scholarly journals Sanitary Status and Occurrence of Some Water-Borne Pathogens in Well and Surface Waters of Panhauya Community and Ahmadu Bello University Farm, Zaria

2020 ◽  
Vol 5 (2) ◽  
pp. 138-147
Author(s):  
S. L. Afegbua ◽  

The Sustainable Development Goal on sanitation aims to achieve universal access to good health, affordable drinking water, sanitation and an end to open defeacation by 2030. The recent ranking of Nigeria as first globally for open defecation is of public and environmental health concern. This study assessed the sanitary condition and the microbiological quality of well and surface waters of Panhauya community and Ahmadu Bello University farm, Zaria, and the antibiogram of the bacterial isolates.. Based on the WHO criteria, the sanitary inspection showed that 16.7%, 54.2%, 25% and 4.2% of the water sampling points had a very high, high, intermediate and low risk of contamination respectively. Occurrence of Escherichia coli, Giardia lamblia, Entamoeba histolytica, Pseudomonas aeruginosa, Salmonella spp and Vibrio cholerae in water samples from Panhuaya community was 87.5%, 75%, 68.8%, 50%, 25% and 12.5% respectively. In ABU farm Shika, the occurrence was; E. coli (75%), E. histolytica (63%), G. lamblia and Salmonella spp. All E. coli isolates exhibited high multidrug resistance to antibiotics screened with a MAR index of 0.3-0.8. The drinking water sources in Panhuaya and ABU farm were unsafe and the presence of these pathogens in the water samples may be attributed to a number of factors including poor sanitation, manure application and open defecation practice. This indicates a public health risk to the residents and emphasises the need for safe water supplies sanitation and antibiotic stewardship. Keywords: Well water; surface water; sanitary inspection; open defecation; water-borne pathogens; Zaria.

1999 ◽  
Vol 62 (11) ◽  
pp. 1278-1284 ◽  
Author(s):  
FRANCINA M. MOSUPYE ◽  
ALEXANDER von HOLY

Fifty-one ready-to-eat street foods, 18 dishwater, and 18 surface swab samples were collected from six vendors in Johannesburg, South Africa. Food temperatures were recorded at the time of sampling. Standard methods were used to determine aerobic plate counts (APCs), spore counts (SCs), and Enterobacteriaceae counts (ECs) for food samples as well as coliform counts (CCs) for water and swab samples. In addition, Petrifilm Escherichia coli count (PC) plates were used for the enumeration of coliforms in food, water, and swab samples. The presence of selected foodborne pathogens in the food samples as well as the presence of nonpathogenic E. coli 1 (in food and water samples) was also tested for. Predominant colonies isolated from APC plates were characterized to the genus level. Holding temperatures for cooked meats and gravies ranged from 42.0 to 94.0°C, and those for uncooked salads ranged from 29.0 to 39.0°C. Mean APC values of 3.4 (±0.4) log CFU/g, 4.0 (±1.2) log CFU/ml, and 2.1 (±0.4) log CFU/25 cm2 were obtained for food, water, and swab samples, respectively. Mean SC values of 1.6 (±0.2) log CFU/g and 1.5 (±0.3) log CFU/25 cm2 were obtained for food and swab samples, respectively. A mean EC value of 2.0 (±0.4) log CFU/g for food samples and mean CC values of 2.5 (±0.3) log CFU/ml and 1.3 (±0.3) log CFU/25 cm2 for water and swab samples, respectively, were determined. Mean PC values of 1.6 (±0.1) log CFU/g, 1.9 (±0.6) log CFU/ml, and 1.4 (±0.4) log CFU/25 cm2 were determined for food, water, and swab samples, respectively. Bacillus cereus was detected in 22%, Clostridium perfringens in 16%, Salmonella spp. in 2%, and E. coli (non-O157:H+) in 2% of the 51 food samples. E. coli was found in 14 water samples (78%) and in 3 food samples (6%). Campylobacter spp., Listeria monocytogenes, Staphylococcus aureus, Vibrio cholerae, and Yersinia enterocolitica were also tested for in the food samples, but they were not detected. The 340 isolates obtained from APC plates for food, water, and swab samples were predominantly Bacillus spp., Micrococcus spp., and Staphylococcus spp. for all three sample types. It was concluded that the foods analyzed in this study were of acceptable quality and safety.


