scholarly journals AVALIAÇÃO DA QUALIDADE MICROBIOLÓGICA DO GENGIBRE IN NATURA COMERCIALIZADO NA REGIÃO METROPOLITANA DE CURITIBA, PR

2004 ◽  
Vol 5 (2) ◽  
Author(s):  
Eliane Rose Serpe ELPO ◽  
Raquel Rejane Bonato NEGRELLE ◽  
Eliane Carneiro GOMES

Analisou-se 10 amostras de gengibre “in natura” com objetivo de caracterizar o perfil microbiológico deste produto comercializado na região metropolitana de Curitiba, PR (Brasil). Para tanto, foram realizadas a determinação do número mais provável (NMP) de coliformes totais, coliformes a 45º C/g e Escherichia coli, e a presença de Salmonella sp em 25 gramas. Os resultados indicaram que 100% das amostras atenderam ao padrão da legislação vigente para Salmonella sp, enquanto que 30% das amostras de gengibre enquadradas como raízes, tubérculos e similares, e cerca de 50% das amostras como especiarias, temperos, condimentos e similares apresentaram coliformes a 45º C/g. Destas amostras analisadas, 20% confirmaram a presença de Escherichia coli. Observou-se que todas as amostras mostraram elevados índices de coliformes totais, apesar de não haver limite máximo estabelecido pela legislação vigente. Os resultados obtidos podem ser indicativos de inadequações nos procedimentos de beneficiamento pós-colheita e de comercialização. Abstract Ten samples of natural ginger, commercialized in Curitiba, Paraná (Brazil), were analyzed for microbiological quality. The microbiological analysis measured the total coliforms, 45° C/g coliforms, the most probable number (MPN) of Escherichia coli and the presence of Salmonella sp. The results revealed that 100% of the samples complied with the required standard for the absence of Salmonella sp. On the other hand, 30% - 50% had 45º C/g coliforms and 20% of them contained Escherichia coli. It was observed that all the samples had a high value for the total coliforms. This is important since the current legislation does not establish any limits. The results obtained may indicate inadequate procedures for post-harvesting and commercial handling.

2016 ◽  
Vol 2016 ◽  
pp. 1-6 ◽  
Author(s):  
Sohana Al Sanjee ◽  
Md. Ekramul Karim

The present study aims at the microbiological analysis of export oriented frozen fishes, namely, Jew fish, Tongue Sole fish, Cuttle fish, Ribbon fish, Queen fish, and fish processing water and ice from a view of public health safety and international trade. Microbiological analysis includes the determination of total viable aerobic count by standard plate count method and enumeration of total coliforms and fecal coliforms by most probable number method. The presence of specific fish pathogens such asSalmonellaspp. andVibrio choleraewere also investigated. The TVAC of all the samples was estimated below5×105 cfu/g whereas the total coliforms and fecal coliforms count were found below 100 MPN/g and 10 MPN/g, respectively, which meet the acceptable limit specified by International Commission of Microbiological Specification for Food. The microbiological analysis of water and ice also complies with the specifications havingTVAC<20 cfu/mL, and total coliforms and fecal coliforms count were below the limit detection of the MPN method. Specific fish pathogens such asSalmonellasp. andV. choleraewere found absent in all the samples under the investigation. From this study, it can be concluded that the investigated frozen fishes were eligible for export purpose and also safe for human consumption.


2009 ◽  
Vol 39 (6) ◽  
pp. 1836-1841 ◽  
Author(s):  
Thaís Mioto Martineli ◽  
Oswaldo Durival Rossi Junior ◽  
Natacha Deboni Cereser ◽  
Marita Vedovelli Cardozo ◽  
Cristianne Lino Fontoura ◽  
...  

The consumption of lamb meat in Brazil has increased in the last years but little information about the microbiological quality of this product is available. To evaluate the hygienic-sanitary conditions of lamb carcasses, the quantification of microorganism populations indicators (mesophiles and psychrotrophs; total and thermotolerant coliforms; Escherichia coli; moulds and yeasts) and the pathogenic microorganisms indentification (Salmonella sp. and Listeria spp.) were performed. A total of 60 lamb carcasses were sampled from one abattoir in São Paulo. Swab samples were collected from three points (forequarter, back and hindquarter) on the muscle surface after carcasses final washing. Statistical analysis consisted of descriptive evaluation of the results whose counts were grouped by intervals of microorganism populations. Counts ranged from 1.0 x 10¹ to 8.0 x 10(4) colony-forming unit cm-2 (CFU cm-2) for mesophiles; 1.0 x 10(0) to 4.4 x 10(4)CFU cm-2 for psychrotrophs; < 1.0 x 10(0) to 4.4 x 10(4)CFU cm-2 for moulds and yeasts; < 0.3 to > 32.0 most probable number/cm² (MPN cm-2) for total and thermotolerant coliforms and Escherichia coli. Salmonella sp. and Listeria spp. were not found in any of the carcasses. Most carcasses presented low counts for all microorganisms. Overall results may be explained by the small size of the industry where the study was taken. Results suggest that good microbiological quality lamb meat is possible to be obtained, but improvement in hygienic-sanitary conditions is still required.


