scholarly journals Current Trends in the detection of Acute HIV Infection among Blood Donors: Reliability of Pooled Nucleic Acid Amplification Technology and the Need for Population Specific Algorithms: A Systematic Review

2015 ◽  
Vol 07 (03) ◽  
Author(s):  
Abubakar AG Ozumba PJ ◽  
Winter J Buttner P
AIDS ◽  
2007 ◽  
Vol 21 (5) ◽  
pp. 653-655 ◽  
Author(s):  
Salim S Abdool Karim ◽  
Koleka Mlisana ◽  
Ayesha BM Kharsany ◽  
Carolyn Williamson ◽  
Cheryl Baxter ◽  
...  

2013 ◽  
Vol 188 (1-2) ◽  
pp. 153-160 ◽  
Author(s):  
Lei Chang ◽  
Linan Song ◽  
David R. Fournier ◽  
Cheuk W. Kan ◽  
Purvish P. Patel ◽  
...  

2015 ◽  
Vol 61 (11) ◽  
pp. 1372-1380 ◽  
Author(s):  
Carlos Cabrera ◽  
Lei Chang ◽  
Mars Stone ◽  
Michael Busch ◽  
David H Wilson

Abstract BACKGROUND Nucleic acid testing (NAT) has become the standard for high sensitivity in detecting low levels of virus. However, adoption of NAT can be cost prohibitive in low-resource settings where access to extreme sensitivity could be clinically advantageous for early detection of infection. We report development and preliminary validation of a simple, low-cost, fully automated digital p24 antigen immunoassay with the sensitivity of quantitative NAT viral load (NAT-VL) methods for detection of acute HIV infection. METHODS We developed an investigational 69-min immunoassay for p24 capsid protein for use on a novel digital analyzer on the basis of single-molecule-array technology. We evaluated the assay for sensitivity by dilution of standardized preparations of p24, cultured HIV, and preseroconversion samples. We characterized analytical performance and concordance with 2 NAT-VL methods and 2 contemporary p24 Ag/Ab combination immunoassays with dilutions of viral isolates and samples from the earliest stages of HIV infection. RESULTS Analytical sensitivity was 0.0025 ng/L p24, equivalent to 60 HIV RNA copies/mL. The limit of quantification was 0.0076 ng/L, and imprecision across 10 runs was <10% for samples as low as 0.09 ng/L. Clinical specificity was 95.1%. Sensitivity concordance vs NAT-VL on dilutions of preseroconversion samples and Group M viral isolates was 100%. CONCLUSIONS The digital immunoassay exhibited >4000-fold greater sensitivity than contemporary immunoassays for p24 and sensitivity equivalent to that of NAT methods for early detection of HIV. The data indicate that NAT-level sensitivity for acute HIV infection is possible with a simple, low-cost digital immunoassay.


2007 ◽  
Vol 17 (3) ◽  
pp. 200-204 ◽  
Author(s):  
P. S. P. Scuracchio ◽  
M. C. C. Poli ◽  
M. M. M. Lemos ◽  
A. G. Oliveira Filho ◽  
N. A. Salles ◽  
...  

AIDS ◽  
2015 ◽  
Vol 29 (7) ◽  
pp. 793-800 ◽  
Author(s):  
Mark S. De Souza ◽  
Nittaya Phanuphak ◽  
Suteeraporn Pinyakorn ◽  
Rapee Trichavaroj ◽  
Supanit Pattanachaiwit ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document