scholarly journals Voltage Stability Improvement with finest position of UPFC using GA &PSO

Power system is a largely inter connected network, due to this interconnection some of the lines may get over loaded and voltage collapse will occur , hence these lines are called weak lines, this causes serious voltage instability at the particular lines of the power system. The improvement of stability will achieve by controlling the reactive power flow. The Flexible Alternating Current Transmission Systems (FACTS) devices have been proposed to effectively controlling the power flow in the lines and to regulate the bus voltages in electrical power systems, resulting in an increased power transfer capability, low system losses and improved stability. In FACTS devices the Unified Power Flow Controller (UPFC) is one of the most promising device for power flow control. It can either simultaneously or selectively control both real and reactive flow and bus voltage. UPFC is a combination of shunt and series compensating devices. Optimal location of UPFC is determined based on Voltage Stability Index (VSI). GA and PSO techniques are used to set the parameters of UPFC [6]. The objective function formulated here is fitness function, which has to be maximized for net saving. The results obtained using PSO on IEEE 14 Bus is compared with that of results obtained using GA, to show the validity of the proposed techniques and for comparison purposes

2012 ◽  
Vol 61 (2) ◽  
pp. 239-250 ◽  
Author(s):  
M. Kumar ◽  
P. Renuga

Application of UPFC for enhancement of voltage profile and minimization of losses using Fast Voltage Stability Index (FVSI)Transmission line loss minimization in a power system is an important research issue and it can be achieved by means of reactive power compensation. The unscheduled increment of load in a power system has driven the system to experience stressed conditions. This phenomenon has also led to voltage profile depreciation below the acceptable secure limit. The significance and use of Flexible AC Transmission System (FACTS) devices and capacitor placement is in order to alleviate the voltage profile decay problem. The optimal value of compensating devices requires proper optimization technique, able to search the optimal solution with less computational burden. This paper presents a technique to provide simultaneous or individual controls of basic system parameter like transmission voltage, impedance and phase angle, thereby controlling the transmitted power using Unified Power Flow Controller (UPFC) based on Bacterial Foraging (BF) algorithm. Voltage stability level of the system is defined on the Fast Voltage Stability Index (FVSI) of the lines. The IEEE 14-bus system is used as the test system to demonstrate the applicability and efficiency of the proposed system. The test result showed that the location of UPFC improves the voltage profile and also minimize the real power loss.


Now days’ electrical power requirement has enlarged expanding as expansion & restructuring of electrical power system (PS) for generation & transmission in power sector is critically limited due to current resources & environmental circumstances. As outcome, approximately of corridors of power transmission overhead lines are greatly loaded & congested. Also major issue of power system voltage stability becomes power transfer restricted and capability issue. A Modern power electronics technology FATCS considered device Static Synchronous Series Compensator (SSSC) is VSC demanded series FACTS equipment. Unified power flow controller (UPFC) is to manage power flow (PF), voltage magnitude & phase angle. In this research paper suggested to maintain voltage magnitude as well as PF of faulty lines. The consequence of mutation of PS parameters like voltage, phase angle, active power, reactive power, & overall power factor with & without SSSC & UPFC have also incorporated. Assessment of PS safety is essential in society to expand customs to sustain system functions when one or more components fail. A PS is "secure" when it can defy loss of one or more ingredients & still go on working without major problems. The Contingency event investigation technique is taken to identify electrical node PF in faulty transmission lines (TL). The Performance of PS has been tested on IEEE 14-Bus System.


Author(s):  
Mahmood Khalid Zarkani ◽  
Ahmed Sahib Tukkee ◽  
Mohammed Jasim Alali

<p>The rapid and enormous growths of the power electronics industries have made the flexible AC transmission system (FACTS) devices efficient and viable for utility application to increase power system operation controllability as well as flexibility. This research work presents the application of an evolutionary algorithm namely differential evolution (DE) approach to optimize the location and size of three main types of FACTS devices in order to minimize the power system losses as well as improving the network voltage profile. The utilized system has been reactively loaded beginning from the base to 150% and the system performance is analyzed with and without FACTS devices in order to confirm its importance within the power system. Thyristor controlled series capacitor (TCSC), unified power flow controller (UPFC) and static var compensator (SVC) are used in this research work to monitor the active and reactive power of the carried out system. The adopted algorithm has been examined on IEEE 30-bus test system. The obtained research findings are given with appropriate discussion and considered as quite encouraging that will be valuable in electrical grid restructuring.</p>


Author(s):  
Elutunji Buraimoh ◽  
Funso Kehinde Ariyo ◽  
Micheal Omoigui ◽  
Innocent Ewaen Davidson

Electrical power systems are often required to operate at full loading capacity due to ever increasing demand and transmission line contingencies with limited grid expansion. This results in line overload and operating near system limit, thereby threatening system security. Utilization of existing system can be achieved using Flexible Alternating Current Transmission System (FACTS) devices without violating system limits. This research investigation involves static security assessment of a modelled IEEE 30-bus test system in MATLAB/SIMULINK/PSAT environment. The security status with the incorporation of combined Static Var Compensator (SVC), Thyristor Controlled Series Compensator (TCSC) and Interline Power Flow Controller (IPFC) were determined. Prior to this, Contingency Severity Index (CSI) based on Performance Index (PI) of Voltage and Active Power was employed to determine the optimal location of the FACTS devices. Sequential Quadratic Programming (SQP) was applied to determine the optimal sizing/percentage compensation of FACTS. Subsequently, power system with and without the incorporation of FACTS devices were modelled. The ability of the compensated system to withstand credible transmission line contingencies without violating the normal operating limits (bus voltage and line thermal) was examined and presented. The paper presents how combined SVC/TCSC and an IPFC aided the power system to boost its steady state security in the face of possible line contingencies.