1977 ◽  
Vol 40 (11) ◽  
pp. 790-794 ◽  
Author(s):  
JAMES F. FOSTER ◽  
JAMES L. FOWLER ◽  
WARREN C. LADIGES

The microbiological quality of 150 units of raw ground beef obtained from a local retail store was determined. The range of aerobic plate counts was from 6.9 × 104 to 8.3 × 107/g. By using the most probable number method 96.7% of the 150 units were positive for coliforms, 94.7% for Escherichia coli and 61.3% for Staphylococcus aureus. By the plate methods, 99.3% of the units were positive for fecal streptococci and 56% were positive for Clostridium perfringens. No salmonellae were isolated. Aerobic and anaerobic organisms were isolated and identified. E. coli was the most frequently isolated aerobe followed by organisms in the Klebsiella-Enterobacter group. Among the anaerobic isolates, C. perfringens was the organism most frequently encountered.


Author(s):  
B. G. Jega ◽  
O. O. Adebisi ◽  
S. S. Manga

This study aimed to evaluate the impact of abattoir effluent on microbiological quality of the receiving Tagangu River and the susceptibility of the isolates to commonly-used antibiotics. The most probable number (MPN) as well as the Kirby-Bauer method of antibiotic susceptibility test were used and demonstrated the total heterotrophic bacteria as well as Escherichia coli O157:H7 numbers in a total of 30 water samples collected over a period of three months at three strategic points of the river. In accordance with CLSI guidelines, four out of eight bacteria (Enterobacter sp., Pseudomonas aeruginosa, Proteus vulgaris and Citrobacter sp.) isolated, demonstrated multiple antibiotic resistance (MAR) against at least three out of septrin, chloramphenicol, amoxicillin, augmentin, gentamicin, tarivid and streptomycin. All the isolates (Escherichia coli, Klebsiella pneumoniae, Enterobacter sp., Pseudomonas aeruginosa, Proteus vulgaris, Citrobacter sp., Serratia marcescens and Aerobacter aerogenes) showed either high or intermediate susceptibility to sparfloxacin, ciprofloxacin and pefloxacin. The findings indicated that the river has been heavily polluted with the effluent discharges and did not meet any of the WHO guidelines for natural water sources fit for irrigation or other domestic purposes. As such, indiscriminate discharge of abattoir effluent could impact on the microbiological quality and promote increased incidence of multiple antibiotic resistant bacteria in a receiving river.


2010 ◽  
Vol 1 (1) ◽  
pp. 25
Author(s):  
Dayane Aparecida dos Santos ◽  
Angela Kwiatkowski ◽  
Marcos Vieira da Silva ◽  
Dalany Menezes ◽  
Lucimar Peres de Moura Pontara

<p>Monitoring the microbiology of honey is necessary to ensure its final quality. The microbial contamination is a danger to public health, a major concern for the surveillance agency. The objective of this study was to evaluate the microbiological quality of honey produced in the cerrado region, Mato Grosso State. The apiary was installed in the town of Conquista D'Oeste city, a total of 30 boxes of honey covered with asbestos tile and exposed to the sun. The honey was collected in November of 2008. The physical and chemical analysis were carried out: moisture, total soluble solids (TSS) and pH. Microbiological analysis were: mesophilic bacteria facultative aerobic, yeast and mold, Staphylococcus, the most probable number (MPN) of coliforms at 35&ordm;C and 45&ordm;C, and the presence of Salmonella sp. The methods used followed the directions of the Normative Instruction no. 62, August 23, 2003 of Minist&eacute;rio da Agricultura, Pecu&aacute;ria e Abastecimento - MAPA. The pH value resulted in 3.80, SST at 81.5 and humidity at 17 %. Microbiological analysis showed no presence of Salmonella, Staphylococcus and yeast. The count of facultative aerobic bacteria was 5.0 x 101, the two groups of coliforms in NMP was &lt;3.0, and 3.0 x 101 mold. The samples of honey studied showed appropriate microbiological quality.</p><p>&nbsp;</p><p><span>DOI:&nbsp;</span><a href="http://dx.doi.org/10.14685/rebrapa.v4i1.102"><span>http://dx.doi.org/10.14685/rebrapa.v1i1.5</span></a><span>&nbsp;</span></p><p>&nbsp;</p>


1991 ◽  
Vol 74 (4) ◽  
pp. 635-648 ◽  
Author(s):  
Michael S Curiale ◽  
Therese Sons ◽  
Dawn Mclver ◽  
J Sue McAllister ◽  
Barbara Halsey ◽  
...  

