Quantification of Trabecular-Iris Contact and its Prevalence by Optical Coherence Tomography in a Healthy Caucasian Population

2016 ◽  
Vol 27 (4) ◽  
pp. 417-422 ◽  
Author(s):  
José Ignacio Fernández-Vigo ◽  
Lucía De-Pablo-Gómez-De-Liaño ◽  
Cristina Fernández-Vigo ◽  
Inés Sánchez-Guillén ◽  
Enrique Santos-Bueso ◽  
...  

Purpose To determine the prevalence of trabecular-iris contact (TIC) and quantify this contact in healthy Caucasian individuals using Fourier-domain optical coherence tomography (FD-OCT). Methods For this cross-sectional study, 2,012 eyes of 1,006 healthy subjects were recruited among individuals undergoing a routine ophthalmologic checkup. In each participant, age, sex, intraocular pressure, and spherical refractive error were first recorded along with anterior chamber depth and volume, central corneal thickness measured with the Pentacam, and axial length with the IOLMaster. Anterior chamber angle variables and the presence of TIC in the horizontal quadrants were determined by anterior segment FD-OCT (RTVue 100®). When TIC was observed, TIC length (TICL) and its percentage in relation to the length of the trabecular meshwork (TICL percentage) were also measured. Results Trabecular-iris contact in the horizontal quadrants was observed in 34 eyes of 25 patients, representing 1.6% of the total number of eyes examined. In this subgroup of individuals, mean age was 55.8 years, 84% were women, and spherical refractive error ranged from -0.25 to 8.25 D. Eyes with TIC showed an angle width of less than 23.2 degrees and axial length shorter than 23.7 mm. Mean TICL was 239 ± 79 μm (103-495 μm) and mean TICL percentage was 46.9% ± 13.9% (17.2%-76.3%). Conclusions The prevalence of TIC was low in this population. Fourier-domain optical coherence tomography emerged as useful to assess its prevalence and quantify the extent of TIC.

2019 ◽  
Vol 47 (12) ◽  
pp. 5950-5956 ◽  
Author(s):  
Yiyong Qian ◽  
Lin Liu ◽  
Yuehui Shi ◽  
Minli Wang ◽  
Min Li ◽  
...  

Objective To investigate the clinical indications of ultrasound biomicroscopy (UBM) and anterior segment optical coherence tomography (AS-OCT) in eyes with inflammatory glaucoma. Methods Sixteen patients (16 eyes) with inflammatory glaucoma were analysed retrospectively. All of the subjects underwent UBM and AS-OCT scans, measuring the following parameters: central corneal thickness (CCT), central anterior chamber depth (ACD), angle-opening distance (AOD500), and trabecular-iris angle (TIA500) in four quadrants. Results Both the UBM and AS-OCT generated detailed, high-resolution images of the anterior segments of the eyes with inflammatory glaucoma. Moreover, the UBM and AS-OCT exhibited statistically similar measurement results for all of the indices. A Bland–Altman analysis showed a high level of agreement between the two imaging techniques. Additionally, the UBM was able to visualize the ciliary body and pars plana, while the cells and the flare in the anterior chamber appeared more pronounced in the UBM images. Conclusions Both the UBM and AS-OCT are useful tools for anterior segment imaging and taking measurements needed for evaluating inflammatory glaucoma. The AS-OCT has the advantages of being noninvasive and fast, whereas the UBM is presently unparalleled in the visualization of the ciliary body and pars plana.


2019 ◽  
Vol 104 (6) ◽  
pp. 795-799 ◽  
Author(s):  
Natalia Porporato ◽  
Mani Baskaran ◽  
Tin A Tun ◽  
Rehena Sultana ◽  
Marcus Tan ◽  
...  

