Synthetic cannabinoids in biological specimens: a review of current analytical methods and sample preparation techniques

Bioanalysis ◽  
2018 ◽  
Vol 10 (19) ◽  
pp. 1609-1623 ◽  
Author(s):  
Tiago Rosado ◽  
Joana Gonçalves ◽  
Ângelo Luís ◽  
Sara Malaca ◽  
Sofia Soares ◽  
...  
Bioanalysis ◽  
2020 ◽  
Vol 12 (21) ◽  
pp. 1557-1595
Author(s):  
Ana Y Simão ◽  
Mónica Antunes ◽  
Hernâni Marques ◽  
Tiago Rosado ◽  
Sofia Soares ◽  
...  

One of the problems associated with the consumption of new psychoactive substances is that in most scenarios of acute toxicity the possibility of quick clinical action may be impaired because many screening methods are not responsive to them, and laboratories are not able to keep pace with the appearance of new substances. For these reasons, developing and validating new analytical methods is mandatory in order to efficiently face those problems, allowing laboratories to be one step ahead. The goal of this work is to perform a critical review regarding bionalytical methods that can be used for the determination of new psychoactive substances (phenylethylamines, cathinones, synthetic cannabinoids, opioids, benzodiazepines, etc), particularly concerning sample preparation techniques and associated analytical methods.


Author(s):  
Earl R. Walter ◽  
Glen H. Bryant

With the development of soft, film forming latexes for use in paints and other coatings applications, it became desirable to develop new methods of sample preparation for latex particle size distribution studies with the electron microscope. Conventional latex sample preparation techniques were inadequate due to the pronounced tendency of these new soft latex particles to distort, flatten and fuse on the substrate when they dried. In order to avoid these complications and obtain electron micrographs of undistorted latex particles of soft resins, a freeze-dry, cold shadowing technique was developed. The method has now been used in our laboratory on a routine basis for several years.The cold shadowing is done in a specially constructed vacuum system, having a conventional mechanical fore pump and oil diffusion pump supplying vacuum. The system incorporates bellows type high vacuum valves to permit a prepump cycle and opening of the shadowing chamber without shutting down the oil diffusion pump. A baffeled sorption trap isolates the shadowing chamber from the pumps.


Author(s):  
P. B. Basham ◽  
H. L. Tsai

The use of transmission electron microscopy (TEM) to support process development of advanced microelectronic devices is often challenged by a large amount of samples submitted from wafer fabrication areas and specific-spot analysis. Improving the TEM sample preparation techniques for a fast turnaround time is critical in order to provide a timely support for customers and improve the utilization of TEM. For the specific-area sample preparation, a technique which can be easily prepared with the least amount of effort is preferred. For these reasons, we have developed several techniques which have greatly facilitated the TEM sample preparation.For specific-area analysis, the use of a copper grid with a small hole is found to be very useful. With this small-hole grid technique, TEM sample preparation can be proceeded by well-established conventional methods. The sample is first polished to the area of interest, which is then carefully positioned inside the hole. This polished side is placed against the grid by epoxy Fig. 1 is an optical image of a TEM cross-section after dimpling to light transmission.


Author(s):  
Ng Sea Chooi ◽  
Chor Theam Hock ◽  
Ma Choo Thye ◽  
Khoo Poh Tshin ◽  
Dan Bockelman

Abstract Trends in the packaging of semiconductors are towards miniaturization and high functionality. The package-on-package(PoP) with increasing demands is beneficial in cost and space saving. The main failure mechanisms associated with PoP technology, including open joints and warpage, have created a lot of challenges for Assembly and Failure Analysis (FA). This paper outlines the sample preparation process steps to overcome the challenges to enable successful failure analysis and optical probing.


