scholarly journals Surgical Treatment of the Fracture of the Scapular Body

2008 ◽  
Vol 11 (2) ◽  
pp. 150-157 ◽  
Author(s):  
In-Hyeok Rhyou ◽  
Bo-Gun Suh ◽  
Chae-Ik Chung ◽  
Kyung-Chul Kim
2012 ◽  
Vol 2012 ◽  
pp. 1-7 ◽  
Author(s):  
Pramod B. Voleti ◽  
Surena Namdari ◽  
Samir Mehta

The scapula plays a critical role in the association between the upper extremity and the axial skeleton. Fractures of the scapula account for 0.4% to 1% of all fractures and have an annual incidence of approximately 10 per 100,000 inhabitants. Scapular fractures typically result from a high-energy blunt-force mechanism and are often associated with other traumatic injuries. The present review focuses on the presentation, diagnosis, and treatment of fractures of the scapula. Indications for surgical treatment of glenoid fossa, scapular neck, and scapular body fractures are presented in detail. Finally, the authors’ preferred surgical technique, including positioning, approach, reduction, fixation, and post-operative management, is described.


Author(s):  
M.D. Graham

The recent development of the scanning electron microscope has added great impetus to the study of ultrastructural details of normal human ossicles. A thorough description of the ultrastructure of the human ossicles is required in order to determine changes associated with disease processes following medical or surgical treatment.Human stapes crura were obtained at the time of surgery for clinical otosclerosis and from human cadaver material. The specimens to be examined by the scanning electron microscope were fixed immediately in the operating room in a cold phosphate buffered 2% gluteraldehyde solution, washed with Ringers, post fixed in cold 1% osmic acid and dehydrated in graded alcohol. Specimens were transferred from alcohol to a series of increasing concentrations of ethyl alcohol and amyl acetate. The tissue was then critical point dried, secured to aluminum stubs and coated with gold, approximately 150A thick on a rotating stage in a vacuum evaporator. The specimens were then studied with the Kent-Cambridge S4-10 Scanning Electron Microscope at an accelerating voltage of 20KV.


2001 ◽  
Vol 120 (5) ◽  
pp. A401-A401
Author(s):  
M BOERMEESTER ◽  
E BELT ◽  
B LAMME ◽  
M LUBBERS ◽  
J KESECIOGLU ◽  
...  

1958 ◽  
Vol 34 (2) ◽  
pp. 269-277 ◽  
Author(s):  
Harold Lincoln Thompson

2007 ◽  
Vol 177 (4S) ◽  
pp. 411-412
Author(s):  
Javier Miller ◽  
Angela Smith ◽  
Kris Gunn ◽  
Erik Kouba ◽  
Eric M. Wallen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document