Background/aimsAlthough being a more objective tool for assessment and follow-up of angle closure, reliability studies have reported a moderate diagnostic performance for anterior segment optical coherence tomography (OCT) technologies when comparing with gonioscopy as the reference standard. We aim to determine factors associated with diagnostic disagreement in angle closure when assessed by anterior segment swept source OCT (SS-OCT, CASIA SS-1000; Tomey, Nagoya, Japan) and gonioscopy.MethodsCross-sectional study. A total of 2027 phakic subjects aged ≥50 years, with no relevant previous ophthalmic history, were consecutively recruited from a community polyclinic in Singapore. Gonioscopy and SS-OCT (128 radial scans) for the entire circumference of the angle were performed for each subject. A two-quadrant closed gonioscopic definition was used. On SS-OCT images, angle closure was defined as iridotrabecular contact (ITC) to the extent of ≥35%, ≥50% and ≥75% of the circumferential angle. Diagnostic disagreements between both methods, that is, false positives or overcalls and false negatives or undercalls were defined, respectively, as gonioscopic open/closed angles inversely assessed as closed/open by SS-OCT.ResultsTwo hundred and seventy-two (14.7%) resulted in overcall results (false positives) when ≥50% of the angle circumference was closed using SS-OCT. These eyes had significantly wider (anterior chamber width, 11.7 vs 11.6 mm, p<0.001) and deeper (anterior chamber depth (ACD), 2.4 vs 2.2 mm, p<0.001) anterior chambers than eyes assessed by both methods as closed (true positives). Deeper ACD (OR 9.31) and lower lens vault (LV) (OR 0.04) were significantly associated with a false positive diagnosis in the multivariate analysis. Most of these cases had short (52.6%) or irregular (39%) ITC in SS-OCT images.ConclusionsWe found that anterior chamber dimensions, determined by ACD and LV, were factors significantly associated with diagnostic disagreement between anterior segment SS-OCT and gonioscopy in angle closure assessment.


2019 ◽  
Author(s):  
Ziyan Yu ◽  
Ting Huang ◽  
Qiao Yu ◽  
Jun Kong ◽  
Bo Qu

Abstract Purpose To compare anterior chamber depth (ACD) and central corneal thickness (CCT) measurements by anterior segment optical coherence tomography (AS-OCT), Lenstar and ultrasound biomicroscopy (UBM). Methods A retrospective cross section study. A total of 83 eyes from 54 patients were included. Central corneal thickness (CCT) and anterior chamber depth (ACD) values obtained from three devices (AS-OCT, Lenstar and UBM) were recorded. All patients were collected from Oct. 2015 to Aug. 2016 in the Fourth Affiliated Hospital of China Medical University. Differences of these three devices (ACD and CCT) were statistically analyzed by randomized blocks analysis. Pearson correlative analysis and Bland-Altman analysis were used to compare the correlation and agreement. Results There’s no significant difference in measuring ACD by Lenstar and UBM (P>0.05), but there were significant differences in other two groups (AS-OCT and UBM, AS-OCT and Lenstar) (P<0.05). There were significant differences in the mean CCT measured by the three devices (P<0.05). There were high correlation in measuring ACD (all P<0.001, r1=0.928,r2=0.982,r3=0.932, respectively), and CCT(all P<0.001,r1=0.957,r2=0.949,r3=0.928, respectively). Conclusion AS-OCT, Lenstar and UBM yielded comparable results and are all can be used interchangeably for anterior segment measurements.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Kumiko Kato ◽  
Mineo Kondo ◽  
Maki Takeuchi ◽  
Koji Hirano

Abstract To determine the parameters of the anterior segment of eyes that are significantly associated with the refractive error in healthy young Japanese university students. This was a cross-sectional observational study of 229 healthy Japanese university students (men: women,147:82) whose age ranged between 20 to 29 years. Univariate and multivariate linear regression analyses were performed to identify the factors that were significantly correlated with the refractive error. The independent variables included age, sex, axial length, anterior chamber depth, corneal diameter, curvature of anterior surface of cornea, and central corneal thickness. The mean refractive error (spherical equivalent) was −4.1 ± 2.7 diopters (D) with a range of −12.5 to +0.5 D, and the mean axial length was 25.4 ± 1.3 mm with a range of 22.4 to 29.0 mm. Pearson univariate correlation analysis found that the refractive error was significantly and negatively correlated with the axial length (R = −0.82, P < 0.001), deeper anterior chamber (R = −0.30, P < 0.001), and larger corneal diameter (R = −0.21, P = 0.001). Multiple regression analysis showed that the refractive error was significantly associated with a longer axial length (P < 0.001), a deeper anterior chamber (P < 0.001), and a flatter corneal curvature (P < 0.001).The biometric values of the anterior segment of the eyes should make the eye more hyperopic which would reduce the myopia-inducing lengthening of the axial length.


