo Jang ◽  
Wonhee Kim ◽  
...  

Background: The cervical collar has been used as a common device for the initial stabilization of the cervical spine. Although many cervical collars are commercially available, there is no consensus on which offers the greatest protection, with studies showing considerable variations in their ability to restrict cervical range of motion. The use of the XCollar (Emegear, Carpinteria, CA) has been known to decrease the risk of spinal cord injury by minimizing potential cervical spinal distraction. We compared XCollar with two other cervical collars commonly used for adult patients with cervical spine injury to evaluate the difference in effectiveness between the three cervical collars to restrict cervical range of motion. Objectives: This study aimed to evaluate the difference between the three cervical collars in their ability to restrict cervical range of motion. Method: A total of 30 healthy university students aged 21–25 years participated in this study. Participants with any cervical disease and symptoms were excluded. Three cervical collars were tested: Philadelphia® Collar, Stifneck® Select™ Collar, and XCollar. A digital camera and an image-analysis technique were used to evaluate cervical range of motion during flexion, extension, bilateral bending and bilateral axial rotation. Cervical range of motion was evaluated in both the unbraced and braced condition. Results: XCollar permitted less than a mean of 10° of movement during flexion, extension, bilateral bending and bilateral axial rotation. This was less than the movement permitted by the other two cervical collars. Conclusion: XCollar presented superior cervical immobilization compared to the other two commonly used cervical collars in this study. Thus, when cervical collar is considered for an adult patient with cervical spine injury, XCollar might be one of the considerate options as a cervical immobilization device.


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Markus A. Wimmer ◽  
William Nechtow ◽  
Thorsten Schwenke ◽  
Kirsten C. Moisio

Walking is only one of many daily activities performed by patients following total knee replacement (TKR). The purpose of this study was to examine the hypotheses (a) that subject activity characteristics are correlated with knee flexion range of motion (ROM) and (b) that there is a significant difference between the subject’s flexion/extension excursion throughout the day and the ISO specified input for knee wear testing. In order to characterize activity, the number of walking and stair stepping cycles, the time spent with dynamic and stationary activities, the number of activity sequences, and the knee flexion/extension excursion of 32 TKR subjects were collected during daily activity. Flexion/extension profiles were compared with the ISO 14243 simulator input profile using a level crossing classification algorithm. Subjects took an average of 3102 (range: 343–5857) walking cycles including 65 (range: 0–319) stair stepping cycles. Active and passive ROMs were positively correlated with stair walking time, stair step counts, and stair walking sequences. Simulated knee motion according to ISO showed significantly fewer level crossings at the flexion angles 20–40° and beyond 50° than those measured with the monitor. This suggests that implant wear testing protocols should contain more cycles and a variety of activities requiring higher knee flexion angles with incorporated resting/transition periods to account for the many activity sequences.


2019 ◽  
Vol 21 (6) ◽  
pp. 417-426
Author(s):  
Kamil Yamak ◽  
Hüseyin Gökhan Karahan ◽  
Taşkın Altay ◽  
Cemil Kayalı ◽  
Fırat Ozan

Background. The aim of this study was to evaluate the clinical and radiographic results of surgical treatment of irreparable rotator cuff tears by subacromial balloon spacer insertion in patients over 65 years old. Material and methods. Results of patients with failed conservative treatment for irreparable rotator cuff tears and who underwent subacromial balloon spacer insertion were evaluated retrospectively. The VAS and Quick-DASH scores were used for clinical and functional assessment. Results. Eleven patients were included. Mean age of patients was 69.1 (range: 65-77) years old. Evaluation of anteroposterior shoulder x-rays revealed Hamada grade 2 and grade 1 arthropathy in 10 patients (91%) and 1 patient (9%),respectively. Mean duration of follow-up was 45.09 (±5.43,37-52) months. The difference in the subacromial space measured from standard AP shoulder x-rays in the preoperative period, in the 6th postoperative month, and at the end of follow-up was 5.44 mm (2.29), 6.51 mm (±2.23), and 5.08 mm (±2.13), respectively. Mean Quick-DASH score was 74.49(±14.36) in the preoperative period, compared to 72.19 (±14.38) at the end of follow-up. There was no statistically significant difference between preoperative period and end of follow-up scores in terms of mean Quick-DASH scores (p= 0.232). Mean VAS score was 7.09 (±0.831) in the preoperative period and 6.64 (±0.809) at the end of follow-up. No statistically significant difference was revealed in terms of mean VAS scores when preoperative and end of follow-up scores were compared (p=0.333). Conclusion. Clinical and radiographic results of subacromial balloon spacer insertion in the treatment of irreparable rotator cuff tears could not be evaluated as satisfactory.


Sign in / Sign up

Export Citation Format

Share Document