scholarly journals Correlation between alteration of enamel roughness and tooth color

Author(s):  
WF Vieira-Junior ◽  
I Vieira ◽  
GMB Ambrosano ◽  
FHB Aguiar ◽  
DANL Lima
Keyword(s):  
2020 ◽  
Vol 45 (6) ◽  
pp. 589-597
Author(s):  
BGS Casado ◽  
EP Pellizzer ◽  
JR Souto Maior ◽  
CAA Lemos ◽  
BCE Vasconcelos ◽  
...  

Clinical Relevance The use of laser light during bleaching will not reduce the incidence or severity of sensitivity and will not increase the degree of color change compared with nonlaser light sources. SUMMARY Objective: To evaluate whether the use of laser during in-office bleaching promotes a reduction in dental sensitivity after bleaching compared with other light sources. Methods: The present review was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) and is registered with PROSPERO (CDR42018096591). Searches were conducted in the PubMed/Medline, Web of Science, and Cochrane Library databases for relevant articles published up to August 2018. Only randomized clinical trials among adults that compared the use of laser during in-office whitening and other light sources were considered eligible. Results: After analysis of the texts retrieved during the database search, six articles met the eligibility criteria and were selected for the present review. For the outcome dental sensitivity, no significant difference was found favoring any type of light either for intensity (mean difference [MD]: −1.60; confidence interval [CI]: −3.42 to 0.22; p=0.09) or incidence (MD: 1.00; CI: 0.755 to 1.33; p=1.00). Regarding change in tooth color, no significant differences were found between the use of the laser and other light sources (MD: −2.22; CI: −6.36 to 1.93; p=0.29). Conclusions: Within the limitations of the present study, laser exerts no influence on tooth sensitivity compared with other light sources when used during in-office bleaching. The included studies demonstrated that laser use during in-office bleaching may have no influence on tooth color change.


Author(s):  
Seoul-Hee Nam ◽  
Byul Bo Ra Choi ◽  
Gyoo-Cheon Kim

Various light sources have been applied to enhance the bleaching effect. This study was to identify the histological evaluation in oral soft tissues, as well as tooth color change after tooth bleaching by nonthermal atmospheric pressure plasma (NAPP). Nine New Zealand adult female rabbits were randomly divided into three groups (n = 3): group 1 received no treatment; group 2 was treated with NAPP and 15% carbamide peroxide (CP), which contains 5.4% H2O2, and group 3 was treated with 15% CP without NAPP. Color change (ΔE) was measured using the Shade Eye NCC colorimeter. Animals were euthanized one day later to analyze the histological responses occurring in oral soft tissues, including pulp, gingiva, tongue, buccal mucosa, and hard and soft palates. Changes in all samples were analyzed by hematoxylin and eosin staining and Masson’s trichrome. Teeth treated with plasma showed higher ΔE than that obtained with bleaching agents alone. Overall, the histological characteristics observed no appreciable changes. The combinational treatment of plasma had not indicated inflammatory responses as well as thermal damages. NAPP did not cause histological damage in oral soft tissues during tooth bleaching. We suggest that NAPP could be a novel alternative energy source to conventional light sources for tooth bleaching.


Author(s):  
Ralf Krug ◽  
C. Ortmann ◽  
S. Reich ◽  
B. Hahn ◽  
G. Krastl ◽  
...  

