scholarly journals Reproducibility of SELDI Spectra across Time and Laboratories

2011 ◽  
Vol 10 ◽  
pp. CIN.S6438 ◽  
Author(s):  
Lixia Diao ◽  
Charlotte H. Clarke ◽  
Kevin R. Coombes ◽  
Stanley R. Hamilton ◽  
Jack Roth ◽  
...  

The reproducibility of mass spectrometry (MS) data collected using surface enhanced laser desorption/ionization-time of flight (SELDI-TOF) has been questioned. This investigation was designed to test the reproducibility of SELDI data collected over time by multiple users and instruments. Five laboratories prepared arrays once every week for six weeks. Spectra were collected on separate instruments in the individual laboratories. Additionally, all of the arrays produced each week were rescanned on a single instrument in one laboratory. Lab-to-lab and array-to-array variability in alignment parameters were larger than the variability attributable to running samples during different weeks. The coefficient of variance (CV) in spectrum intensity ranged from 25% at baseline, to 80% in the matrix noise region, to about 50% during the exponential drop from the maximum matrix noise. Before normalization, the median CV of the peak heights was 72% and reduced to about 20% after normalization. Additionally, for the spectra from a common instrument, the CV ranged from 5% at baseline, to 50% in the matrix noise region, to 20% during the drop from the maximum matrix noise. Normalization reduced the variability in peak heights to about 18%. With proper processing methods, SELDI instruments produce spectra containing large numbers of reproducibly located peaks, with consistent heights.

PROTEOMICS ◽  
2004 ◽  
Vol 4 (9) ◽  
pp. 2624-2628 ◽  
Author(s):  
Dagania Barzaghi ◽  
Jenefir D. Isbister ◽  
Kimberly P. Lauer ◽  
Timothy L. Born

2007 ◽  
Vol 22 (2) ◽  
pp. 89-94 ◽  
Author(s):  
M.B. Caspersen ◽  
N.M. Sørensen ◽  
A.S. Schrohl ◽  
P. Iversen ◽  
H.J. Nielsen ◽  
...  

Early detection of colorectal cancer (CRC) improves patient survival. Plasma tissue inhibitor of metalloproteinases 1 (TIMP-1) measurements by enzyme-linked immunosorbent assay (ELISA) have been suggested as a new method for the early detection of CRC. To further investigate the nature of TIMP-1 in plasma, surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI TOF MS) was used. TIMP-1 measurements of plasma from 16 healthy donors and 14 CRC patients were performed using TIMP-1 monoclonal antibody in SELDI TOF MS and ELISA. SELDI TOF MS applying an antibody to TIMP-1 revealed that human plasma TIMP-1 has a mass of 25.1 kDa and exhibits several isoforms. Both methods showed increased plasma TIMP-1 values for cancer patients as compared to healthy individuals. The p values for the separation of the groups were 0.0019 for ELISA and <0.0001 for SELDI TOF MS. CRC did not fundamentally affect the appearance of TIMP-1 as evaluated by SELDI TOF MS.


Sign in / Sign up

Export Citation Format

Share Document