scholarly journals Hungarian repeat station survey, 2010

2013 ◽  
Vol 55 (6) ◽  
Author(s):  
Péter Kovács ◽  
András Csontos ◽  
Balázs Heilig ◽  
András Koppán

<p>The last Hungarian repeat station survey was completed between October 2010 and February 2011. Declination, inclination and the total field were observed using one-axial DMI fluxgate magnetometer mounted on Zeiss20A theodolite and GSM 19 Overhauser magnetometer. The magnetic elements of the sites were reduced to the epoch of 2010.5 on the basis of the continuous recordings of Tihany Geophysical Observatory. In stations located far from the reference observatory, the observations were carried out in the morning and afternoon in order to decrease the effect of the distant temporal correction. To further increase the accuracy, on-site dIdD variometer has also been installed near the Aggtelek station, in the Baradla cave, during the survey of the easternmost sites. The paper presents the technical details and the results of our last campaign. The improvement of the accuracy of the temporal reduction by the use of the local variometer is also reported.</p>

1984 ◽  
Vol 15 (2) ◽  
pp. 75-77
Author(s):  
Sayyadual Arafin

Author(s):  
Stepan Poluianov ◽  
Ilya Usoskin ◽  
Askar Ibragimov

With the recent electronics upgrade of Antarctic neutron monitors (NMs) DOMC and DOMB in 2019, the Oulu cosmic ray station (Sodankylä Geophysical Observatory, Finland) receives a significantly larger amount of data than before. This has led to a need for an important upgrade of the configuration of servers working at the station. The new configuration has three types of servers: a web-server, a datamaster server and data acquisition machines. The web-server provides a user interface for services of the station: the main website, the GLE database and other services. The datamaster is the main server, which stores all data in raw files and a database. Data acquisition machines are computers that directly receive data from the instruments and send the files farther to the datamaster server. This work describes technical details of the cosmic ray station setup providing reliable and secure data acquisition, handling and publication.


2013 ◽  
Vol 16 (5) ◽  
pp. E295-E297 ◽  
Author(s):  
Joseph Lamelas ◽  
Christos Mihos ◽  
Orlando Santana

In patients with functional mitral regurgitation, the placement of a sling encircling both papillary muscles in conjunction with mitral annuloplasty appears to be a rational approach for surgical correction, because it addresses both the mitral valve and the deformities of the subvalvular mitral apparatus. Reports in the literature that describe the utilization of this technique are few, and mainly involve a median sternotomy approach. The purpose of this communication is to describe the technical details of performing this procedure via a minimally invasive approach.


2017 ◽  
Vol 2017 (45) ◽  
pp. 83-89
Author(s):  
A.A. Marusenkov ◽  

Using dedicated high-frequency measuring system the distribution of the Barkhausen jumps intensity along a reversal magnetization cycle was investigated for low noise fluxgate sensors of various core shapes. It is shown that Barkhausen (reversal magnetization) noise intensity is strongly inhomogeneous during an excitation cycle. In the traditional second harmonic fluxgate magnetometers the signals are extracted in the frequency domain, as a result, some average value of reversal magnetization noises is contributed to the output signals. In order to fit better the noise shape and minimize its transfer to the magnetometer output the new approach for demodulating signals of these sensors is proposed. The new demodulating method is based on information extraction in the time domain taking into account the statistical properties of cyclic reversal magnetization noises. This approach yields considerable reduction of the fluxgate magnetometer noise in comparison with demodulation of the signal filtered at the second harmonic of the excitation frequency.


2018 ◽  
Vol 69 (9) ◽  
pp. 2407-2410
Author(s):  
Dan Perju Dumbrava ◽  
Carmen Corina Radu ◽  
Sofia David ◽  
Tatiana Iov ◽  
Catalin Jan Iov ◽  
...  

Considering the growing number of requests from the criminal investigations authorities addressed to the institutions of legal medicine, testing of blood alcohol concentration both in the living person and in the corpse, we believe that a presentation of the two methods which are used in our country, is a topic of interest at present. The purpose of this article is to provide the reader with the technical details on how blodd alcohol concentration is realised by means of the gas chromatographic method and the classical one, (Cordebard modified by D. Banciu and I. Droc) respectively. Another purpose of this article is to also show, in a comparative way, the elements that make the gas chromatographic method superior to the former one.


2011 ◽  
Vol 3 (5) ◽  
pp. 1-8 ◽  
Author(s):  
S. V. Anisimov ◽  
E. M. Dmitriev ◽  
K. V. Aphinogenov ◽  
A. V. Guriev

Sign in / Sign up