scholarly journals Diagnostic Performance of Ultrafast 3-Dimensional Ultrasound on the Small Bowel: Single Center Experience

2011 ◽  
Vol 4 ◽  
pp. CGast.S8143 ◽  
Author(s):  
Salah Elwagdy ◽  
Mokhtar Ragab Ramadan ◽  
Mohamed A. Farag ◽  
Manal Farag ◽  
Sahar Eladawy ◽  
...  

Background Increased speed and resolution of ultrasound have made it a first-line modality for the abdominal examination. During the last 5 years trans-abdominal ultrasonography has been used increasingly, for assessment of patients with small bowel (SB) diseases. Around 350 such examinations are performed annually in the diagnostic imaging department at Azhar University Hospital. Hence, the aim is to determine if the ultrafast three-dimensional ultrasound (U3D US) is potent for optimal examination of SB diseases. Patients and Methods Tap-water intake has been used to distend the SB. All patients have been examined in supine position. The U3D US data of 198 patients with SB diseases were assessed. The proximal and distal SB image quality along with the evaluation of bowel distention, motility and lesions were reported. Results Image quality was good in all examinations. Adequate demonstration of the proximal and distal SB was obtained in all of U3D US examinations. The inclusive diagnostic accuracy of U3D US was precise in 92.3%. Proximal SB was, however, less frequently involved, particularly in patients below the age of 30 years ( P = 0.050). Conclusion The diagnostic accuracy of U3D US enterography is valuable for detecting SB lesions. This modality is widely available, inexpensive and easy technique, can be used as an initial investigation in the evaluation of patients with SB disorders.

Neurosurgery ◽  
2019 ◽  
Vol 87 (4) ◽  
pp. 689-696 ◽  
Author(s):  
Serge Marbacher ◽  
Jenny C Kienzler ◽  
Itai Mendelowitsch ◽  
Donato D’Alonzo ◽  
Lukas Andereggen ◽  
...  

Abstract BACKGROUND Postoperative three-dimensional digital subtraction angiography (3D-DSA) is the gold standard in evaluating intracranial aneurysm (IA) remnants after clipping. Should intraoperative 3D-DSA image quality be equally good as postoperative 3D-DSA, it could supplant the latter as standard of care for follow-up of clipped IA. OBJECTIVE To directly compare the quality of assessment of clipped IA by intraoperative and postoperative 3D-DSA. METHODS From a prospective cohort of 221 consecutive patients who underwent craniotomy for IA treatment in a hybrid operating room, we retrospectively studied 26 patients who had both intraoperative and postoperative 3D-DSA imaging of their clipped aneurysm. Comparison of intraoperative and postoperative 3D-DSA images (blinded for review) included parameters that affected image quality and differences between the 2 periods. RESULTS In the 26 patients with 32 clipped IAs, the mean interval was 11 ± 7 mo between intraoperative and postoperative imaging 3D-DSA examinations. Reconstruction with multiple clips was used in 14 (44%) cases. Of 15 remnants, 9 (60%) were small (<2 mm). In comparing intraoperative and postoperative 3D-DSA, no discordance or discrepancy in assessment of the surgical result was noted for any clipped IA, and overall imaging quality was excellent for both modalities. Factors affecting minor differences in image quality were not identified. CONCLUSION Compared with postoperative 3D-DSA, intraoperative 3D-DSA images achieved equally high quality and effective, immediate interpretation of the surgical clipping result. With comparable imaging quality and no discordant findings, intraoperative 3D-DSA could replace postoperative 3D-DSA to become the standard of care in IA surgery.


2021 ◽  
pp. neurintsurg-2020-017252
Author(s):  
Bikei Ryu ◽  
Shinsuke Sato ◽  
Masayuki Takase ◽  
Tatsuki Mochizuki ◽  
Shogo Shima ◽  
...  

