Development of Electric Power Control using the Capacitance Characteristics of the Fuel Cell

2011 ◽  
Vol 4 (1) ◽  
pp. 1879-1887 ◽  
Author(s):  
Hiroyuki Imanishi ◽  
Kota Manabe ◽  
Tomoya Ogawa ◽  
Yasuhiro Nonobe
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Shofu Matsuda ◽  
Yuuki Niitsuma ◽  
Yuta Yoshida ◽  
Minoru Umeda

AbstractGenerating electric power using CO2 as a reactant is challenging because the electroreduction of CO2 usually requires a large overpotential. Herein, we report the design and development of a polymer electrolyte fuel cell driven by feeding H2 and CO2 to the anode (Pt/C) and cathode (Pt0.8Ru0.2/C), respectively, based on their theoretical electrode potentials. Pt–Ru/C is a promising electrocatalysts for CO2 reduction at a low overpotential; consequently, CH4 is continuously produced through CO2 reduction with an enhanced faradaic efficiency (18.2%) and without an overpotential (at 0.20 V vs. RHE) was achieved when dilute CO2 is fed at a cell temperature of 40 °C. Significantly, the cell generated electric power (0.14 mW cm−2) while simultaneously yielding CH4 at 86.3 μmol g−1 h−1. These results show that a H2-CO2 fuel cell is a promising technology for promoting the carbon capture and utilization (CCU) strategy.


Author(s):  
Giulio Vialetto ◽  
Marco Noro ◽  
Masoud Rokni

In this paper, a new heat recovery for a microcogeneration system based on solid oxide fuel cell and air source heat pump (HP) is presented with the main goal of improving efficiency on energy conversion for a residential building. The novelty of the research work is that exhaust gases after the fuel cell are first used to heat water for heating/domestic water and then mixed with the external air to feed the evaporator of the HP with the aim of increasing energy efficiency of the latter. This system configuration decreases the possibility of freezing of the evaporator as well, which is one of the drawbacks for air source HP in Nordic climates. A parametric analysis of the system is developed by performing simulations varying the external air temperature, air humidity, and fuel cell nominal power. Coefficient of performance (COP) can increase more than 100% when fuel cell electric power is close to its nominal (50 kW), and/or inlet air has a high relative humidity (RH) (close to 100%). Instead, the effect of mixing the exhausted gases with air may be negative (up to −25%) when fuel cell electric power is 20 kW and inlet air has 25% RH. Thermodynamic analysis is carried out to prove energy advantage of such a solution with respect to a traditional one, resulting to be between 39% and 44% in terms of primary energy. The results show that the performance of the air source HP increases considerably during cold season for climates with high RH and for users with high electric power demand.


Energies ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6611
Author(s):  
Kazui Yoshida ◽  
Hom B. Rijal ◽  
Kazuaki Bohgaki ◽  
Ayako Mikami ◽  
Hiroto Abe

A residential cogeneration system (CGS) is highlighted because of its efficient energy usage on both the supplier and consumer sides. It generates electricity and heat simultaneously; however, there is insufficient information on the efficiency according to the condition of usage. In this study, we analysed the performance data measured by the home energy management system (HEMS) and the lifestyle data of residents in a condominium of 356 flats where fuel cell CGS was installed in each flat. The electricity generated by CGS contributed to an approximately 12% reduction in primary energy consumption and CO2 emission, and the rate of generation by the CGS in the electric power demand (i.e., contribution rate) was approximately 38%. The electricity generation was mainly affected by the use of electricity up to 4 MWh/household/year. Gas or water use also impacted electric power generation, with water use as the primary factor affecting the contribution rate. Electric power generation changes monthly, mainly based on the water temperature. From these results, we confirmed that a CGS has substantial potential to reduce energy consumption and CO2 emission in condominiums. Thus, it is recommended for installation of fuel cell CGS in existing and new buildings to contribute to the energy-saving target of the Japanese Government in the residential sector.


Sign in / Sign up

Export Citation Format

Share Document