scholarly journals Evaluation and enhancement of a low-cost NDIR CO<sub>2</sub> sensor

2017 ◽  
Author(s):  
Cory R. Martin ◽  
Ning Zeng ◽  
Anna Karion ◽  
Russell R. Dickerson ◽  
Xinrong Ren ◽  
...  

Abstract. Non-dispersive infrared (NDIR) sensors are a low-cost way to observe carbon dioxide concentrations in air, but their specified accuracy and precision are not sufficient for some scientific applications. An initial evaluation of six SenseAir K30 carbon dioxide NDIR sensors in a lab setting showed that without any calibration or correction, the sensors have an individual root mean square (RMS) error between ~ 5 to 21 parts per million (ppm) compared to a research-grade greenhouse gas analyzer using cavity enhanced laser absorption spectroscopy. Through further evaluation, after correcting for environmental variables with coefficients determined through a multivariate linear regression analysis, the calculated difference between the each of six individual K30 NDIR sensors and the higher-precision instrument had for one minute data a standard deviation of between 1.6 ppm and 4.4 ppm. The median standard deviation improved from 8.08 for off the shelf sensors to 1.89 ppm after correction and calibration, demonstrating the potential to provide useful information for ambient air monitoring.

2017 ◽  
Vol 10 (7) ◽  
pp. 2383-2395 ◽  
Author(s):  
Cory R. Martin ◽  
Ning Zeng ◽  
Anna Karion ◽  
Russell R. Dickerson ◽  
Xinrong Ren ◽  
...  

Abstract. Non-dispersive infrared (NDIR) sensors are a low-cost way to observe carbon dioxide concentrations in air, but their specified accuracy and precision are not sufficient for some scientific applications. An initial evaluation of six SenseAir K30 carbon dioxide NDIR sensors in a lab setting showed that without any calibration or correction, the sensors have an individual root mean square error (RMSE) between  ∼ 5 and 21 parts per million (ppm) compared to a research-grade greenhouse gas analyzer using cavity enhanced laser absorption spectroscopy. Through further evaluation, after correcting for environmental variables with coefficients determined through a multivariate linear regression analysis, the calculated difference between the each of six individual K30 NDIR sensors and the higher-precision instrument had an RMSE of between 1.7 and 4.3 ppm for 1 min data. The median RMSE improved from 9.6 for off-the-shelf sensors to 1.9 ppm after correction and calibration, demonstrating the potential to provide useful information for ambient air monitoring.


2001 ◽  
Vol 126 (6) ◽  
pp. 757-763 ◽  
Author(s):  
Fahrurrozi Aziz ◽  
Katrine A. Stewart ◽  
Sylvie Jenni

Temperature modification is the most investigated environmental factor considered to affect muskmelon (Cucumis melo L. Reticulatus Group) growth in a mulched minitunnel production system. Until now, effects on CO2 concentrations within the tunnel have been ignored. Experiments on production of `Earligold' netted muskmelon were conducted in 1997, 1998, and 1999 to determine daily CO2 concentrations for 10 mulched minitunnel and thermal water tube combinations. Carbon dioxide concentrations under nonperforated (clear or infrared-blocking polyethylene) tunnels were significantly higher (three to four times) than that of ambient air. Soil respiration under the plastic mulch was primarily responsible for increased CO2 levels in the tunnel. Daily CO2 concentrations in the tunnels varied little during early muskmelon growth, but fluctuated widely as the plants developed. Ventilation significantly decreased CO2 concentrations in the tunnels but levels remained significantly above the control and perforated tunnel treatments. When using mulched minitunnels for muskmelon production, daily CO2 concentrations should be recognized as a significant factor influencing growth.


