scholarly journals Influence of Detection Methods in Characterizing Escherichia coli O157:H7 in Raw Goat Meat Using Conventional and Molecular Methods

2016 ◽  
Vol 21 (4) ◽  
pp. 261-264 ◽  
Author(s):  
ZAJEBA TABASHSUM ◽  
MAFRUHA NAZNEEN ◽  
C. R. AHSAN ◽  
M. L. BARI ◽  
M. YASMIN
2011 ◽  
Vol 74 (1) ◽  
pp. 6-12 ◽  
Author(s):  
F. SAVOYE ◽  
P. FENG ◽  
C. ROZAND ◽  
M. BOUVIER ◽  
A. GLEIZAL ◽  
...  

Enterohemorrhagic Escherichia coli O157:H7 is an important pathogen associated with infections caused by consumption of undercooked raw meat. Sensitive and rapid detection methods for E. coli O157:H7 are essential for the meat industry to ensure a safe meat supply. This study was conducted to compare the sensitivity of the VIDAS ultraperformance E. coli test (ECPT UP) with a noncommercial real-time (RT) PCR method and the U.S. Department of Agriculture, Food Safety and Inspection Service (USDA-FSIS) reference method for detecting E. coli O157:H7 in raw ground beef. Optimal enrichment times and the efficacy of testing different types of raw meat, either as individual samples (25 g) or as composites (375 g), were examined. For 25-g samples of each type of raw ground beef tested, 6 h of enrichment was sufficient for both the VIDAS ECPT UP and RT-PCR methods, but for 375-g samples, 24 h of enrichment was required. Both the VIDAS ECPT UP and RT-PCR methods produced results similar to those obtained with the USDA-FSIS reference method after 18 to 24 h of enrichment. The primer specificity of the RT-PCR assay and the highly specific phage ligand used in the VIDAS ECPT UP for target recognition enabled the detection of low levels of E. coli O157:H7 in 25 g of various types of raw ground beef. The tests also allowed the detection of E. coli O157:H7 in composite raw ground beef and trimmings in samples of up to 375 g.


2016 ◽  
Vol 219 ◽  
pp. 64-70 ◽  
Author(s):  
Bavo Verhaegen ◽  
Inge Van Damme ◽  
Marc Heyndrickx ◽  
Nadine Botteldoorn ◽  
Mohamed Elhadidy ◽  
...  

2014 ◽  
Vol 77 (6) ◽  
pp. 972-976 ◽  
Author(s):  
K. J. WILLIAMS ◽  
M. P. WARD ◽  
O. DHUNGYEL ◽  
L. VAN BREDA

The need to quantify the potential human health risk posed by the bovine reservoir of Escherichia coli O157 has led to a wealth of prevalence studies and improvements in detection methods over the last two decades. Rectoanal mucosal swabs have been used for the detection of E. coli O157 fecal shedding, colonized animals, and those predisposed to super shedding. We conducted a longitudinal study to compare the detection of E. coli O157 from feces and rectoanal mucosal swabs (RAMS) from a cohort of dairy heifers. We collected 820 samples that were tested by immunomagnetic separation of both feces and RAMS. Of these, 132 were detected as positive for E. coli O157 from both samples, 66 were detected as positive from RAMS only, and 117 were detected as positive from feces only. The difference in results between the two sample types was statistically significant (P < 0.001). The relative sensitivities of detection by immunomagnetic separation were 53% (confidence interval, 46.6 to 59.3) from RAMS and 67% (confidence interval, 59.6 to 73.1) from fecal samples. No association between long-term shedding (P = 0.685) or super shedding (P = 0.526) and detection by RAMS only was observed.


1999 ◽  
Vol 46 (1) ◽  
pp. 27-36 ◽  
Author(s):  
Youichi Onoue ◽  
Hirotaka Konuma ◽  
Hiroshi Nakagawa ◽  
Yukiko Hara-Kudo ◽  
Toshiharu Fujita ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document