scholarly journals Evaluating the Effect of Artemisia Aerial Parts Extracts on Candida albicans growth and Shear Bond Strength of Soft Denture Liner

2021 ◽  
Vol 3 (2) ◽  
pp. 86-95
Author(s):  
Ayaat Nasser Abdul Nour ◽  
Amal Abdul Latif Rashid

After a period of use in the oral cavity the bond between denture base and soft denture liner weaken or fails creating a suitable environment for fungal colonization. Traditional medical plants that have antifungal agents are considered more safe and with few side effects. The objective of this study was to evaluate the effect of oil and ethanol extracts of Artemisia aerial parts on Candida albicans growth and shear bond strength of soft denture liner. Candida albicans species were isolated and diagnosed, oil and ethanol extracts of Artemisia were prepared, the effect of the extracts on Candida albicans were tested by agar well diffusion test and micro dilution test. Finally, 30 specimens of soft denture liner were prepared for testing shear bond strength by Universal Instron machine before and after incorporation of the extracts. The results showed that all the concentrations of oil extract inhibit the growth of Candida albicans except (12.5 mg/ml) and there were significant differences (P≤0.05) between all concentrations compared with Nystatin except between (100 and Nystatin) mg/ml in which there were no significant difference.  In ethanol extract only the concentrations (100 and 75) mg/ml inhibited the growth of Candida albicans and there were significant differences between all concentrations (P≤0.05) with Nystatin, while shear bond strength was increased in ethanol extract and there were significant differences with the control (P≤0.05), but it was not affected in oil extract and there were no significant differences with the control (P>0.05). Interestingly, it’s concluded that oil and ethanol extracts of Artemisia aerials parts had an effect on Candida albicans, while shear bond strength was not affected by oil extract but increased in ethanol extract.

2017 ◽  
Vol 05 (02) ◽  
pp. 084-089
Author(s):  
Alisha Dhingra ◽  
Ashu Gupta ◽  
Anshu Minocha ◽  
Nayantara Sen

Abstract Aim: The aim of this study was to compare the reversal of shear bond strength of composite to bleached enamel immediately after bleaching followed by application of various antioxidant solutions. Material and Methods: Seventy central incisors were divided into seven groups. Groups I and II served as unbleached and bleached controls respectively. Groups III, IV, V, VI and VII served as the experimental groups and were subjected to 37.5% hydrogen peroxide bleaching followed by 10 min application of 10% sodium ascorbate, 25% alpha-tocopherol, 6.5% grape seed extract, 5% lycopene and 5% green tea extract respectively. Following composite bonding, shear bond strength was determined and the results were analyzed using ANOVA followed by Post Hoc Multiple Comparisons test. Results: The bond strength values for Group I (positive control) were maximum and significantly different than all the other groups except Grape seed extract group (Group V). When compared to Group II (bleached control), all the groups showed significantly higher bond strength. Significant difference in the bond strength values were seen between Group III (10% sodium ascorbate) and Group V. Also values for Group V were significantly different from Group VI (5% lycopene). All the other values showed insignificantly different results. Conclusion: All the antioxidant solutions improved the shear bond strength values after bleaching but only Grape seed extract application reversed the values to the non bleached levels. Lycopene was least effective. Other antioxidants showed comparable results.


Materials ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3550
Author(s):  
Aerin Choi ◽  
Kyung-Hyeon Yoo ◽  
Seog-Young Yoon ◽  
Bong-Soo Park ◽  
In-Ryoung Kim ◽  
...  

Self-adhesive resins (SARs) contain adhesives, which simplify the procedures of resin application, and primers, which provide sufficient bonding ability. In this study, mesoporous bioactive glass nanoparticles (MBN) were added to a SAR to easily improve the physical properties and remineralization ability. The experimental resins comprised 1%, 3%, and 5% MBN mixed in Ortho Connect Flow (GC Corp, Tokyo, Japan). As the MBN content in the SAR increased, the microhardness increased, and a statistically significant difference was observed between the cases of 1% and 5% MBN addition. Shear bond strength increased for 1% and 3% MBN samples and decreased for 5% MBN. The addition of MBN indicated a statistically significant antibacterial effect on both gram-negative and gram-positive bacteria. The anti-demineralization experiment showed that the remineralization length increased with the MBN content of the sample. Through the above results, we found that SAR containing MBN has antibacterial and remineralization effects. Thus, by adding MBN to the SAR, we investigated the possibility of orthodontic resin development, wherein the strength is enhanced and the drawbacks of the conventional SAR addressed.