2021 ◽  
Author(s):  
Mohamed Salah El-Din Mahmoud ◽  
Nosiba Essam ◽  
Layla Mohamed Hammouda ◽  
Ahmed Shawkat Mohamed

Abstract Purpose: The study aims is to detect primary angle-closure glaucoma (PACG) suspects using both anterior segment optical coherence tomography (AS-OCT) and Scheimpflug imaging. Methods: A prospective cross-sectional observational study on forty PACG suspect patients with a range of ages from 20 to 70 years. Angle imaging by AS-OCT (Optovue Inc., Fairmont, CA) with study parameters in the superior, inferior, nasal, and temporal quadrants were anterior chamber angle (ACA), angle opening distance at 750 µm (AOD750), and trabecular-iris space area at 750 μm (TISA). Also, angle imaging using Pentacam (Oculus Optikgeräte GmbH, Wetzlar, Germany) with study parameters were the anterior chamber angle (ACA), anterior chamber depth (ACD) and, anterior chamber volume (ACV). The angle evaluation was done before and after the mydriatic test.Results: As regarding AS-OCT, after the mydriatic test, we noticed a decrease in all parameters measured, some decreased significantly while others did not. A significant decrease was noticed in ACA (TIA750) in all quadrants (P value<0.001in nasal, 0.001in superior &temporal, 0.003 in inferior) and in TISA750 in the nasal quadrant only (P-value 0.004). AOD750 and TISA750 in the remaining quadrants also decreased but not significantly as ACA. As regarding Pentacam, all parameters decreased after the mydriatic test. ACA (P-value <0.001) and ACD (P-value 0.004) showed significant statistical decrease but ACV showed statistically non-significant decrease (P-value 0.558).Conclusions: AS-OCT and Pentacam are reliable investigations for the detection of PACG suspects which needs more close follow-up for a possible increase in IOP.


Author(s):  
Alireza Khodabande ◽  
Massood Mohammadi ◽  
Hamid Riazi-Esfahani ◽  
Shahab Karami ◽  
Massood Mirghorbani ◽  
...  

Abstract Background To evaluate changes in anterior segment morphology on anterior segment optical coherence tomography (AS-OCT) following pars plana vitrectomy (PPV) without tamponade. Methods Patients who underwent PPV without tamponade for epiretinal membrane were evaluated. Eligible patients underwent intraocular pressure (IOP) measurement and AS-OCT preoperatively as well as 1 month and 6 months post-operatively. Anterior chamber width (ACW), anterior chamber depth (ACD), trabecular iris angle (TIA), angle opening distance at 500 and 750 µm (AOD), and trabecular iris space area at 500 and 750 µm (TISA) at four quadrants were recorded and analyzed. Additionally, the mean values of TIA (MTIA), AOD (MAOD), and TISA (MTISA) for each eye (mean of four quadrants) were analyzed. Results 23 patients completed the study. The mean age of participants was 56.4 ± 3.6 years of age and 13/23 (56%) were female. Mean IOP of patients was 18.1 ± 1.1, 18.3 ± 1.1, and 18.1 ± 1.2 preoperatively,1 month post-operatively, and 6 months post-operatively, respectively. (p = 0.83). No difference was detected post-operatively in measurements of ACW, ACD, MTIA, MAOD500, MAOD750, MTISA500, and MTISA750. Conclusion Pars plana vitrectomy without tamponade was not associated with changes in anterior chamber morphology.


