THE EFFECT OF MIXING STRESS ON THE INCIDENCE OF OSTEOCHONDROSIS IN PIGS: SCANNING ELECTRON MICROSCOPY

1988 ◽  
Vol 68 (3) ◽  
pp. 591-602 ◽  
Author(s):  
B. WALKER ◽  
F. X. AHERNE

The object of this study was to determine the effect of mixing stress on the development of osteochondrosis, using scanning electron microscopy. Sixteen litters of eight pigs per litter were randomly assigned to one of four different treatment groups involving combinations of preweaning handling and postweaning mixing stress. Before weaning, all pigs were subjected to normal handling procedures, but one of the groups was handled with exceptional care. After-weaning treatments involved various amounts of mixing stress varying from no mixing to mixing every month. All pigs received standard starter, grower and finisher diets ad libitum (19, 16 and 14% crude protein, respectively). Eight pigs from each of the four treatment groups were randomly selected for slaughter at 3, 4, 5 and 6 mo of age. After slaughter elbow and knee joints were examined grossly and histologically by light and scanning electron microscopy for evidence of osteochondrosis. Handling and mixing stresses had no significant effect on performance in the grower or finisher periods. Mixing stress had no significant effect (P > 0.05) on the average lesion scores of cartilage from any of the sites studied. No differences were apparent under light microscopy in the morphology of humeral and femoral condylar cartilage of pigs from any of the treatment groups. Under scanning electron microscopy the surface of normal porcine condylar cartilage appeared very smooth with numerous clusters of chondrocytes evidenced by small protrusions from the surface. Pigs from the two mixed treatment groups showed extensive surface wear (osteoarthrosis) at the age of 6 mo. The results indicated that mixing stress had little effect on the incidence of osteochondrosis but may be involved in the progression of osteoarthrotic changes with advancing age. Key words: Scanning electron microscopy, swine, osteochondrosis, mixing stress

2021 ◽  
Vol 6 (1) ◽  
pp. 22
Author(s):  
Michele Runci Anastasi ◽  
Piero Cascone ◽  
Giuseppe Pio Anastasi ◽  
Giuseppe Santoro ◽  
Fabiana Nicita ◽  
...  

The extracellular matrix of the articular disc in a temporomandibular joint (TMJ) is composed mainly of collagen I and elastin. The collagen is important for resisting tensile forces, while the elastin is responsible to maintain the shape after deformation. We studied the orientation of collagen and elastin in a normal human temporomandibular joint disc by light microscopy, immunofluorescence and scanning electron microscopy. Our results demonstrated that collagen and elastin run parallel to each other in the intermediate zone with an anteroposterior orientation. From here, the orientation of two fibers groups changes into a disordered arrangement in the transition zone. Numerous elastic fibers cross with the collagen fibers, defining an interwoven knitted arrangement. The evaluation of the disc–condyle relationship shows that the medial margin of the articular disc is inserted directly at the superficial layer of the mandibular condylar cartilage. Therefore, the tensile properties of the TMJ disc are expressed in the directions corresponding to the orientation of the collagen fibers, and the complex orientation of elastin with the collagen determines the maintaining of the shape after the stresses by the joint movements. Moreover, the direct anatomical relationship between the articular disc and the mandibular condyle makes a decisive contribution to the understanding of TMJ movements.


Author(s):  
P.S. Porter ◽  
T. Aoyagi ◽  
R. Matta

Using standard techniques of scanning electron microscopy (SEM), over 1000 human hair defects have been studied. In several of the defects, the pathogenesis of the abnormality has been clarified using these techniques. It is the purpose of this paper to present several distinct morphologic abnormalities of hair and to discuss their pathogenesis as elucidated through techniques of scanning electron microscopy.


Author(s):  
P.J. Dailey

The structure of insect salivary glands has been extensively investigated during the past decade; however, none have attempted scanning electron microscopy (SEM) in ultrastructural examinations of these secretory organs. This study correlates fine structure by means of SEM cryofractography with that of thin-sectioned epoxy embedded material observed by means of transmission electron microscopy (TEM).Salivary glands of Gromphadorhina portentosa were excised and immediately submerged in cold (4°C) paraformaldehyde-glutaraldehyde fixative1 for 2 hr, washed and post-fixed in 1 per cent 0s04 in phosphosphate buffer (4°C for 2 hr). After ethanolic dehydration half of the samples were embedded in Epon 812 for TEM and half cryofractured and subsequently critical point dried for SEM. Dried specimens were mounted on aluminum stubs and coated with approximately 150 Å of gold in a cold sputtering apparatus.Figure 1 shows a cryofractured plane through a salivary acinus revealing topographical relief of secretory vesicles.