2014 ◽  
Vol 08 (04) ◽  
pp. 498-503 ◽  
Author(s):  
Lucas da Fonseca Roberti Garcia ◽  
Hebert Luis Rossetto ◽  
Fernanda de Carvalho Panzeri Pires-de-Souza

ABSTRACT Objective: To evaluate the shear bond strength of a novel calcium aluminate-based cement, EndoBinder (EB), to dentine in comparison with Grey and White Mineral Trioxide Aggregate (MTA). Materials and Methods: Root canal hemi-sections obtained from 30 extracted molar teeth were embedded in self-polymerized acrylic resin and were grounded wet in order to obtain a flat dentine surface. Next, the roots were randomly assigned into three groups (n = 10), according to the cement used, as follows: EB: EndoBinder; WMTA: White MTA and GMTA: Grey MTA. The shear bond strength test was performed using a Universal Testing Machine (0.5 mm/min) and the data were submitted to statistical analysis (1-way ANOVA and Tukey tests, P < 0.05). Results: EB presented the highest shear bond strength values; however, there was no statistically significant difference in comparison with GMTA (P > 0.05). WMTA presented the lowest mean values, which were significant in comparison with EB (P < 0.05). Conclusions: The novel calcium aluminate-based cement presented higher shear bond strength than WMTA, and should be considered as a promising alternative in endodontic therapy.


2004 ◽  
Vol 12 (3) ◽  
pp. 200-204 ◽  
Author(s):  
Gisele Maria Correr ◽  
Angela S. Caldo-Teixeira ◽  
Roberta Caroline Bruschi Alonso ◽  
Regina Maria Puppin-Rontani ◽  
Mário Alexandre Coelho Sinhoreti ◽  
...  

The aim of this study was to evaluate the effect of saliva contamination (SCT) and re-etching time (RET) on the shear bond strength (SBS) of the Fluroshield sealant. Forty-five extracted third molars were sectioned and flattened until reach an enamel surface area. Then, all samples were etched for 30 sec with 35% phosphoric acid and then they were distributed into 9 groups (n=10) according to SCT and RET (seconds), respectively: G1- control (no SCT and no RET); G2- 30s and 0s; G3- 60s and 0s; G4-30s and 2s; G5- 30s and 5s; G6- 30s and 15s; G7-60s and 2s; G8- 60s and 5s; G9- 60s and 15s. The sealant was applied according to the manufacturer's instructions. The samples were stored in distilled water at 37ºC for 72h and subjected to the SBS test. The results indicated that there was no statistically significant difference between the groups (p>0.05). However, it could be noticed that: 1- the longer the SCT, the lower the SBS values; 2 - the longer the RET, the higher the SBS values. It could be concluded that there was a tendency to the shortest SCT (30s) associated to the longest RET (5 and 15s) to reach similar SBS values for the control group.


2013 ◽  
Vol 1 (2) ◽  
pp. 175
Author(s):  
Bernardo Urbanetto Peres ◽  
Felipe Weidenbach Degrazzia ◽  
Renésio Armindo Ghers ◽  
Fabíola Rossato Arrais ◽  
Vilmar Antonio Ferrazzo

PURPOSE: To evaluate the shear bond strength (SBS) of metallic brackets bonded with Transbond Plus Self-Etching Primer (TPSEP) and Transbond Plus Color Change (TPCC) under contamination with a mixture of saliva and blood. MATERIALS AND METHODS: 42 human premolars were randomly divided into 2 groups (n=21). Group 1 (G1) were bonded under no contamination, and Group 2 (G2) was contaminated with saliva/blood before bonding. Both groups were bonded according to the manufacturer’s instructions and were cleaned with pumice before bonding. The shear bond strength (SBS) tests were performed after 24 hours in distilled water at 37°C and after thermocycling. RESULTS: Both groups showed a homogeneous distribution in the Levene’s test (p>0.05). The main shear bond strength value of G1 was 8.89 MPa with a standard deviation of 2.27; the value for G2 was 6.00 MPa with a standard deviation of 2.62 MPa. There was a significant difference between G1 and G2 (t-student test p<0.05). IRA scores indicated that the main value was IRA 0, and no significant difference (α=0.05) was found between the groups. CONCLUSION: Contamination of blood mixed with saliva significantly decreases the shear bond strength, but even so, the performance is clinically acceptable.


