scholarly journals Experimental analysis of solar thermal integrated MD system for cogeneration of drinking water and hot water for single family villa in Dubai using flat plate and evacuated tube solar collectors

2017 ◽  
Vol 92 ◽  
pp. 46-59 ◽  
Author(s):  
Muhammad Asim ◽  
Muhammad Imran ◽  
Michael K.H. Leung ◽  
N.T. Uday Kumar ◽  
Andrew R. Martin ◽  
...  
2018 ◽  
Vol 4 (3) ◽  
pp. 25 ◽  
Author(s):  
Daniel Ferrández ◽  
Carlos Moron ◽  
Jorge Pablo Díaz ◽  
Pablo Saiz

ResumenEl actual Código Técnico de la Edificación (CTE) pone de manifiesto la necesidad de cubrir parte de la demanda energética requerida para el abastecimiento de agua caliente sanitaria y climatización de piscinas cubiertas mediante sistemas de aprovechamiento de la energía solar térmica. En este artículo se presenta una comparativa entre las dos principales tipologías de captadores solares térmicos que existen en el mercado: el captador de placa plana y el captador de tubo de vacío, atendiendo a criterios de fracción solar, diseño e integración arquitectónica. Todo ello a fin de discernir en qué circunstancias es más favorable el uso de uno u otro sistema, comparando los resultados obtenidos mediante programas de simulación con la toma de medidas in situ.AbstractThe current Technical Building Code (CTE) highlights the need to cover part of the energy demand required for the supply of hot water and heating of indoor swimming pools using solar thermal systems. This article presents a comparison between the two main types of solar thermal collectors that exist in the market: the flat plate solar collector and the vacuum tube solar collector, according to criteria of solar fraction, design and architectural integration. All of this in order to discern in what circumstances the use of one or the other system is more favourable, comparing the results obtained through simulation programs with the taking of measurements in situ.


2021 ◽  
Author(s):  
Kamyar Tanha

This thesis is focused on the performance of the two SDHW systems of the sustainable Archetype houses in Vaughan, Ontario with daily hot water consumption of 225 litres. The first system consists of a flat plate solar thermal collector in conjunction with a gas boiler and a DWHR. The second SDHW system consists of an evacuated tube collector, an electric tank and a DWHR. The experimental results showed that the DWHRs were capable of an annual heat recovery of 789 kWh. The flat plate and evacuated tube collectors had an annual thermal energy output of 2038 kWh and 1383 kWh. The systems were also modeled in TRNSYS and validated with the experimental results. The simulated results showed that Edmonton has the highest annual energy consumption of 3763.4 kWh and 2852.9 kWh by gas boiler and electric tank and that the solar thermal collectors and DWHRs are most beneficial in Edmonton.


Author(s):  
Enrico Zambolin ◽  
Davide Del Col ◽  
Andrea Padovan

New comparative tests on different types of solar collectors are presented in this paper. Tests have been performed at the solar energy conversion laboratory of the University of Padova. Two standard glazed flat plate collectors and one evacuated tube collector are installed in parallel; the evacuated collector is a direct flow through type with external CPC (compound parabolic concentrator) reflectors. The present test rig allows to make measurements on the flat plate, on the evacuated collector or on both simultaneously, by simply acting on the valves to modify the circuit. In this paper measurements of the performance of the evacuated tube collector and flat plate collectors working at the same conditions are reported. Efficiency in stationary conditions is measured following the standard EN 12975-2 [1] and it is compared with the input/output curves measured for an entire day. The main purpose of the present work is to characterize and to compare the daily energy performance of the two types of collectors. An effective mean for describing and analyzing the daily performance is the so called input/output diagram, in which the collected solar energy is plotted against the daily incident solar radiation. Test runs have been performed in several conditions to reproduce different conventional uses (hot water, space heating, solar cooling).


2021 ◽  
Vol 13 (24) ◽  
pp. 13870
Author(s):  
Esteban Zalamea-Leon ◽  
Edgar A. Barragán-Escandón ◽  
John Calle-Sigüencia ◽  
Mateo Astudillo-Flores ◽  
Diego Juela-Quintuña

The performance of solar thermal technology under high-altitude equatorial climatic and solar path conditions has not been determined. Evacuated tube solar collectors are more efficient than flat plate collectors in cold and cloudy regions; however, due to their dependence on orientation, the irradiation incidence between the tubes of these collectors can be blocked. In this study, the performance of these types of collectors was analyzed to determine the implications of their orientation under these specific climate conditions. Four solar thermal systems were installed: two of the systems used evacuated tube collectors, and two used flat plate collectors. Each collector was connected to storage and discharge points to simulate residential consumption when observing the real performance of the four systems in terms of irradiation availability. The evacuated tube collectors were more efficient and reduced the backup energy requirement by up to 20.6% more on average than the flat plate collectors. In addition, the performance of the evacuated tube collectors increased by up to 9.8% when the tubes were arranged parallel to the solar path, compared to when they were arranged perpendicular to the solar path, verifying that the blockage effect is an important parameter to consider for evacuated tube technology. The main novelty of this research is the comparison of these two technologies under different orientations, with perpendicular and parallel dispositions toward the solar path, in a high-altitude equatorial location where solar collectors are not typically oriented in any particular orientation. To the best of our knowledge, this is the first complete analysis of real systems deployed under these conditions.


2021 ◽  
Author(s):  
Kamyar Tanha

This thesis is focused on the performance of the two SDHW systems of the sustainable Archetype houses in Vaughan, Ontario with daily hot water consumption of 225 litres. The first system consists of a flat plate solar thermal collector in conjunction with a gas boiler and a DWHR. The second SDHW system consists of an evacuated tube collector, an electric tank and a DWHR. The experimental results showed that the DWHRs were capable of an annual heat recovery of 789 kWh. The flat plate and evacuated tube collectors had an annual thermal energy output of 2038 kWh and 1383 kWh. The systems were also modeled in TRNSYS and validated with the experimental results. The simulated results showed that Edmonton has the highest annual energy consumption of 3763.4 kWh and 2852.9 kWh by gas boiler and electric tank and that the solar thermal collectors and DWHRs are most beneficial in Edmonton.


Author(s):  
Andy Walker ◽  
Fariborz Mahjouri ◽  
Robert Stiteler

This paper describes design, simulation, construction and measured initial performance of a solar water heating system (360 Evacuated Heat-Pipe Collector tubes, 54 m2 gross area, 36 m2 net absorber area) installed at the top of the hot water recirculation loop in the Social Security Mid-Atlantic Center in Philadelphia. Water returning to the hot water storage tank is heated by the solar array when solar energy is available. This new approach, as opposed to the more conventional approach of preheating incoming water, is made possible by the thermal diode effect of heat pipes and low heat loss from evacuated tube solar collectors. The simplicity of this approach and its low installation costs makes the deployment of solar energy in existing commercial buildings more attractive, especially where the roof is far removed from the water heating system, which is often in the basement. Initial observed performance of the system is reported. Hourly simulation estimates annual energy delivery of 111 GJ/year of solar heat and that the annual efficiency (based on the 54 m2 gross area) of the solar collectors is 41%, and that of the entire system including parasitic pump power, heat loss due to freeze protection, and heat loss from connecting piping is 34%. Annual average collector efficiency based on a net aperture area of 36 m2 is 61.5% according to the hourly simulation.


2016 ◽  
Vol 91 ◽  
pp. 477-485 ◽  
Author(s):  
Mario Nájera-Trejo ◽  
Ignacio R. Martin-Domínguez ◽  
Jorge A. Escobedo-Bretado

Sign in / Sign up

Export Citation Format

Share Document