scholarly journals The use of underactuation in prosthetic grasping

2011 ◽  
Vol 2 (1) ◽  
pp. 27-32 ◽  
Author(s):  
P. J. Kyberd ◽  
A. Clawson ◽  
B. Jones

Abstract. Underactuation as a method of driving prosthetic hands has a long history. The pragmatic requirements of such a device to be light enough to be worn and used regularly have meant that any multi degree of freedom prosthetic hand must have fewer actuators than the usable degrees of freedom. Aesthetics ensures that while the hand needs five fingers, five actuators have considerable mass, and only in recent years has it even been possible to construct a practical anthropomorphic hand with five motors. Thus there is an important trade off as to which fingers are driven, and which joints on which fingers are actuated, and how the forces are distributed to create a functional device. This paper outlines some of the historical solutions created for this problem and includes those designs of recent years that are now beginning to be used in the commercial environment. This paper was presented at the IFToMM/ASME International Workshop on Underactuated Grasping (UG2010), 19 August 2010, Montréal, Canada.

2018 ◽  
Vol 3 (23) ◽  
pp. eaau5543 ◽  
Author(s):  
Kevin W. O’Brien ◽  
Patricia A. Xu ◽  
David J. Levine ◽  
Cameron A. Aubin ◽  
Ho-Jung Yang ◽  
...  

The force, speed, dexterity, and compact size required of prosthetic hands present extreme design challenges for engineers. Current prosthetics rely on high-quality motors to achieve adequate precision, force, and speed in a small enough form factor with the trade-off of high cost. We present a simple, compact, and cost-effective continuously variable transmission produced via projection stereolithography. Our transmission, which we call an elastomeric passive transmission (EPT), is a polyurethane composite cylinder that autonomously adjusts its radius based on the tension in a wire spooled around it. We integrated six of these EPTs into a three-dimensionally printed soft prosthetic hand with six active degrees of freedom. Our EPTs provided the prosthetic hand with about three times increase in grip force without compromising flexion speed. This increased performance leads to finger closing speeds of ~0.5 seconds (average radial velocity, ~180 degrees second−1) and maximum fingertip forces of ~32 newtons per finger.


2019 ◽  
Vol 9 (20) ◽  
pp. 4203 ◽  
Author(s):  
Xiaobei Jing ◽  
Xu Yong ◽  
Yinlai Jiang ◽  
Guanglin Li ◽  
Hiroshi Yokoi

Most prosthetic hands adopt an under-actuated mechanism to achieve dexterous motion performance with a lightweight and anthropomorphic design. Many have been verified in laboratories, and some have already been commercialized. However, a trade-off exists between the dexterity and the light weight of such prosthetic hands. In general, current commercially available prosthetic hands usually consider one aspect at the expense of the other, such as obtaining diversiform hand motions but an increased weight, or achieving lightweight design but with limited motion functions. This study attempts to attain a balance between the two factors, by realizing diversiform hand motions while reducing the weight as far as possible. An anthropomorphic prosthetic hand is proposed with only three servomotors embedded in a human-sized palm, with multiple functions, such as a stable/adaptive grasp and passive hyperextension. The proposed hand can achieve 13 grasp types with over 80% of the grasp motions under the Cutkosky taxonomy, while it weighs only 132.5 g, at less than 36% of the prosthesis weight limitation based on the study of Kay et al.


2011 ◽  
Vol 36 (1) ◽  
pp. 33-38 ◽  
Author(s):  
Peter J Kyberd

Background: The addition of a passive wrist to a single degree of freedom prosthesis has an effect on its functionality. The amount of impact is undetermined.Objectives: To measure the grasping function of a commercial single degree of freedom hands with and without two forms of passive wrist flexor.Study Design: Form-board and timed tasks.Method: Repeated measures with a single subject using a validated assessment tool. The test measured the function of one conventional, single axis, powered hand controlled by the same myocontroller format. It was used in conjunction with a passive three position wrist flexor, a wrist with compliance in the flex/extend and radial/ulnar deviation and compared with a hand without these axes.Results: The overall functional score of the hand alone was 80 out of 100. The use of a wrist flexion unit resulted in a higher score (83) and the compliant wrist achieved a score of 79. The addition of a wrist allowed improved performance in Power, Lateral and Tips grips for both wrist designs, in addition the Extension grip was improved with the compliant wrist.Conclusion: Wrist flexion had a positive impact on the functional score. It enabled some tasks to be performed quicker and with less difficulty.Clinical relevanceThe majority of prosthetic hands have pro/supination yet there is little evidence about what impact this, or any other motion at the wrist, has on the overall functional capabilities of a prosthetic hand (i.e. grip). A commercial myoelectric prosthetic hand when used with and without two different wrist designs can potentially improve grip performance.


Author(s):  
Qixin Zhu ◽  
Lei Xiong ◽  
Hongli Liu ◽  
Yonghong Zhu ◽  
Guoping Zhang

Background: The conventional method using one-degree-of-freedom (1DOF) controller for Permanent Magnet Synchronous Motor (PMSM) servo system has the trade-off problem between the dynamic performance and the robustness. Methods: In this paper, by using H∞ control theory, a novel robust two-degree-of-freedom (2DOF) controller has been proposed to improve the position control performance of PMSM servo system. Using robust control theory and 2DOF control theory, a H∞ robust position controller has been designed and discussed in detail. Results: The trade-off problem between the dynamic performance and robustness which exists in one-degree-of-freedom (1DOF) control can be dealt with by the application of 2DOF control theory. Then, through H∞ control theory, the design of robust position controller can be translated to H∞ robust standard design problem. Moreover, the control system with robust controller has been proved to be stable. Conclusion: Further simulation results demonstrate that compared with the conventional PID control, the designed control system has better robustness and attenuation to the disturbance of load impact.