2016 ◽  
Vol 2016 ◽  
pp. 1-4 ◽  
Author(s):  
Ercan Ozsoy ◽  
Abuzer Gunduz ◽  
Ersin Ersan Demirel ◽  
Tongabay Cumurcu

Purpose. To evaluate anterior segment’s structures by Pentacam in patients with tilted disc syndrome (TDS).Methods. Group 1 included forty-six eyes of forty-six patients who have the TDS. Group 2 including forty-six eyes of forty-six cases was the control group which was equal to the study group in age, gender, and refraction. A complete ophthalmic examination was performed in both groups. All cases were evaluated by Pentacam. The axial length (AL) of eyes was measured by ultrasound. Quantitative data obtained from these measurements were compared between two groups.Results. There was no statistically significant difference for age, gender, axial length, and spherical equivalent measurements between two groups (p=0.625,p=0.830,p=0.234, andp=0.850). There was a statistically significant difference for central corneal thickness (CCT), corneal volume (CV), anterior chamber angle (ACA), and pupil size measurements between two groups (p=0.001,p=0.0001,p=0.003, andp=0.001). Also, there was no statistically significant difference for anterior chamber depth (ACD), anterior chamber volume (ACV), and lens thickness (LT) measurements between two groups (p=0.130,p=0.910, andp=0.057).Conclusion. We determined that CCT was thinner, CV was less, and ACA was narrower in patients with TDS. There are some changes in the anterior segment of the eyes with tilted disc.


2020 ◽  
pp. bjophthalmol-2019-315445
Author(s):  
Alexei N Kulikov ◽  
Dmitrii S Maltsev ◽  
Alina A Kazak ◽  
Maria A Burnasheva

PurposeTo study the correlation between intraocular pressure (IOP) reduction and the number of hyper-reflective particles appearing in the anterior chamber following selective laser trabeculoplasty (SLT).Material and methodsIn this prospective interventional study, we included primary open-angle glaucoma patients. All participants received a standardised SLT session, which consisted of 100 pulses of 0.9 mJ over 360°. Anterior segment optical coherence tomography (4×4 mm volume scan, 101 horizontal cross-sectional scans) and applanation tonometry were performed before SLT and 15 min, 1 day, 1 week, 1 month and 3 months after. Particles were counted on cross-sectional scans using a standardised algorithm.ResultsIn this study, we included 25 patients (25 eyes), 14 males and 11 females, with a mean age of 68.9±10.5 and baseline IOP of 21.4±4.5 mm Hg. IOP at month 1 and month 3 after SLT was 18.0±4.0 and 17.4±3.3 mm Hg, respectively. The mean number of anterior chamber particles before and 15 min after SLT was 0.62±0.2 and 7.1±2.0 particles/mm2, respectively (p=0.036). There was a statistically significant correlation between the mean number of anterior chamber particles 15 min after SLT and IOP reduction at 1 month (r=0.62, p=0.03) and 3 months (r=0.71, p=0.01).ConclusionThe number of the anterior chamber particles graded using anterior segment optical coherence tomography after the procedure correlates with the IOP-lowering effect of SLT.


2019 ◽  
Author(s):  
Man Hu ◽  
Qian Zheng ◽  
Zhangliang Li ◽  
Pingjun Chang ◽  
Yun-e Zhao

Abstract Background To assess the changes of anterior chamber angle in patients with shallow anterior chamber and normal anterior chamber after phacoemulsification and intraocular lens implantation (IOL) using anterior segment swept-source optical coherence tomography (AS-SS-OCT). Methods This was a prospective case control study; 60 eyes of 60 patients who underwent cataract surgery. Based on anterior chamber depth (ACD) and gonioscopy findings, the eyes were classified into two groups, shallow anterior chamber group (30 eyes) and normal anterior chamber group (30 eyes). AS-SS-OCT was used to measure ACD and angle parameters angle opening distance (AOD), angle recess area (ARA), trabecular iris space area(TISA), and trabecular iris angle (TIA). Serial changes in each group were measured before and 3 months after phacoemulsification and IOL, and the differences between the two groups were compared. Results All angle parameters including ACD, AOD, ARA, TISA, and TIA in both groups at 3 months after cataract surgery were significantly different from the preoperative values (p<0.01). In addition, we found significant differences of all angle parameters between groups of shallow anterior chamber (SAC) and normal anterior chamber (NAC) (All P< 0.05). Besides, the TISA750 in superior quadrant and anterior chamber volume (ACV) were significantly smaller in the group of SAC than those in the group of NAC (P = 0.041 and 0.002, respectively). Conclusions The parameters of anterior chamber increased significantly in both two groups but not increase to the same extent 3 months after phacoemulsification. Iris thickening may also be one of the narrow angle factors,not just age-related lens thickening.


Sign in / Sign up

Export Citation Format

Share Document