scholarly journals Biomechanical Analysis for Patients having Lower Limb Disorders using the 3-D Video Images and a Foot-Force-Plate Sensor System.

Author(s):  
MASAKO TSURUOKA
2019 ◽  
Vol 19 (06) ◽  
pp. 1950050
Author(s):  
M. T. KARIMI ◽  
R. B. TAHMASEBI ◽  
B. SATVATI ◽  
F. FATOYE

Flat foot is the most common foot disorder that influences the alignment of the lower limb structure. It is controversial whether the use of foot insole influences kinetic and kinematic of the leg or not. Therefore, this study investigated the influence of foot insole on the gait performance in subjects with flat foot disorder. A group of flat foot subject was recruited into this study (the number of subjects was 15). The motion of the leg joints was determined using the Qualysis motion analysis system. Moreover, the force applied on the lower limb was recorded by a Kistler force plate. The range of motion of the lower limb joints, the moments applied on the lower limb joints and force transmitted through the leg were the parameters used in this study. The difference between these parameters during walking with and without insole was evaluated using the paired [Formula: see text]-test. Significant value was set at [Formula: see text]. There was no significant difference between the range of motion of ankle joint while walking with and without insole. However, the medial directed force applied on the leg decreased significantly [Formula: see text]. The use of foot insole did not influence the moments transmitted through the hip and knee joints. The walking speed of the subjects improved while walking with foot insole. Use of foot insole influenced the magnitude of the force applied on the leg and the adductor moment of ankle joint due to its influence on foot alignment. As the walking speed of the improved subjects follows the use of insole, it can be concluded that it may have a positive effects on the performance of flat foot subjects.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1153
Author(s):  
Franz Konstantin Fuss ◽  
Asliza Ahmad ◽  
Adin Ming Tan ◽  
Rizal Razman ◽  
Yehuda Weizman

Hard-shell thoracolumbar sacral orthoses (TLSOs) are used for treating idiopathic scoliosis, a deformation of the spine with a sideways curvature. The pressure required inside the TLSO for ideal corrective results remains unclear. Retrofitting TLSOs with commercially available pressure measurement systems is expensive and can only be performed in a laboratory. The aim of this study was to develop a cost-effective but accurate pressure sensor system for TLSOs. The sensor was built from a piezoresistive polymer, placed between two closed-cell foam liners, and evaluated with a material testing machine. Because foams are energy absorbers, the pressure-conductance curve was affected by hysteresis. The sensor was calibrated on a force plate with the transitions from loading to unloading used to establish the calibration curve. The root mean square error was 12% on average within the required pressure range of 0.01–0.13 MPa. The sensor reacted to the changing pressure during breathing and different activities when tested underneath a chest belt at different tensions. The peak pressure reached 0.135 MPa. The sensor was further tested inside the scoliosis brace during different activities. The measured pressure was 0.014–0.124 MPa. The results from this study enable cheaper and mobile systems to be used for clinical studies on the comfort and pressure of braces during daily activities.


2007 ◽  
Vol 342-343 ◽  
pp. 621-624
Author(s):  
Hyeon Ki Choi ◽  
Si Yeol Kim ◽  
Won Hak Cho

We investigated the relationship between kinematic and kinetic characteristics of foot joints resisting ground reaction force (GRF). Passive elastic characteristics of joint were obtained from the experiment using three cameras and one force plate. The relationship between joint angle and moment was mathematically modeled by using least square method. The calculated ranges of motion were 7o for TM joint, 4o for TT joint and 20o for MP joint. With the model that relates joint angle and plantar pressure, we could get the kinematic data of the joints which are not available from conventional motion analysis. The model can be used not only for biomechanical analysis which simulates gait but also for the clinical evaluations.


Author(s):  
Sergey Fedorovich Jatsun ◽  
Andrey Yatsun ◽  
Sergei Savin

In this chapter, the lower limb exoskeleton is studied. The roles of the exoskeleton both as a measurement device for studying human locomotion and as an assistive device that restores the human ability to walk are discussed. Particular attention is given to the investigation of the role of the pressure sensors and other devices that allow us to measure normal reactions at the contact points with the supporting surface and also detect these contacts. The way the geometry of the supporting surface affects the sensors system of the robot is considered, and new designs for feet sensor system are proposed. These include elastic foot, a foot with actuated sensors, and a foot with spring-damper systems.


2019 ◽  
Vol 2019 ◽  
pp. 1-8 ◽  
Author(s):  
Xiaoxue Zhao ◽  
Shudong Li

Most of the previous studies have been focused on the upper limb biomechanical characteristic in the clear stroke among different level badminton players, but research on the lower limb is limited. The aim of this study is to explore the lower limb kinematics and foot pressure in the backcourt forehand clear stroke among badminton players to give theoretical reference in teaching and answer the questions occurring in the process of learning the actions. Ten professional badminton players (PP) and ten amateur players (AP) were recruited in this study. Plantar pressure analyses indicated that both the PP and the AP were in contact with the ground over the forefoot without the midfoot and heel. The work suggests that when designing professional badminton sports shoes, the designers should focus on strengthening footwear resistance in the metatarsal and forefoot area, especially the first metatarsal area, to meet the requirement of the movement demand and take the badminton movement characteristics in different regions of the design. The peak ankle dorsiflexion, eversion, and internal rotation angle levels of the AP are lower than those of the PP. It is important for the AP group to enhance their ankle strength to prevent injury and improve performance.


Ergonomics ◽  
2000 ◽  
Vol 43 (9) ◽  
pp. 1405-1429 ◽  
Author(s):  
X. Wang ◽  
J. P. Verriest ◽  
B. Lebreton-Gadegbeku ◽  
Y. Tessier ◽  
J. Trasbot