BackgroundSpinal arteriovenous shunts (SAVSs) are rare entities occurring in various areas, from the craniocervical junction to the sacral level. Recently, better understanding of SAVS angioarchitecture and elucidation of its pathogenesis have become possible with the advancement of imaging techniques. However, the utility of fusing different image modalities for SAVS diagnostics has not been determined. This study aimed to investigate whether three-dimensional-rotational angiography (3D-RA) and 3D-heavily T2-weighted volumetric MR (3D-MR) fusion imaging would improve the diagnostic accuracy for SAVSs.MethodsWe retrospectively reviewed 12 SAVSs in 12 patients. Assessment of 3D-RA and 3D-RA/3D-MR fusion images for SAVS was performed by seven blinded reviewers. The final diagnosis was performed by two interventional neuroradiologists with extensive experience, and the interobserver agreement between the reviewers and the final diagnosis was calculated using κ statistics. The comparison of the interobserver agreement between 3D-RA and 3D-RA/3D-MR fusion images was performed for the diagnosis of SAVS subtypes. We also statistically compared the image-quality gradings (on a 4-grade scale) to delineate the 3D relationship between vascular malformations and the surrounding anatomical landmarks.ResultsThe interobserver agreement for the 3D-RA/3D-MR fusion images was substantial (κ=0.7071) and higher than that for the 3D-RA images (κ=0.3534). Significantly better image quality grades were assigned to 3D-RA/3D-MR fusion images than to 3D-RA images (p<0.0001) for the evaluation of the examined 3D relationships.ConclusionThe 3D-RA/3D-MR fusion images provided better interobserver agreement of SAVS subtype diagnosis, allowing for detailed evaluation of the SAVS anatomical structures surrounding the shunt.


QJM ◽  
2020 ◽  
Vol 113 (Supplement_1) ◽  
Author(s):  
M M Alsherbiny ◽  
A A M Riad ◽  
H A Hamdoun

Abstract Introduction Various forms of female infertility were associated with congenital uterine anomalies and acquired uterine disease. In fact, the myometrium can only be indirectly imaged by X-ray hysterosalpingography but is directly seen on Ultrasonography. More recently, further advances in ultrasonography have led to three-dimensional multiplanar or volume imaging (three-dimensional ultrasonography [3DUS]) in which sonographic images are obtained from a volume of ultrasonographic data (rather than from a slice of data) the application of 3DUS to gynecologic imaging has suggested a role for transvaginal 3DUS in the assessment of uterine anomalies and endometrial lesions. Aim To evaluate the diagnostic accuracy and sensitivity of Hysteroscopy vs TV3D in the evaluation of the uterine abnormalities in infertile women before ICSI. Methodology This is a study including 60 patients were selected from the outpatient gynecological clinic, private center at Sohag government (Ibn Sina Center) in collaboration with (Ain Shams University Hospital in IVF unit) from12/2017 -8/2018. All cases files are computerized and saved in Ibn Sina Center. Results The overall result of accuracy of different modalities was 98.3% for 3D sonography and the accuracy of different modalities in detection of endometrial polyp was 93.3% for 3D sonography and 100% for hysteroscopy. The accuracy of different modalities in detection of septate uterus was 100% for 3D sonography and hysteroscopy. The accuracy of different modalities in detection of intrauterine adhesions was 100% for 100% for 3D and hysteroscopy. Conclusion Hysteroscopy is the gold standard diagnostic & therapeutic tool for uterine anomalies (bicornuate, septate, arcuate, polyp), However 3D ultrasonography is diagnostic tool only but superior to hysteroscopy in certain lesions e.g. (subserous and intramural fibroid). Recommendation we recommend 3D to become soon as the diagnostic procedure of choice in assessment of suspected uterine lesions. Furthermore, we recommend that 3D US, if available, to be performed routinely for all cases of uterine cavity anomalies and prior to corrective uterine surgery.


Author(s):  
Robert Glaeser ◽  
Thomas Bauer ◽  
David Grano

In transmission electron microscopy, the 3-dimensional structure of an object is usually obtained in one of two ways. For objects which can be included in one specimen, as for example with elements included in freeze- dried whole mounts and examined with a high voltage microscope, stereo pairs can be obtained which exhibit the 3-D structure of the element. For objects which can not be included in one specimen, the 3-D shape is obtained by reconstruction from serial sections. However, without stereo imagery, only detail which remains constant within the thickness of the section can be used in the reconstruction; consequently, the choice is between a low resolution reconstruction using a few thick sections and a better resolution reconstruction using many thin sections, generally a tedious chore. This paper describes an approach to 3-D reconstruction which uses stereo images of serial thick sections to reconstruct an object including detail which changes within the depth of an individual thick section.


