Phacoemulsification with Toric IOL Implantation in Alport Syndrome with Anterior Lenticonus having Spontaneously Ruptured Anterior Capsule

2015 ◽  
Vol 25 (5) ◽  
pp. e78-e80 ◽  
Author(s):  
Niraj Agrawal ◽  
Durga Prasad Nayak ◽  
Aravind Haripriya ◽  
Puja Bhuwania
2021 ◽  
Vol 0 (0) ◽  
pp. 0-0
Author(s):  
mohamed baz ◽  
Essam El Din Shoheib Ahmed ◽  
Ashraf El Shayeb ◽  
Walid Abbdelghaffar
Keyword(s):  

2020 ◽  
Author(s):  
Da young Shin ◽  
Ho Sik Hwang ◽  
Hyun Seung Kim ◽  
Man Soo Kim ◽  
Eun Chul Kim

Abstract Background: To analyze and compare the clinical results of toric intraocular lens (IOL) and monofocal IOL implantation when the target refraction value is determined -3 diopter (D) in cataract patients with corneal astigmatism >1.5 diopters (D).Methods: We performed a retrospective chart review for patients with corneal astigmatism >1.5D who underwent cataract surgery and their target refraction is determined -3D. 100 eyes (100 patients; monofocal IOL, 60; toric IOL, 40) were enrolled in the current study. Near and distant uncorrected visual acuity (UCVA), corrected VA, spherical equivalent and refractive, corneal astigmatism were evaluated before and after surgery.Results: The near UCVA of the toric IOL group (0.26±0.33) after cataract surgery was significantly better than that of the monofocal IOL group (0.48±0.32) (p=0.030). The distant UCVA of the toric IOL group (0.38 ± 0.14) was also significantly better than that of the monofocal IOL group (0.55 ± 0.22) (p = 0.026). There were no significant intergroup differences in postoperative best-corrected visual acuity (p = 0.710) and mean spherical equivalent (p = 0.465). In the toric IOL group, postoperative refractive astigmatism was -0.80 ± 0.46D and postoperative corneal astigmatism was -1.50 ± 0.62D, whereas the corresponding values in the monofocal IOL group were -1.65 ± 0.77D and -1.45 ± 0.64D; residual refractive astigmatism was significantly lower with toric IOL implantation compared with monofocal IOL implantation (p = 0.001). Conclusions: When myopic refraction such as -3D was determined as the target power in patients with corneal astigmatism, toric IOL implantation led to excellent improvement in both near and distant UCVA.


2017 ◽  
Vol 1 (1) ◽  
pp. oapoc.0000008 ◽  
Author(s):  
Vincenzo Scorcia ◽  
Andrea Lucisano ◽  
Vincenzo Savoca Corona ◽  
Valentina De Luca ◽  
Adriano Carnevali ◽  
...  

Purpose To evaluate the outcomes of deep anterior lamellar keratoplasty (DALK) followed by phacoemulsification and toric intraocular lens (IOL) implantation for the treatment of concomitant stromal disease and cataract. Methods In this retrospective non-comparative interventional case series, ten eyes affected by stromal disease and cataract underwent DALK followed by phacoemulsification with toric IOL implantation after a minimum period of 5 months from complete suture removal. In each case, topographic astigmatism, refraction, visual acuity, and endothelial cell density were recorded before DALK and 1, 6, and 12 months after cataract surgery. In addition, IOL rotation was evaluated using anterior segment optical coherence tomography. Results Big-bubble DALK was performed in all eyes but one that received manual dissection. Topographic astigmatism averaged 5.6 ± 2.2 diopters (D) after suture removal; refractive astigmatism decreased to 0.55 ± 0.61 D as early as one month after cataract surgery and did not change substantially throughout the follow-up period. In all patients, one month after phacoemulsification uncorrected and best spectacle-corrected visual acuity were, respectively, ≥20/40 and ≥20/25 with a residual spherical equivalent of 0.00 ± 0.84 D. At the latest follow-up visit, in all cases the IOL rotation was ≤5 degrees from the intended position and the endothelial cell loss within 8.5%. No complications were recorded. Conclusions DALK followed by phacoemulsification with toric IOL implantation optimizes visual and refractive outcomes in patients with concomitant stromal disease and cataract. In comparison with a combined procedure, the sequential approach offers better predictability of the postoperative refraction in the absence of an increased risk of complications.