Author(s):  
Jason H. Lagar ◽  
Rudolf A. Sia

Abstract Most Wafer Level Chip Scale Package (WLCSP) units returned by customers for failure analysis are mounted on PCB modules with an epoxy underfill coating. The biggest challenge in failure analysis is the sample preparation to remove the WLCSP device from the PCB without inducing any mechanical defect. This includes the removal of the underfill material to enable further electrical verification and fault isolation analysis. This paper discusses the evaluations conducted in establishing the WLCSP demounting process and removal of the epoxy underfill coating. Combinations of different sample preparation techniques and physical failure analysis steps were evaluated. The established process enabled the electrical verification, fault isolation and further destructive analysis of WLCSP customer returns mounted on PCB and with an epoxy underfill coating material. This paper will also showcase some actual full failure analysis of WLCSP customer returns where the established process played a vital role in finding the failure mechanism.


Author(s):  
Hyoung H. Kang ◽  
Michael A. Gribelyuk ◽  
Oliver D. Patterson ◽  
Steven B. Herschbein ◽  
Corey Senowitz

Abstract Cross-sectional style transmission electron microscopy (TEM) sample preparation techniques by DualBeam (SEM/FIB) systems are widely used in both laboratory and manufacturing lines with either in-situ or ex-situ lift out methods. By contrast, however, the plan view TEM sample has only been prepared in the laboratory environment, and only after breaking the wafer. This paper introduces a novel methodology for in-line, plan view TEM sample preparation at the 300mm wafer level that does not require breaking the wafer. It also presents the benefit of the technique on electrically short defects. The methodology of thin lamella TEM sample preparation for plan view work in two different tool configurations is also presented. The detailed procedure of thin lamella sample preparation is also described. In-line, full wafer plan view (S)TEM provides a quick turn around solution for defect analysis in the manufacturing line.


2020 ◽  
Vol 16 ◽  
Author(s):  
Mustafa Çelebier ◽  
Merve Nenni

Background: Metabolomics has gained importance in clinical applications over the last decade. Metabolomics studies are significant because the systemic metabolome is directly affected by disease conditions. Metabolome-based biomarkers are actively being developed for early diagnosis and to indicate the stage of specific diseases. Additionally, understanding the effect of an intervention on a living organism at the molecular level is a crucial strategy for understanding novel or unexpected biological processes. Results: The simultaneous improvements in advanced analytical techniques, sample preparation techniques, computer technology, and databank contents has enabled more valuable scientific information to be gained from metabolomics than ever before. With over 15,000 known endogenous metabolites, there is no single analytical technique capable of analyzing the whole metabolome. However, capillary electrophoresis-mass spectrometry (CE-MS) is a unique technique used to analyze an important portion of metabolites not accessible by liquid chromatography or gas chromatography techniques. The analytical capability of CE, combined with recent sample preparation techniques focused on extracting polar-ionic compounds, make CE-MS a perfect technique for metabolomic studies. Conclusion: Here, previous reviews of CE-MS based metabolomics are evaluated to highlight recent improvements in this technique. Specifically, we review papers from the last two years (2018 and 2019) on CE-MS based metabolomics. The current situation and the challenges facing metabolomic studies are discussed to reveal the high potential of CE-MS for further studies, especially in biomarker development studies.


Molecules ◽  
2021 ◽  
Vol 26 (2) ◽  
pp. 382
Author(s):  
Barbara Pacholczyk-Sienicka ◽  
Grzegorz Ciepielowski ◽  
Łukasz Albrecht

Spices and herbs are among the most commonly adulterated food types. This is because spices are widely used to process food. Spices not only enhance the flavor and taste of food, but they are also sources of numerous bioactive compounds that are significantly beneficial for health. The healing effects of spices are connected with their antimicrobial, anti-inflammatory and carminative properties. However, regular consumption of adulterated spices may cause fatal damage to our system because adulterants in most cases are unhealthy. For that reason, the appropriate analytical methods are necessary for quality assurance and to ensure the authenticity of spices. Spectroscopic methods are gaining interest as they are fast, require little or no sample preparation, and provide rich structural information. This review provides an overview of the application of NMR spectroscopy combined with chemometric analysis to determine the quality and adulteration of spices.


Sign in / Sign up

Export Citation Format

Share Document