Abstract Objectives To assess tooth discoloration induced by different hydraulic calcium silicate-based cements (HCSCs), including effects of blood and placement method. Materials and methods Eighty bovine teeth cut to a length of 18 mm (crown 8 mm, root 10 mm) were randomly assigned to 10 groups (n = 8), receiving orthograde apical plug treatment (APT). Apical plugs were 4 mm in length and made of ProRoot MTA (Dentsply), Medcem MTA (Medcem), TotalFill BC RRM Fast Set Putty (Brasseler), or Medcem Medical Portland Cement (Medcem) plus bismuth oxide (Bi2O3) with and without bovine blood. Further, orthograde (with or without preoperative adhesive coronal dentin sealing) and retrograde APT were compared. Teeth were obturated with gutta-percha and sealer, sealed with composite and stored in distilled water. Tooth color was measured on apical plug, gutta-percha/sealer, and crown surface before treatment versus 24 h, 1, 3, 6, 12, and 24 months after treatment by spectrophotometry. Color difference (ΔE) values were calculated and analyzed by Shapiro–Wilk test, ANOVA with post hoc tests, Friedman test, t test, and post hoc tests with Bonferroni correction (α = .05). Results Tooth discoloration occurred in all groups with no significant differences between HCSCs (p > .05). After 24 months, color changes were prominent on roots but insignificant on crowns. Blood contamination induced a significantly decreased luminescence (p < .05). Blood had a stronger impact on tooth color than Bi2O3. No relevant effects of retrograde placement (p > .05) or preoperative dentin sealing (p > .05) were detected. Conclusions Apical plugs of the tested HCSCs cause discoloration of bovine roots, but not discoloration of bovine tooth crowns within a 24-month period. Clinical relevance APT should be performed carefully while avoiding direct contact with the coronal dentin, and in that case no aesthetic impairments occur.


Polymers ◽  
2021 ◽  
Vol 13 (12) ◽  
pp. 1949
Author(s):  
Ling Ding ◽  
Wei Lu ◽  
Jiaqi Zhang ◽  
Chuncheng Yang ◽  
Guofeng Wu

Literature has reported the successful use of 3D printed polyetheretherketone (PEEK) to fabricate human body implants and oral prostheses. However, the current 3D printed PEEK (brown color) cannot mimic the vivid color of oral tissues and thus cannot meet the esthetical need for dental application. Therefore, titanium dioxide (TiO2) and ferric oxide (Fe2O3) were incorporated into PEEK to prepare a series of tooth-color and gingival-color PEEK composites in this study. Through color measurements and mechanical tests, the color value and mechanical performance of the 3D printed PEEK composites were evaluated. In addition, duotone PEEK specimens were printed by a double nozzle with an interface between tooth-color and gingival-color parts. The mechanical performance of duotone PEEK with two different interfaces (horizontal and vertical) was investigated. With the addition of TiO2 and Fe2O3, the colors of 3D printed PEEK composites become closer to that of dental shade guides. 3D printed PEEK composites generally demonstrated superior tensile and flexural properties and hence have great potential in the dental application. In addition, duotone 3D printed PEEK with a horizontal interfacial orientation presented better mechanical performance than that with a vertical one.


Author(s):  
Hüseyin Hatırlı ◽  
Emine Şirin Karaarslan ◽  
Bilal Yaşa ◽  
Enes Kılıç ◽  
Ayla Yaylacı
Keyword(s):  

2016 ◽  
Vol 20 (2) ◽  
pp. 104-110 ◽  
Author(s):  
A. Dilek Nalbant ◽  
Yeşim Göknur Babaç ◽  
İrem Türkcan ◽  
Kaan Yerliyurt ◽  
Cihan Akçaboy ◽  
...  

Summary Aim: Although visual color determination is the most frequently applied method in dentistry, instrumental color analysis offers advantages like objectivity, measurability and rapidity. The aim of this study was to evaluate the natural teeth color in teeth without any restoration visually, and by using a computerized shade measuring and analyzing system in the population.Materials and Methods: 202 patients were inspected. Before instrumental shade matching visual matching was done by the inspector with Vitapan 3D Master Shade Guide in the day light. Images were taken with computerized shade measuring and analyzing system from patients’ natural right or left maxillary incisors and canines without any restoration. Then these images were evaluated by the original software of its own.Results: Value differences between visual and instrumental shade matching were statistically significant. Darker value levels were obtained with instrumental measurement. The distribution of hue was more reddish in instrumental examination than visual examination. Significant difference was found at cervical and middle third of the tooth in both visual and instrumental determination of chroma. Chroma of the tooth was higher at these two regions in visual assessment.Conclusions: Teeth colors were distributed more uniform in visual shade matching compared to instrumental matching. However, some teeth shades were more common in instrumental matching. Value scores were found higher with instrumental shade matching. Individual selection of shades for each tooth and different regions of a tooth instead of a single color is considered to be a factor to increase the success of the restoration.


Sign in / Sign up

Export Citation Format

Share Document