scholarly journals THE EFFECTS OF GAP SPACING RATIO ON FLOW STRUCTURE AND HEAT TRANSFER CHARACTERISTIC FOR THE V-ORIFICE IN THE SQUARE CHANNEL HEAT EXCHANGER

2019 ◽  
Vol 12 ◽  
Author(s):  
Withada Jedsadaratanachai ◽  
Amnart Boonloi
Author(s):  
Handry Afrianto ◽  
Md. Riyad Tanshen ◽  
B. Munkhbayar ◽  
U. Tony Suryo ◽  
Hanshik Chung ◽  
...  

2006 ◽  
Vol 129 (9) ◽  
pp. 1256-1267 ◽  
Author(s):  
Worachest Pirompugd ◽  
Chi-Chuan Wang ◽  
Somchai Wongwises

This study proposes a new method, namely the “fully wet and fully dry tiny circular fin method,” for analyzing the heat and mass transfer characteristics of plain fin-and-tube heat exchangers under dehumidifying conditions. The present method is developed from the tube-by-tube method proposed in the previous study by the same authors. The analysis of the fin-and-tube heat exchangers is carried out by dividing the heat exchanger into many tiny segments. A tiny segment will be assumed with fully wet or fully dry conditions. This method is capable of handling the plain fin-and-tube heat exchanger under fully wet and partially wet conditions. The heat and mass transfer characteristics are presented in dimensionless terms. The ratio of the heat transfer characteristic to mass transfer characteristic is also studied. Based on the reduced results, it is found that the heat transfer and mass transfer characteristics are insensitive to changes in fin spacing. The influence of the inlet relative humidity on the heat transfer characteristic is rather small. For one and two row configurations, a considerable increase of the mass transfer characteristic is encountered when partially wet conditions take place. The heat transfer characteristic is about the same in fully wet and partially wet conditions provided that the number of tube rows is equal to or greater than four. Correlations are proposed to describe the heat and mass characteristics for the present plain fin configuration.


2014 ◽  
Vol 6 ◽  
pp. 637052 ◽  
Author(s):  
Xuehong Wu ◽  
Lihua Feng ◽  
Dandan Liu ◽  
Hao Meng ◽  
Yanli Lu

The dimpled fin has excellent heat transfer performance and has attracted a lot of attention to apply on the fin and tube heat exchanger. A study presents to investigate the effects of number of tube rows on the air-side heat transfer characteristics of dimpled fin for velocity ranging from 1 to 3 m/s. The Q/Δ P and Q/((Δ P × V)) are used to evaluate the heat transfer performance of the heat exchanger. The results show that the dimpled arrangement can change the mainstream direction, increase the disturbance, and enhance the heat transfer. With the increase of the number of tube rows, the average Nusselt number decreases and Q/Δ P and Q/((Δ P × V)) increase gradually. Compared with the multipipe tube rows, the performance of two-row tube is better.


Sign in / Sign up

Export Citation Format

Share Document