Author(s):  
Nakazo Watari ◽  
Yasuaki Hotta ◽  
Yoshio Mabuchi

It is very useful if we can observe the identical cell elements within the same sections by light microscopy (LM), transmission electron microscopy (TEM) and/or scanning electron microscopy (SEM) sequentially, because, the cell fine structure can not be indicated by LM, while the color is; on the other hand, the cell fine structure can be very easily observed by EM, although its color properties may not. However, there is one problem in that LM requires thick sections of over 1 μm, while EM needs very thin sections of under 100 nm. Recently, we have developed a new method to observe the same cell elements within the same plastic sections using both light and transmission (conventional or high-voltage) electron microscopes.In this paper, we have developed two new observation methods for the identical cell elements within the same sections, both plastic-embedded and paraffin-embedded, using light microscopy, transmission electron microscopy and/or scanning electron microscopy (Fig. 1).


Author(s):  
Ronald H. Bradley ◽  
R. S. Berk ◽  
L. D. Hazlett

The nude mouse is a hairless mutant (homozygous for the mutation nude, nu/nu), which is born lacking a thymus and possesses a severe defect in cellular immunity. Spontaneous unilateral cataractous lesions were noted (during ocular examination using a stereomicroscope at 40X) in 14 of a series of 60 animals (20%). This transmission and scanning microscopic study characterizes the morphology of this cataract and contrasts these data with normal nude mouse lens.All animals were sacrificed by an ether overdose. Eyes were enucleated and immersed in a mixed fixative (1% osmium tetroxide and 6% glutaraldehyde in Sorenson's phosphate buffer pH 7.4 at 0-4°C) for 3 hours, dehydrated in graded ethanols and embedded in Epon-Araldite for transmission microscopy. Specimens for scanning electron microscopy were fixed similarly, dehydrated in graded ethanols, then to graded changes of Freon 113 and ethanol to 100% Freon 113 and critically point dried in a Bomar critical point dryer using Freon 13 as the transition fluid.


Author(s):  
Jane A. Westfall ◽  
S. Yamataka ◽  
Paul D. Enos

Scanning electron microscopy (SEM) provides three dimensional details of external surface structures and supplements ultrastructural information provided by transmission electron microscopy (TEM). Animals composed of watery jellylike tissues such as hydras and other coelenterates have not been considered suitable for SEM studies because of the difficulty in preserving such organisms in a normal state. This study demonstrates 1) the successful use of SEM on such tissue, and 2) the unique arrangement of batteries of nematocysts within large epitheliomuscular cells on tentacles of Hydra littoralis.Whole specimens of Hydra were prepared for SEM (Figs. 1 and 2) by the fix, freeze-dry, coat technique of Small and Màrszalek. The specimens were fixed in osmium tetroxide and mercuric chloride, freeze-dried in vacuo on a prechilled 1 Kg brass block, and coated with gold-palladium. Tissues for TEM (Figs. 3 and 4) were fixed in glutaraldehyde followed by osmium tetroxide. Scanning micrographs were taken on a Cambridge Stereoscan Mark II A microscope at 10 KV and transmission micrographs were taken on an RCA EMU 3G microscope (Fig. 3) or on a Hitachi HU 11B microscope (Fig. 4).


Author(s):  
J.N. Ramsey ◽  
D.P. Cameron ◽  
F.W. Schneider

As computer components become smaller the analytical methods used to examine them and the material handling techniques must become more sensitive, and more sophisticated. We have used microbulldozing and microchiseling in conjunction with scanning electron microscopy, replica electron microscopy, and microprobe analysis for studying actual and potential problems with developmental and pilot line devices. Foreign matter, corrosion, etc, in specific locations are mechanically loosened from their substrates and removed by “extraction replication,” and examined in the appropriate instrument. The mechanical loosening is done in a controlled manner by using a microhardness tester—we use the attachment designed for our Reichert metallograph. The working tool is a pyramid shaped diamond (a Knoop indenter) which can be pushed into the specimen with a controlled pressure and in a specific location.


Author(s):  
Yasushi Kokubo ◽  
Hirotami Koike ◽  
Teruo Someya

One of the advantages of scanning electron microscopy is the capability for processing the image contrast, i.e., the image processing technique. Crewe et al were the first to apply this technique to a field emission scanning microscope and show images of individual atoms. They obtained a contrast which depended exclusively on the atomic numbers of specimen elements (Zcontrast), by displaying the images treated with the intensity ratio of elastically scattered to inelastically scattered electrons. The elastic scattering electrons were extracted by a solid detector and inelastic scattering electrons by an energy analyzer. We noted, however, that there is a possibility of the same contrast being obtained only by using an annular-type solid detector consisting of multiple concentric detector elements.


Sign in / Sign up

Export Citation Format

Share Document