scholarly journals Safety and efficacy of amplatzer duct occluder for percutaneous closure of ventricular septal defects with tunnel shape aneurysm: Medium term follow up

2013 ◽  
Vol 03 (02) ◽  
pp. 228-233 ◽  
Author(s):  
Muhammad Dilawar ◽  
Zaheer Ahmad
Author(s):  
Anh Binh Ho

Transcatheter closure of perimembranous and muscular ventricular septal defects: short and medium-term outcome ABSTRACT Objective: This study attempted to report the initial results: the safety and efficacy of transcatheter closure of ventricular septal defects (VSDs) at Hue Central Hospital with the short and medium-term follow-up. Methods: From September 2012 to May 2017, a total of 36 patients with perimembranous or muscular VSD underwent an attempt of transcatheter closure at the Department of Interventional Cardiology, Hue Central Hospital. Results: 14 males and 26 females participated in this study, with the age of 17,29  13.72 and 24.23  12.32 respectively. Among these patients, 19.44% of them were under 6-year-old; 72.22% had perimembranous VSDs, 27.78% had muscular VSDs, and 33.33% had aneurysm. The distance to AV was 5.62 ± 4.32 mm. The device size was 15.31± 8.12 mm. Procedures lasted for 57.17 ± 26.5 min with 15.31± 8.12 min of exposure. The complete closure rates by transthoracic echocardiography after 24 hours, 1 month, 3 months and 6 months (transthoracic) were 94.44%; 94.44% ; 97.22% and 100%, respectively. Mean time of follow-up was 11.92 ± 8.36 (3-38) months. Success rate was 97.22% and no death occurred. There was 1 case of hematuria, lasting 1 month; no Atrioventricular (AV) block. Conclusions: Transcatheter closure of VSDs is a novel, feasible and safe technique with high success rate (97.22%). The transcather approach provides a less invasive alternative than surgical closure and might become the first choice treatment in selected patients. Key words: transcatheter closure, ventricular septal defects


2020 ◽  
Vol 20 (4) ◽  
pp. e352-359
Author(s):  
Khalfan S. Al Senaidi ◽  
Salim Al Maskary ◽  
Eapen Thomas ◽  
Boris Dimitrov ◽  
Abdullah Al Farqani

Objectives: This study aimed to review the experience with percutaneous closure of ventricular septal defects (VSDs) at the National Heart Center (NHC) in Muscat, Oman. Methods: This retrospective study was conducted from November 2008 to December 2017. Patients’ electronic medical records were reviewed to identify their clinical, imaging and interventional data before and after the procedure and on the last followup. Results: A total of 116 patients, the majority of which were female (58%), underwent 118 percutaneous procedures for VSD closure at a median age of 3.54 years (range: 0.25–33 years) and a median weight of 12 kg (range: 3.5–78 kg). The mean diameter of the VSDs as determined by transoesophageal echocardiogram was 5.6 ± 1.9 mm (n = 105). The commonest type of VSD was perimembranous (n = 75, 63.5%). Devices were successfully placed during 111 (94.1%) procedures in 109 (94.0%) patients, with the commonest device being a Amplatzer™ duct occluder I (St. Jude Medical, Little Canada, Minnesota, USA; n = 39, 35.1%). There was no mortality. Early major cardiac complications occurred in six patients (5.5%) with device embolisation being the commonest (n = 4, 3.7%). The median follow-up period was 19 months (range: 1–84 months) in 89 (81.7%) of the patients. One patient (0.9%) required a permanent pacemaker for a complete heart block. Conclusion: This study has demonstrated a good rate of VSD closure with low morbidity and no mortality using the percutaneous approach with different devices. Long-term follow-up is needed to specifically evaluate the function of adjacent structures and the long-term effects on conduction systems. Keywords: Ventricular Septal Defect; Percutaneous Coronary Intervention; Amplatzer Occluder Device; Vascular Closure Device; Heart Block; Oman.  


Sign in / Sign up

Export Citation Format

Share Document