Flexible AC transmission systems (FACTS) devices are integrated into power system networks to control power flow, increase transmission line capability to its thermal limit, and improve the security of transmission systems. Power flow is an important mathematical calculation for planning, operation, and control of power systems network. The focus of the chapter is to explore how to modify Newton-Raphson power flow method to include various FACTS devices such as static VAR compensator (SVC), static synchronous compensator (STATCOM), static synchronous series compensator (SSSC), thyristor-controlled series capacitor (TCSC), thyristor-controlled phase shifter (TCPS), unified power flow controller (UPFC) controllers. This chapter briefly describes the power flow equations of the aforesaid FACTS-based power system network, and how the conventional power flow calculation is systematically extended to include these controllers is also been discussed.


The power flow control is one the important part of power system to maintain power system stability. If the real power and reactive power can be controlled then the automatic control of the power system gives numerous possibilities. The Flexible AC Transmission System (FACTs) are the devices meant for this operation. There are series and shunt type of FACTs devices available. The Unified Power Flow Controller (UPFC) is one of the best devices in FACTs devices in AC power system. The power flows can be controlled in series and shunt connections using the two converters. The power oscillations are common in UPFC when the reference powers are changed. The PI controllers are replaced with PSOA tuned PI controller to reduces the power oscillations and reduces the settling time. The problem is formulated to minimize the settling time of the power value. The series and shunt controllers are tuned with particle swarm optimization algorithm (PSOA) to tune the PI controller parameters available in it. The MATLAB Simulink version 2017b is used here for the analysis and well known UPFC test system with three generators are used here for testing the proposed method. The results show PSOA tuned PI controller provides better oscillation damping with reduced settling time.


Electronics ◽  
2021 ◽  
Vol 10 (2) ◽  
pp. 115
Author(s):  
Nasser Hosseinzadeh ◽  
Asma Aziz ◽  
Apel Mahmud ◽  
Ameen Gargoom ◽  
Mahbub Rabbani

The main purpose of developing microgrids (MGs) is to facilitate the integration of renewable energy sources (RESs) into the power grid. RESs are normally connected to the grid via power electronic inverters. As various types of RESs are increasingly being connected to the electrical power grid, power systems of the near future will have more inverter-based generators (IBGs) instead of synchronous machines. Since IBGs have significant differences in their characteristics compared to synchronous generators (SGs), particularly concerning their inertia and capability to provide reactive power, their impacts on the system dynamics are different compared to SGs. In particular, system stability analysis will require new approaches. As such, research is currently being conducted on the stability of power systems with the inclusion of IBGs. This review article is intended to be a preface to the Special Issue on Voltage Stability of Microgrids in Power Systems. It presents a comprehensive review of the literature on voltage stability of power systems with a relatively high percentage of IBGs in the generation mix of the system. As the research is developing rapidly in this field, it is understood that by the time that this article is published, and further in the future, there will be many more new developments in this area. Certainly, other articles in this special issue will highlight some other important aspects of the voltage stability of microgrids.


Energies ◽  
2019 ◽  
Vol 12 (2) ◽  
pp. 322 ◽  
Author(s):  
Ping He ◽  
Seyed Arefifar ◽  
Congshan Li ◽  
Fushuan Wen ◽  
Yuqi Ji ◽  
...  

The well-developed unified power flow controller (UPFC) has demonstrated its capability in providing voltage support and improving power system stability. The objective of this paper is to demonstrate the capability of the UPFC in mitigating oscillations in a wind farm integrated power system by employing eigenvalue analysis and dynamic time-domain simulation approaches. For this purpose, a power oscillation damping controller (PODC) of the UPFC is designed for damping oscillations caused by disturbances in a given interconnected power system, including the change in tie-line power, the changes of wind power outputs, and others. Simulations are carried out for two sample power systems, i.e., a four-machine system and an eight-machine system, for demonstration. Numerous eigenvalue analysis and dynamic time-domain simulation results confirm that the UPFC equipped with the designed PODC can effectively suppress oscillations of power systems under various disturbance scenarios.


Author(s):  
Anuj Singh ◽  
Dr. Sandeep Sharma ◽  
Karan Sharma ◽  
Flansha Jain ◽  
Shreyanshu Kumar Jena

A Power System is actually a vast system that requires an outstanding plan for maintaining the continual flow of electricity. When a fault occurs at the power system, number of difficulties arises because of transients in system. so to attenuate these transients, power electronics based devices like FACTS are utilized. A unified power flow controller (UPFC) is one among different power electronics controller which can dispense VAR compensation, line impedance control and phase shifting. The thought is to see potential of UPFC to require care of active and reactive power movement within the compensated line (including UPFC) and to shrink the falloff of the bus voltage in case of grounding fault within the cable. power system block consisting of simulink is used for numerical analysis. Simulation outcomes from MATLAB reflects major improvement in the overall system’s behaviour with UPFC in sustain the voltage and power flow even under severe line faults by proper injection of series voltage into the cable at the point of connection. outcomes shows how the UPFC contributes effectively to a faster regaining of the power system to the pre-fault conditions.


Sign in / Sign up

Export Citation Format

Share Document