2014 ◽  
Vol 15 (6) ◽  
pp. 688-692 ◽  
Author(s):  
Sukumaran Anil ◽  
Farouk Ahmed Hussein ◽  
Mohammed Ibrahim Hashem ◽  
Elna P Chalisserry

ABSTRACT Objective The purpose of the current in-vivo study was to assess the effect of using 0.12% chlorhexidine (CHX) mouth rinse, before bonding, on shear bond strength of polycarbonate brackets bonded with composite adhesive. Subjects and methods Eighteen orthodontic patients with a mean age 21.41 ± 1.2 years, who were scheduled to have 2 or more first premolars extracted, were included in this study. Patients were referred for an oral prophylaxis program which included, in part, the use of a mouth rinse. Patients were divided into 2 groups, a test group of 9 patients who used 0.12% CHX gluconate mouth rinse twice daily and a control group of 9 patients who used a mouth rinse without CHX, but with same color. After 1 week, polycarbonate brackets were bonded to first premolars with Transbond XT composite adhesive. Premolars were extracted after 28 days and tested for shear bond strength on a universal testing machine. Student's t-test was used to compare shear bond strengths of both groups. Results No statistically significant difference was found in bond strengths’ values between both groups. The test group (with CHX) has mean shear bond strength of 14.21 ± 2.42 MPa whereas the control group (without CHX) revealed a mean strength of 14.52 ± 2.31 MPa. Conclusion The use of 0.12% CHX mouth rinse, for one week before bonding, did not affect the shear bond strength of polycarbonate brackets bonded with Transbond composite. Furthermore, these brackets showed clinically acceptable bond strength. How to cite this article Hussein FA, Hashem MI, Chalisserry EP, Anil S. The Impact of Chlorhexidine Mouth Rinse on the Bond Strength of Polycarbonate Orthodontic Brackets. J Contemp Dent Pract 2014;15(6):688-692.


2016 ◽  
Vol 17 (12) ◽  
pp. 997-1002 ◽  
Author(s):  
Fahad I Alkhudhairy ◽  
Zeeshan H Ahmad

ABSTRACT Introduction Various bulk-fill materials depending on their composition, viscosity, and flow ability have different physical and mechanical properties. The aim of this in vitro study was to determine and compare the shear bond strength and microleakage properties of activa restorative with other bulk-fill restorative materials surefil (SDR), Biodentine, ever X posterior. Materials and methods Forty permanent premolars were selected for shear bond strength, and 20 permanent premolars were selected with class II cavities on mesial and distal side for microleakage. Universal testing device was used to assess the shear bond strength. Microleakage was checked using dye penetration method under a stereomicroscope. Mean and standard deviation values were calculated from the recorded values. Intergroup comparison was done by one-way analysis of variance (ANOVA) followed by pairwise comparison using Tukey honestly significant difference (HSD) post hoc test. Results The mean shear bond strength was highest for SDR surefil followed by Ever X posterior, Bioactive restorative, and Biodentine respectively. In this study, SDR (surefil) showed better shear bond strength and better microleakage properties compared with the other test materials (F = 186.7157, p < 0.05). Conclusion The result of this study showed that flowable and fiber-reinforced composites have better shear bond strength and microleakage properties. Clinical significance Flowable bulk-fill composite resins can be used as dentin substitutes because of its superior properties. How to cite this article Alkhudhairy FI, Ahmad ZH. Comparison of Shear Bond Strength and Microleakage of Various Bulk-fill Bioactive Dentin substitutes: An in vitro study. J Contemp Dent Pract 2016;17(12):997-1002.