Abstract Rehydratable dry-film plating methods for total coliforms and Escherichia coll In foods have been compared to the AOAC most probable number methods. Fourteen laboratories participated In the collaborative study. Three coliform and £. coll levels In 6 samples of 4 product types (flour, nuts, cheese, and beef with gravy) and in 3 samples of 2 product types (mushrooms and raw turkey) were tested In duplicate by the participants. The mean log counts for the 3 methods were comparable. In general, the repeatability and reproducibility variances of the plating methods were as good as or better than that of the MPN method. The method has been adopted official first action by AOAC.


1994 ◽  
Vol 77 (1) ◽  
pp. 58-63 ◽  
Author(s):  
Philip T Feldsine ◽  
Maria T Falbo-Nelson ◽  
David L Hustead

Abstract The ColiComplete® substrate-supporting disc (SSD) method for simultaneous confirmed total coliform count and Escherichia coli determination in all foods was compared with the AOAC most probable number (MPN) methods 966.23 and 966.24. In this comparative study, 20 water and food types were analyzed; 7 of these foods were naturally contaminated with coliform bacteria, 6 food types were naturally contaminated with E. coli, and the remaining foods were inoculated with coliform bacteria and/or E. coli. Data were analyzed separately for total coliform bacteria and for E. coli. Mean log MPN counts were determined by the SSD method and the appropriate AOAC MPN procedure. Results were then analyzed for mean log MPN differences and variance, according to methods described by AOAC INTERNATIONAL Results for both total conforms and E. coli indicate that the SSD method is equivalent to or better than AOAC MPN methods 966.23 and 966.24.


2014 ◽  
Vol 4 (4) ◽  
pp. 604-611
Author(s):  
Amanda S. Brand ◽  
Jo M. Barnes

The increase in numbers and contamination levels of faecally polluted water has resulted in shifts worldwide towards methods which enumerate faecal indicator bacteria faster. Rapid methods enable more timely remedial and preventative actions which protect the health of water users. However, especially in the developing world, straightforward methods are also preferred as they reduce the requirement for highly qualified analysts. This study investigates the feasibility of using the rapid, semi-automated enzyme substrate test Colilert-18® instead of multiple-tube fermentation (MTF) in total coliform and Escherichia coli enumeration for South African river water, as one example of a surface water source carrying considerable faecal pollution, which needs monitoring. Spearman rank correlation coefficients (ρ) of 0.83 and 0.86 were obtained for total coliforms and E. coli respectively, indicating Colilert-18® performed acceptably in the pollution ranges encountered. A Bland–Altman plot further revealed that Colilert-18® showed no significant difference (p &gt; 0.05) from MTF values below 100,000 E. coli most probable number/100 mL (estimated true value). Above this level Colilert-18® was found to progressively underestimate E. coli. This inadequacy of Colilert-18® was considered acceptable from a health risk assessment viewpoint as such high counts should have sounded the alarm for preventative and corrective action irrespective of method inaccuracy.


2019 ◽  
Vol 11 (2) ◽  
pp. 47-56
Author(s):  
Erica Guedes Celestino ◽  
Micheline Thaís Santos ◽  
Sybelle Georgia Silva ◽  
Tania Marta Carvalho dos Santos ◽  
Elizabeth Simões do Amaral Alves ◽  
...  

The objective of this study was to verify the microbiological quality of raw and pasteurized goat milk and produced in Alagoas state, Brazil. Was carried out three interval collect of pasteurized and raw milk and the samples taken to the laboratory. All samples were subjected to aerobic mesophilic microorganisms counting, psychrotrophic microorganisms, determination of the most probable number (MPN) of total coliforms and thermotolerant microorganisms. For analysis, samples were plated on specific medium (Baird-Parker Agar Base himedia M043) and incubated at 37 °C for 24h. To Salmonella sp. detection was used plating the medium Salmonella Shigella agar. The presence of coliforms at 35 °C was detected in all samples as well as 45 °C except to first sample. To the pasteurized milk was found to coliforms at 35 °C and 45 °C in the second and third samples. Only in the second test was checked the presence of mesofilic bacteria. We have not found samples contaminated with microorganisms psychrotrophic, Salmonella sp. and Staphylococcus sp. According to the obtained results the quality of collected milk has unacceptable conditions of consumption compared to coliform counts, according to the parameters established by law.


2007 ◽  
Vol 53 (6) ◽  
pp. 798-801 ◽  
Author(s):  
Tamara Garcia-Armisen ◽  
Josué Prats ◽  
Pierre Servais

Fecal coliforms (FC) counts were compared with Escherichia coli counts in differently contaminated freshwater samples (n = 166). FC were enumerated by plate count on triphenyl 2,3,5-tetrazolium chloride Tergitol medium. Escherichia coli were enumerated by the most probable number microplate method based on the detection of glucuronidase activity. FC and E. coli counts were highly correlated; an average E. coli/FC ratio equal to 0.77 was found, meaning that on average, 77% of FC were E. coli. Knowing the E. coli/FC ratio allows us to convert the historical microbiological quality data expressed in FC counts into E. coli abundance and thus to compare with present and future monitoring data that are (or will be) based on E. coli enumeration.


Sign in / Sign up

Export Citation Format

Share Document