2014 ◽  
Vol 13 (2) ◽  
pp. 340-352 ◽  
Author(s):  
Andrée F. Maheux ◽  
Vanessa Dion-Dupont ◽  
Sébastien Bouchard ◽  
Marc-Antoine Bisson ◽  
Michel G. Bergeron ◽  
...  

The MI agar, Colilert®, Chromocult coliform® agar, and DC with BCIG agar chromogenic culture-based methods used to assess microbiological quality of drinking water were compared in terms of their ubiquity, sensitivity, ease of use, growth of atypical colonies and affordability. For ubiquity, 129 total coliform (representing 76 species) and 19 Escherichia coli strains were tested. Then, 635 1-L well water samples were divided into 100 mL subsamples for testing by all four methods. Test results showed that 70.5, 52.7, 36.4, and 23.3% of the non-E. coli total coliform strains and 94.7, 94.7, 89.5, and 89.5% of the 19 E. coli strains yielded a positive signal with the four methods, respectively. They also yielded a total coliform positive signal for 66.5, 51.7, 64.9, and 55.0% and an E. coli positive signal for 16.1, 14.8, 17.3, and 13.4% of the 635 well water samples tested, respectively. Results showed that Colilert® is the most expensive method tested in terms of reactants, yet it is the easiest to use. Large numbers of atypical colonies were also often observed on Chromocult coliform® and DC with BCIG, thereby challenging the target microorganism count. Thus, the MI agar method seems to be the best option for the assessment of drinking water quality.


2008 ◽  
Vol 54 (6) ◽  
pp. 495-500 ◽  
Author(s):  
B. Lévesque ◽  
D. Pereg ◽  
E. Watkinson ◽  
J.S. Maguire ◽  
L. Bissonnette ◽  
...  

Bermuda residents collect rainwater from rooftops to fulfil their freshwater needs. The objective of this study was to assess the microbiological quality of drinking water in household tanks throughout Bermuda. The tanks surveyed were selected randomly from the electoral register. Governmental officers visited the selected household (n = 102) to collect water samples and administer a short questionnaire about the tank characteristics, the residents’ habits in terms of water use, and general information on the water collecting system and its maintenance. At the same time, water samples were collected for analysis and total coliforms and Escherichia coli were determined by 2 methods (membrane filtration and culture on chromogenic media, Colilert kit). Results from the 2 methods were highly correlated and showed that approximately 90% of the samples analysed were contaminated with total coliforms in concentrations exceeding 10 CFU/100 mL, and approximately 66% of samples showed contamination with E. coli. Tank cleaning in the year prior to sampling seems to protect against water contamination. If rainwater collection from roofs is the most efficient mean for providing freshwater to Bermudians, it must not be considered a source of high quality drinking water because of the high levels of microbial contamination.


2014 ◽  
Vol 13 (1) ◽  
pp. 67-72
Author(s):  
Andrée F. Maheux ◽  
Vanessa Dion-Dupont ◽  
Marc-Antoine Bisson ◽  
Sébastien Bouchard ◽  
Éric Jubinville ◽  
...  

MI agar and Colilert®, as well as mFC agar combined with an Escherichia coli-specific molecular assay (mFC + E. coli rtPCR), were compared in terms of their sensitivity, ease of use, time to result and affordability. The three methods yielded a positive E. coli signal for 11.5, 10.8, and 11.5% of the 968 well water samples tested, respectively. One hundred and thirty-six (136) samples gave blue colonies on mFC agar and required confirmation. E. coli-specific rtPCR showed false-positive results in 23.5% (32/136) of cases. In terms of ease of use, Colilert was the simplest method to use while the MI method provided ease of use comparable to all membrane filtration methods. However, the mFC + E. coli rtPCR assay required highly trained employees for confirmation purposes. In terms of affordability, and considering contamination rate of well water samples tested, the Colilert method and the mFC + E. coli rtPCR assay were at least five times more costly than the MI agar method. Overall, compared with the other two methods tested, the MI agar method offers the most advantages to assess drinking water quality.