Sensors ◽  
2021 ◽  
Vol 21 (11) ◽  
pp. 3740
Author(s):  
Olafur Oddbjornsson ◽  
Panos Kloukinas ◽  
Tansu Gokce ◽  
Kate Bourne ◽  
Tony Horseman ◽  
...  

This paper presents the design, development and evaluation of a unique non-contact instrumentation system that can accurately measure the interface displacement between two rigid components in six degrees of freedom. The system was developed to allow measurement of the relative displacements between interfaces within a stacked column of brick-like components, with an accuracy of 0.05 mm and 0.1 degrees. The columns comprised up to 14 components, with each component being a scale model of a graphite brick within an Advanced Gas-cooled Reactor core. A set of 585 of these columns makes up the Multi Layer Array, which was designed to investigate the response of the reactor core to seismic inputs, with excitation levels up to 1 g from 0 to 100 Hz. The nature of the application required a compact and robust design capable of accurately recording fully coupled motion in all six degrees of freedom during dynamic testing. The novel design implemented 12 Hall effect sensors with a calibration procedure based on system identification techniques. The measurement uncertainty was ±0.050 mm for displacement and ±0.052 degrees for rotation, and the system can tolerate loss of data from two sensors with the uncertainly increasing to only 0.061 mm in translation and 0.088 degrees in rotation. The system has been deployed in a research programme that has enabled EDF to present seismic safety cases to the Office for Nuclear Regulation, resulting in life extension approvals for several reactors. The measurement system developed could be readily applied to other situations where the imposed level of stress at the interface causes negligible material strain, and accurate non-contact six-degree-of-freedom interface measurement is required.


Sensors ◽  
2020 ◽  
Vol 21 (1) ◽  
pp. 137
Author(s):  
Larisa Dunai ◽  
Martin Novak ◽  
Carmen García Espert

The present paper describes the development of a prosthetic hand based on human hand anatomy. The hand phalanges are printed with 3D printing with Polylactic Acid material. One of the main contributions is the investigation on the prosthetic hand joins; the proposed design enables one to create personalized joins that provide the prosthetic hand a high level of movement by increasing the degrees of freedom of the fingers. Moreover, the driven wire tendons show a progressive grasping movement, being the friction of the tendons with the phalanges very low. Another important point is the use of force sensitive resistors (FSR) for simulating the hand touch pressure. These are used for the grasping stop simulating touch pressure of the fingers. Surface Electromyogram (EMG) sensors allow the user to control the prosthetic hand-grasping start. Their use may provide the prosthetic hand the possibility of the classification of the hand movements. The practical results included in the paper prove the importance of the soft joins for the object manipulation and to get adapted to the object surface. Finally, the force sensitive sensors allow the prosthesis to actuate more naturally by adding conditions and classifications to the Electromyogram sensor.


2021 ◽  
Vol 11 (10) ◽  
pp. 4464
Author(s):  
Viritpon Srimaneepong ◽  
Artak Heboyan ◽  
Azeem Ul Yaqin Syed ◽  
Hai Anh Trinh ◽  
Pokpong Amornvit ◽  
...  

The loss of one or multiple fingers can lead to psychological problems as well as functional impairment. Various options exist for replacement and restoration after hand or finger loss. Prosthetic hand or finger prostheses improve esthetic outcomes and the quality of life for patients. Myoelectrically controlled hand prostheses have been used to attempt to produce different movements. The available articles (original research articles and review articles) on myoelectrically controlled finger/hand prostheses from January 1922 to February 2021 in English were reviewed using MEDLINE/PubMed, Web of Science, and ScienceDirect resources. The articles were searched using the keywords “finger/hand loss”, “finger prosthesis”, “myoelectric control”, and “prostheses” and relevant articles were selected. Myoelectric or electromyography (EMG) signals are read by myoelectrodes and the signals are amplified, from which the muscle’s naturally generated electricity can be measured. The control of the myoelectric (prosthetic) hands or fingers is important for artificial hand or finger movement; however, the precise control of prosthetic hands or fingers remains a problem. Rehabilitation after multiple finger loss is challenging. Implants in finger prostheses after multiple finger loss offer better finger prosthesis retention. This article presents an overview of myoelectric control regarding finger prosthesis for patients with finger implants following multiple finger loss.


Three basic models of the intracrystalline sorbed state are discussed: a localized phase, a mobile phase possessing two translational degrees of freedom, and a mobile phase with one translational degree of freedom. The isotherm and entropy of each of these models have been investigated for the ideal phase, and where possible the influence of sorbate-sorbate interactions has been considered. Expressions for the molal and differential entropies of each model are given as a function of sorbate concentration. The method of comparing theoretical isotherms and entropies with experimental observations is outlined.


2014 ◽  
Vol 926-930 ◽  
pp. 2054-2057
Author(s):  
Jun Hui He

This paper proposed customers to participate typology based on three dimensions, which are the customers’ autonomy in the process, the nature of the firm‐customer collaboration, and the stage of the innovation process. Then proposed customers to participate in the type of open innovation framework. Through the static comparative and dynamic evolution simulation found: customers tend to be open to participate in the development of new products pre innovation, the tendency to begin to choose the low participation of degrees of freedom, and ultimately tend to opt for a high degree of freedom to participate.


Sign in / Sign up

Export Citation Format

Share Document