2007 ◽  
Vol 33 (6) ◽  
pp. 1127-1130 ◽  
Author(s):  
Mohammad Ali Zare ◽  
Mohammad Taher Rajabi ◽  
Mehdi Nili-Ahmadabadi ◽  
Syed Jafar Oskouee ◽  
Sasan Moghimi

2008 ◽  
Vol 36 (6) ◽  
pp. 1440-1444 ◽  
Author(s):  
YB Liu ◽  
SJ Tan ◽  
ZY Sun ◽  
X Li ◽  
BY Huang ◽  
...  

The case of a 29-year-old man is reported who presented with a gradually progressive, painless decrease in vision over 10 years. Anterior segment examination with a slit lamp revealed anterior lenticonus in both eyes. The patient had previously been diagnosed with bilateral sensorineural deafness, however investigations revealed microscopic haematuria and renal insufficiency that subsequently led to a diagnosis of classical Alport syndrome. Since the patient's quality of vision was severely affected by the bulging anterior lens capsule, surgical treatment was required. Clear lens phacoemulsification with continuous curvilinear capsulorhexis and foldable intraocular lens implantation were performed in each eye 2 days apart. One week after surgery, visual acuity was excellent in both eyes. Clear lens phacoemulsification with continuous curvilinear capsulorhexis and foldable intraocular lens implantation was a safe and effective therapeutic choice in this patient for the management of anterior lenticonus due to Alport syndrome.


2020 ◽  
Author(s):  
Hye Ji Kwon ◽  
Hun Lee ◽  
Jin Ah Lee ◽  
Jae Yong Kim ◽  
Hungwon Tchah

Abstract Objectives To compare the efficacy of astigmatic correction between simultaneous femtosecond laser-assisted intrastromal arcuate keratotomy (AK) combined with femtosecond laser-assisted cataract surgery (FLACS) and toric intraocular lens (IOL) implantation during cataract surgery in moderate astigmatism. Design: Retrospective observational study, tertiary care medical center Methods We retrospectively reviewed medical records of patients who underwent astigmatic correction via femtosecond laser-assisted intrastromal AK (AK group; 27 eyes of 27 patients) with FLACS or toric IOL implantation (toric IOL group; 21 eyes of 21 patients). All patients had senile cataracts with corneal astigmatism ranging from + 1.00 to + 2.00 diopters (D) before cataract surgery. We measured visual acuity, intraocular pressure, automated keratometry, manifest refraction and topography preoperatively and at 1-day, 1-month, 3-month, and 6-month postoperatively. Results Refractive astigmatism was significantly decreased in both groups. The mean preoperative and 6-month postoperative refractive astigmatism were 1.85 ± 1.07 and 0.99 ± 0.51 D, respectively, in the AK group (P = 0.028), and 1.84 ± 0.81 and 0.68 ± 0.21 D, respectively, in the toric IOL group (P < 0.001). There was no significant difference in refractive astigmatism between the two groups at 6-month postoperatively (0.99 ± 0.51 vs 0.68 ± 0.21 D, P = 0.057). At 6-month postoperatively, parameters for vector analysis of refractive astigmatism showed no statistical difference between the two groups. Corneal astigmatism was significantly decreased in the AK group. There was significant difference in corneal astigmatism from topography and automated keratometer between the two groups at 6-month postoperatively (0.94 ± 0.40 vs 1.53 ± 0.46 D, P = 0.018 for topography and 0.98 ± 0.69 vs 1.37 ± 0.41 D, P = 0.032 for automated keratometer). Conclusions Femtosecond laser-assisted intrastromal AK in FLACS could be an effective procedure for reducing astigmatism as well as toric IOL implantation in cataract surgery.


Sign in / Sign up

Export Citation Format

Share Document