Author(s):  
Udoh I.P., Iloghalu ◽  
Iloghalu, Ijenwa Amarachi ◽  
Aladenika S.T.

Infectious diseases control of recent is a major health concern globally due to high increase in number of microorganisms that are resistant to conventional antimicrobial agents. This study aimed at ascertaining the microbiological quality and multiple antibiotic resistance profile of E. coli strains isolated from different sources of drinking water. A total of 136 water samples from different drinking water sources, including the storage tanks (the school and the commercial storage tank), sachet and bottle water were obtained from University of Nigeria Enugu Campus and analyzed. Standard microbiological techniques were employed for bacteria isolation, identification and antibiogram. From the water samples collected 25 E. coli strains were isolated. The school storage tanks account for 60% of the isolates, while bottled water showed no growth. 92% of the E. coli isolated showed resistance to the tested antibiotics. Resistant were higher with Augmentin (64%), Chloramphenicol (48%) and Streptomycin 11 (44%) while most were sensitive to Tarivid and Perfloxacine (100%). Isolates from school storage water sources showed the highest resistance to Augmentin (76.5%) while those from commercial storage water sources showed the highest resistance to Streptomycin (66.7%). Out of the 23 (92%) antibiotics resistant E. coli isolates 18 (78.3%) were multidrug resistance (MDR). The school storage water sources had the highest number of MDR E. coli 14 (77.8%) followed by the commercial storage water sources 4 (22.2%), but the sachet and bottled water had no MDR E. coli. In conclusion, drinking water may potentially contribute to the source of multidrug resistance E. coli in this community


2017 ◽  
Vol 16 (2) ◽  
pp. 275-288 ◽  
Author(s):  
Muhammed A. Usman ◽  
Nicolas Gerber ◽  
Evita H. Pangaribowo

Abstract This study aims at assessing the determinants of microbiological contamination of household drinking water under multiple-use water systems in rural areas of Ethiopia. For this analysis, a random sample of 454 households was surveyed between February and March 2014, and water samples from community sources and household storage containers were collected and tested for fecal contamination. The number of Escherichia coli (E. coli) colony-forming units per 100 mL water was used as an indicator of fecal contamination. The microbiological tests demonstrated that 58% of household stored water samples and 38% of protected community water sources were contaminated with E. coli. Moreover, most improved water sources often considered to provide safe water showed the presence of E. coli. The result shows that households' stored water collected from unprotected wells/springs had higher levels of E. coli than stored water from alternative sources. Distance to water sources and water collection containers are also strongly associated with stored water quality. To ensure the quality of stored water, the study suggests that there is a need to promote water safety from the point-of-source to point-of-use, with due considerations for the linkages between water and agriculture to advance the Sustainable Development Goal 6 of ensuring access to clean water for everyone.


Coatings ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 1544
Author(s):  
Sadaf Tariq ◽  
Sobia Tabassum ◽  
Sadia Aslam ◽  
Mika Sillanpaa ◽  
Wahidah H. Al-Qahtani ◽  
...  