Sensors ◽  
2020 ◽  
Vol 20 (23) ◽  
pp. 6714
Author(s):  
Rebecca A. Sugrue ◽  
Chelsea V. Preble ◽  
Thomas W. Kirchstetter

The exhaust plume capture method is a commonly used approach to measure pollutants emitted by in-use heavy-duty diesel trucks. Lower cost sensors, if used in place of traditional research-grade analyzers, could enable wider application of this method, including use as a monitoring tool to identify high-emitting trucks that may warrant inspection and maintenance. However, low-cost sensors have for the most part only been evaluated under ambient conditions as opposed to source-influenced environments with rapidly changing pollutant concentrations. This study compared black carbon (BC) emission factors determined using different BC and carbon dioxide (CO2) sensors that range in cost from $200 to $20,000. Controlled laboratory experiments show that traditional zero and span steady-state calibration checks are not robust indicators of sensor performance when sampling short duration concentration peaks. Fleet BC emission factor distributions measured at two locations at the Port of Oakland in California with 16 BC/CO2 sensor pairs were similar, but unique sensor pairs identified different high-emitting trucks. At one location, the low-cost PP Systems SBA-5 agreed on the classification of 90% of the high emitters identified by the LI-COR LI-7000 when both were paired with the Magee Scientific AE33. Conversely, lower cost BC sensors when paired with the LI-7000 misclassified more than 50% of high emitters when compared to the AE33/LI-7000. Confidence in emission factor quantification and high-emitter identification improves with larger integrated peak areas of CO2 and especially BC. This work highlights that sensor evaluation should be conducted under application-specific conditions, whether that be for ambient air monitoring or source characterization.


2019 ◽  
Vol 216 ◽  
pp. 116946 ◽  
Author(s):  
Brandon Feenstra ◽  
Vasileios Papapostolou ◽  
Sina Hasheminassab ◽  
Hang Zhang ◽  
Berj Der Boghossian ◽  
...  

Sensors ◽  
2017 ◽  
Vol 17 (7) ◽  
pp. 1520 ◽  
Author(s):  
Laurent Spinelle ◽  
Michel Gerboles ◽  
Gertjan Kok ◽  
Stefan Persijn ◽  
Tilman Sauerwald

Author(s):  
Derek E. Lambe ◽  
Kyle Seleski ◽  
Ranganathan Kumar ◽  
Saptarshi Basu

A novel method has been implemented for measuring the concentration of various gas species (water vapor, carbon dioxide) within fuel cell gas channels and other minichannel applications in a non-invasive manner through the use of tunable diode laser absorption spectroscopy (TDLAS). An optically accessible test cell has been designed to allow for the passage of 1–0.5 millimeter diameter laser beams along 12 mm-12 cm long flow paths, while also allowing for visual observation of the channels in order to detect the formation of liquid water. Concentrations of water vapor and carbon dioxide have been measured in situ within the test cell with a temporal resolution of 0.5 secs and 2.5 secs respectively. The technique is portable to high aspect ratio channels yielding concentration measurements of species over 1 mm long passages with an experimental uncertainty of 5%.


2020 ◽  
Author(s):  
Raja Singh

Dilution Ventilation is an accepted way of providing Natural Ventilation for reduction of Disease spread in Indoor Spaces. It is most relevant in low resource settings where the cost of advanced technologies may be a barrier. Studies have been performed in India to find a correlation between Ventilation of spaces and its role in the prevention of Tuberculosis, which is a major airborne disease with high incidence levels in India. These studies lack the measurement of the air changes in the room which is an important criterion to find out the disease spread by transmission models. This paper presents a new apparatus prepared to measure Air changes in an indoor space using Carbon Dioxide as a biomarker which acts as a surrogate for the ventilation in the space. The apparatus prepared uses a pre-existing carbon dioxide meter but adds value to it by creating a tamper-proof, vandal-resistant and a poke-resistant system. It also includes a built-in air suction and withdrawal system so that the sensor can be supplied with the ambient air in the room so that it can accurately give the carbon dioxide measurements. The study enhances the methods of investigation for Indoor Air Quality studies.