Author(s):  
Nasrin Farhadian ◽  
Amirfarhang Miresmaeili ◽  
Vahid Shahidi Zandi

Objectives: The purpose of this randomized clinical trial (RCT) was to compare the shear bond strength (SBS) of orthodontic brackets bonded to enamel with conventional acid-etch (AE) technique and self-etching primers (SEP). Materials and Methods: Twenty-two patients, requiring extraction of two bicuspids for orthodontic reasons, were recruited. In each individual, following blinding and allocation concealment, one intact premolar received conventional AE, whereas the contralateral premolar received SEP with a split-mouth design. Bonded brackets remained in the oral cavity for two months. Afterward, the teeth were extracted without debonding the brackets. SBS and adhesive remnant index (ARI) were measured using a Universal Instron machine and a stereomicroscope, respectively. Results: The mean SBS of the conventional AE and SEP groups was 9.53 and 9.20 MPa, respectively. Paired t-test showed no statistically significant difference between the two groups (P=0.096). Comparison of ARI between the two groups, using Wilcoxon test, indicated that significantly less adhesive remained on enamel with brackets bonded with SEP compared to brackets bonded with conventional AE (P<0.001) although the SBS was higher in the AE group. Conclusion: The present study indicated that although there is no significant difference in SBS between SEP and conventional AE for bonding orthodontic metal brackets, the amount of residual adhesive on the enamel surface is significantly less with SEP than with conventional AE. (IRCT registration number: IRCT201705099086N3).


2020 ◽  
Vol 25 (1) ◽  
pp. 28-35
Author(s):  
Fernando César Moreira ◽  
Helder Baldi Jacob ◽  
Luis Geraldo Vaz ◽  
Antonio Carlos Guastaldi

ABSTRACT Objective: The purpose of this study was to evaluate the effect of the Yd:YAG laser irradiation on orthodontic bracket base surface. Shear bond strength (SBS) values and sites of the bonding failure interfaces were quantified. Methods: Brackets were divided into two groups: OP (One Piece - integral sandblast base) and OPL (One Piece - laser irradiation). The brackets were randomly bonded on an intact enamel surface of 40 bovine incisors. The SBS tests were carry out using a universal test machine. A stereomicroscopy was used to evaluate the adhesive remnant index (ARI), and surface characterization was performed by scanning electron microscopy (SEM). Student’s t-test was used to compare the SBS between the two groups (p< 0.05). Frequencies and chi-square analysis were applied to evaluate the ARI scores. Results: OPL group showed higher value (p< 0.001) of SBS than OP group (43.95 MPa and 34.81 MPa, respectively). ARI showed significant difference (p< 0.001) between OPL group (ARI 0 = 100%) and OP group (ARI 0 = 15%). SEM showed a higher affinity between the adhesive and the irradiated laser base surface. Conclusions: Yd:YAG laser irradiation on bracket base increased SBS values, showing that bonding failure occurs at the enamel/adhesive interface. Laser-etched bracket base may be used instead of conventional bases in cases where higher adhesion is required, reducing bracket-bonding failure.


2013 ◽  
Vol 24 (3) ◽  
pp. 279-283 ◽  
Author(s):  
Ana Caroline Silva Gama ◽  
Andre Guaraci de Vito Moraes ◽  
Lilyan Cardoso Yamasaki ◽  
Alessandro Dourado Loguercio ◽  
Ceci Nunes Carvalho ◽  
...  

The purpose of this study was to evaluate in vitro the shear bond strength to enamel, flexural strength, flexural modulus, and contraction stress of one orthodontic composite and two flowable composites. Orthodontic brackets were bonded to 45 human maxillary premolars with the composites Transbond XT, Filtek Z-350 flow and Opallis flow and tested for shear bond strength. For measurement of flexural strength and flexural modulus, specimens were fabricated and tested under flexion. For the contraction stress test, cylindrical specimens were tested and an extensometer determined the height of the specimens. The data were subjected to one-way ANOVA and Tukey's test (α=0.05). The shear bond strength values were significantly lower (p<0.05) for the flowable composites compared with the orthodontic composite. For the flexural strength, no statistically significant difference was found among the composites (p>0.05) while the flexural modulus was significantly higher (p<0.05) for Transbond XT than for Filtek Z-350 flow and Opallis flow. The orthodontic composite presented significantly lower contraction stress values than the flowable composites (p<0.05). The light-activated orthodontic composite material presented higher flexural modulus and shear bond strength and lower contraction stress than both flowable composites.