Author(s):  
Neil Rowlands ◽  
Jeff Price ◽  
Michael Kersker ◽  
Seichi Suzuki ◽  
Steve Young ◽  
...  

Three-dimensional (3D) microstructure visualization on the electron microscope requires that the sample be tilted to different positions to collect a series of projections. This tilting should be performed rapidly for on-line stereo viewing and precisely for off-line tomographic reconstruction. Usually a projection series is collected using mechanical stage tilt alone. The stereo pairs must be viewed off-line and the 60 to 120 tomographic projections must be aligned with fiduciary markers or digital correlation methods. The delay in viewing stereo pairs and the alignment problems in tomographic reconstruction could be eliminated or improved by tilting the beam if such tilt could be accomplished without image translation.A microscope capable of beam tilt with simultaneous image shift to eliminate tilt-induced translation has been investigated for 3D imaging of thick (1 μm) biologic specimens. By tilting the beam above and through the specimen and bringing it back below the specimen, a brightfield image with a projection angle corresponding to the beam tilt angle can be recorded (Fig. 1a).


Molecules ◽  
2021 ◽  
Vol 26 (13) ◽  
pp. 3887
Author(s):  
Watcharapong Pudkon ◽  
Chavee Laomeephol ◽  
Siriporn Damrongsakkul ◽  
Sorada Kanokpanont ◽  
Juthamas Ratanavaraporn

Three-dimensional (3D) printing is regarded as a critical technology in material engineering for biomedical applications. From a previous report, silk fibroin (SF) has been used as a biomaterial for tissue engineering due to its biocompatibility, biodegradability, non-toxicity and robust mechanical properties which provide a potential as material for 3D-printing. In this study, SF-based hydrogels with different formulations and SF concentrations (1–3%wt) were prepared by natural gelation (SF/self-gelled), sodium tetradecyl sulfate-induced (SF/STS) and dimyristoyl glycerophosphorylglycerol-induced (SF/DMPG). From the results, 2%wt SF-based (2SF) hydrogels showed suitable properties for extrusion, such as storage modulus, shear-thinning behavior and degree of structure recovery. The 4-layer box structure of all 2SF-based hydrogel formulations could be printed without structural collapse. In addition, the mechanical stability of printed structures after three-step post-treatment was investigated. The printed structure of 2SF/STS and 2SF/DMPG hydrogels exhibited high stability with high degree of structure recovery as 70.4% and 53.7%, respectively, compared to 2SF/self-gelled construct as 38.9%. The 2SF/STS and 2SF/DMPG hydrogels showed a great potential to use as material for 3D-printing due to its rheological properties, printability and structure stability.


Author(s):  
Fabio Barra ◽  
Franco Alessandri ◽  
Carolina Scala ◽  
Simone Ferrero

<b><i>Objective:</i></b> The use of three-dimensional (3D) transvaginal ultrasonography (TVS) has been investigated for the diagnosis of deep endometriosis (DE). This study aimed to evaluate if 3D reconstructions improve the performance of TVS) in assessing the presence and characteristics of bladder endometriosis (BE). <b><i>Design:</i></b> This was a single-center comparative diagnostic accuracy study. <b><i>Participants/Materials, Setting, Methods:</i></b> Patients referred to our institution (Piazza della Vittoria 14 Srl, Genova, Italy) with clinical suspicion of DE were included. In case of surgery, women underwent systematic preoperative ultrasonographic imaging; an experienced sonographer performed a conventional TVS; another experienced sonographer, blinded to results of the previous exam, performed TVS, with the addition of 3D modality. The presence and characteristics of BE nodules were described in accord with International DE Analysis group consensus. Ultrasound data were compared with surgical and histological results. <b><i>Results:</i></b> Overall, BE was intraoperatively found in 34 out of 194 women who underwent surgery for DE (17.5%; 95% confidence interval: 12.8–23.5%). TVS without and with 3D reconstructions were able to detect endometriotic BE in 82.2% (<i>n</i> = 28/34) and 85.3% (<i>n</i> = 29/34) of the cases (<i>p</i> = 0.125). Both the exams similarly estimated the largest diameter of BE (<i>p</i> = 0.652) and the distance between the endometriotic nodule and the closest ureteral meatus (<i>p</i> = 0.341). However, TVS with 3D reconstructions was more precise in estimating the volume of BE (<i>p</i> = 0.031). In one case (2.9%), TVS without and with 3D reconstructions detected the infiltration of the intramural ureter, which was confirmed at surgery and required laparoscopic ureterovesical reimplantation. <b><i>Limitations:</i></b> The extensive experience of the gynecologists performing the ultrasonographic scans, the lack of prestudy power analysis, and the population selected, which may have been influenced by the position of the institution as a referral center specialized in the treatment of severe endometriosis, are limitations of the current study. <b><i>Conclusion:</i></b> Our results demonstrated the high accuracy of ultrasound for diagnosing BE. The addition of 3D reconstructions does not improve the performance of TVS in diagnosing the presence and characteristics of BE. However, the volume of BE may be more precisely assessed by 3D ultrasound.