Diarrheagenic Escherichia coli (DEC) are associated with frequent incidences of waterborne infections and pose health risk to individuals who contact water for domestic or recreational uses. Detection of DEC pathotypes in drinking water can be used as an indicator of fecal contamination. This study aimed to investigate the occurrence of DEC pathotypes and their capacity to form biofilms in drinking water samples collected from different water sources. In this study, PCR analysis was used to determine the occurrence of four clinically significant virulence genes of diarrheagenic E. coli, eaeA (Enteropathogenic E. coli), stx1, stx2 (Enterohemorrhagic E. coli) and sth (Enterotoxigenic E. coli), in drinking water samples (n = 35) by using specific primers and conditions. PCR amplicons were visualized by using agarose gel electrophoresis. A total of 12/35 (34%) samples were detected as positive for at least one of the four DEC virulence genes and 11/12 (91%) E. coli isolates harbored virulence gene while 1/12 (8%) E. coli isolates harbored none. The eaeA and sth genes were the most detected genes (75%), while stx1 and stx2 genes were least detected genes (66%). Biofilm assay confirmed that ETEC pathotypes can cause damage in enteric walls by attaching and effacing to persist diarrheal conditions. This study indicated that drinking water of different sources is contaminated with potential DEC pathotypes and it can be a source of diarrheal diseases. The amplification of four virulence genes associated with DEC pathotypes (EPEC, EHEC and ETEC) in drinking water demonstrates that potentially virulent DEC pathotypes are distributed in water sources and may be a cause of health concern. There is, therefore, an urgent need to monitor DEC pathotypes in drinking water.


2021 ◽  
Vol 193 (8) ◽  
Author(s):  
Desmond Tichaona Mugadza ◽  
Sibusisiwe Isabel Nduku ◽  
Edlyn Gweme ◽  
Sherpherd Manhokwe ◽  
Patience Marume ◽  
...  

2017 ◽  
Vol 38 (1) ◽  
pp. 175 ◽  
Author(s):  
Natalia Harumi Niguma ◽  
Jacinta Sanchez Pelayo ◽  
Tereza Cristina Rocha Moreira de Oliveira

The aims of this study were to evaluate the contamination of lettuce (Lactuca sativa), produced in Londrina, Paraná (PR), with total coliform, coliform at 45 °C, E. coli, and Salmonella spp.; and to determine the E. coli contamination of irrigation water used at the farms studied. Four farms were evaluated, of which three produced lettuce using a conventional system and one using an organic system. An evaluation of the production practices of the farms was also carried out. A total of 111 samples were analyzed, 71 lettuce samples from the conventional system and 40 samples from the organic system. A total of eight irrigation water samples were collected for analysis. Coliform at 45 °C counts above the limit tolerated by Brazilian legislation were observed in 2.8% (2/71) of conventionally grown lettuce samples, and Salmonella spp. was isolated in 1.4% (1/71) of those samples. In the organic lettuce samples, 12.5% (5/40) had coliform at 45 °C counts above the limit tolerated and Salmonella spp. was not detected. Irrigation water samples from three farms were unsatisfactory, with counts higher than 102MPN of E. coli per 100mL. The results of this study demonstrate that most conventionally grown lettuce samples show good sanitary conditions in production, and that lettuce contamination is not related to contamination found in irrigation water samples. The results also showed that the organic production practices required by Brazilian certification agencies should be applied to ensure that contamination of produced lettuce remains controlled.


2007 ◽  
Vol 5 (S1) ◽  
pp. 67-79 ◽  
Author(s):  
J. Åström ◽  
T. J. R. Pettersson ◽  
T. A. Stenström

Microbial contamination of surface waters constitutes a health risk for drinking water consumers which may be lowered by closing the raw water intake. We have evaluated microbial discharge events reported in the river Göta älv, which is used for raw water supply to the city of Göteborg. Elevated levels of faecal indicator bacteria were observed during periods of closed raw water intake. High bacteria levels were, however, also occasionally detected during periods of open intake, probably as a result of microbial discharge far upstream in the river which may be difficult to predict and manage by closing the intake. Accumulated upstream precipitations, resulting in surface runoff and wastewater contaminations in the catchment, correlated positively with the levels of total coliforms, E. coli, intestinal enterococci and sulfite-reducing clostridia. Levels of faecal indicator organisms were negatively correlated to the water temperature due to enhanced survival at lower temperatures. Wastewater discharges from a municipality located just upstream of the water intake resulted in elevated E. coli concentrations downstream at the raw water intake for Göteborg. To improve the prediction of microbial contaminations within the river Göta älv, monitoring data on turbidity and upstream precipitation are of particular importance.


Sign in / Sign up

Export Citation Format

Share Document