Author(s):  
So Young Joo ◽  
Seung Yeol Lee ◽  
Yoon Soo Cho ◽  
Sangho Yi ◽  
Cheong Hoon Seo

Abstract Hands are the part of the body that are most commonly involved in burns, and the main complications are finger joint contractures and nerve injuries. Hypertrophic scarring cannot be avoided despite early management of acute hand burn injuries, and some patients may need application of an exoskeleton robot to restore hand function. To do this, it is essential to individualize the customization of the robot for each patient. Three-dimensional (3D) technology, which is widely used in the field of implants, anatomical models, and tissue fabrication, makes this goal achievable. Therefore, this report is a study on the usefulness of an exoskeleton robot using 3D technology for patients who lost bilateral hand function due to burn injury. Our subject was a 45-year-old man with upper limb dysfunction of 560 days after a flame and chemical burn injury, with resultant impairment of manual physical abilities. After wearing an exoskeleton robot made using 3D printing technology, he could handle objects effectively and satisfactorily. This innovative approach provided considerable advantages in terms of customization of size and reduction in manufacturing time and costs, thereby showing great potential for use in patients with hand dysfunction after burn injury.


Author(s):  
David T. McGreevy ◽  
Mitra Sadeghi ◽  
Kristofer F. Nilsson ◽  
Tal M. Hörer

Abstract Background Hemodynamic instability due to torso hemorrhage can be managed with the assistance of resuscitative endovascular balloon occlusion of the aorta (REBOA). This is a report of a single-center experience using the ER-REBOA™ catheter for traumatic and non-traumatic cases as an adjunct to hemorrhage control and as part of the EndoVascular resuscitation and Trauma Management (EVTM) concept. The objective of this report is to describe the clinical usage, technical success, results, complications and outcomes of the ER-REBOA™ catheter at Örebro University hospital, a middle-sized university hospital in Europe. Methods Data concerning patients receiving the ER-REBOA™ catheter for any type of hemorrhagic shock and hemodynamic instability at Örebro University hospital in Sweden were collected prospectively from October 2015 to May 2020. Results A total of 24 patients received the ER-REBOA™ catheter (with the intention to use) for traumatic and non-traumatic hemodynamic control; it was used in 22 patients. REBOA was performed or supervised by vascular surgeons using 7–8 Fr sheaths with an anatomic landmark or ultrasound guidance. Systolic blood pressure (SBP) increased significantly from 50 mmHg (0–63) to 95 mmHg (70–121) post REBOA. In this cohort, distal embolization and balloon rupture due to atherosclerosis were reported in one patient and two patients developed renal failure. There were no cases of balloon migration. Overall 30-day survival was 59%, with 45% for trauma patients and 73% for non-traumatic patients. Responders to REBOA had a significantly lower rate of mortality at both 24 h and 30 days. Conclusions Our clinical data and experience show that the ER-REBOA™ catheter can be used for control of hemodynamic instability and to significantly increase SBP in both traumatic and non-traumatic cases, with relatively few complications. Responders to REBOA have a significantly lower rate of mortality.