scholarly journals Urinary 1-Hydroxypyrene as a Biomarker to Carcinogenic Polycyclic Aromatic Hydrocarbon Exposure

2012 ◽  
Vol 4 ◽  
pp. BIC.S10065 ◽  
Author(s):  
Clinton Ifegwu ◽  
Kayode Osunjaye ◽  
Folasade Fashogbon ◽  
Kolawole Oke ◽  
Afolabi Adeniyi ◽  
...  

In order to capture the extent of exposure to polycyclic aromatic hydrocarbons (PAHs), various biomarkers have been employed. The biomarkers employed for PAHs include PAHs genetoxic end points in lymphocytes, urinary metabolites, PAH-DNA adducts, and PAH-Protein adducts. Of these, excretory 1-hydroxypyene, a metabolite of pyrene, has been used extensively as a biological monitoring indicator of exposure to PAHs. This study attempts to assess the level of this biomarker in the body fluid of 68 exposed subjects using high performance liquid chromatography HPLC. The subjects screened included auto mechanics, drivers, and fuel attendants. 1-hydroxypyrene was extracted from the urine of the subjects using solid phase extraction method. The HPLC analysis was done in isocratic mode using water:methanol (12:88 v/v) mobile phase. The stationary phase was XBridge C18 (150 × 4.6 mm) 5 μm column. The wavelength was 250 nm at a flow rate of 1.2 mL/min. The oven temperature was 30 °C and the injection volume was 20 μL. The run time was 3 minutes. The level of urinary 1-hydroxypyrene detected varied for the different categories of occupation studied. About 27% of sampled fuel attendants and 22% of auto mechanics had detectable 1-hydroxypyrene in their urine samples. There was no detectable 1-hydroxypyene in the urine samples of commercial drivers or in the urine samples of students used as controls. The results of this study showed that fuel attendants and auto mechanics have significant exposures to PAHs. So far, there is no established benchmark for level of PAHs in urine, but our findings indicate the possibility of future cancer cases in this population as a result of their occupational exposure. The study was not able to link the level of 1-hydroxypyene with the smoking habits of the subjects.

Molecules ◽  
2019 ◽  
Vol 24 (22) ◽  
pp. 4186 ◽  
Author(s):  
Yuanman Liu ◽  
Ziling Li ◽  
Ziyang Zhang ◽  
Tengwen Zhao ◽  
Manman Wang ◽  
...  

A diatomite supported graphene oxide composite (GO@Dt–NH2) was fabricated and explored as a solid-phase extraction adsorbent coupled with high performance liquid chromatography to determine the trace hydroxyl polycyclic aromatic hydrocarbons (2-hydroxy-naphthalene, 2-hydroxy-fluorene, 1-hydroxy-phenanthrene, and 1-hydroxy-pyrene) in urine samples. The fabricated composites were characterized by X-ray powder diffractometry and scanning electron microscopy. GO@Dt–NH2 offered enhanced adsorption affinity towards the analytes compared with the bare diatomite. The amount of graphene oxide and the factors affecting solid-phase extraction were investigated in detail. Under the optimized conditions, the method gave good linearity (0.30–200 ng/mL) and a low detection limit (0.10–0.15 ng/mL) for the hydroxyl polycyclic aromatic hydrocarbons. The average recovery for spiked urine samples with three levels ranged from 90.6% to 100%. The intra-day and inter-day relative standard deviations were in the range of 1.8–6.4% and 2.7–11.8%, respectively. Besides, the GO@Dt–NH2 provided enrichment factors of 18–20 and superior purification ability. The developed method was successfully applied to the determination of hydroxyl polycyclic aromatic hydrocarbons in urine samples from smoking volunteers.


Molecules ◽  
2018 ◽  
Vol 23 (11) ◽  
pp. 2869 ◽  
Author(s):  
Iván Taima-Mancera ◽  
Priscilla Rocío-Bautista ◽  
Jorge Pasán ◽  
Juan Ayala ◽  
Catalina Ruiz-Pérez ◽  
...  

Four metal-organic frameworks (MOFs), specifically UiO-66, UiO-66-NH2, UiO-66-NO2, and MIL-53(Al), were synthesized, characterized, and used as sorbents in a dispersive micro-solid phase extraction (D-µSPE) method for the determination of nine pollutants of different nature, including drugs, phenols, polycyclic aromatic hydrocarbons, and personal care products in environmental waters. The D-µSPE method, using these MOFs as sorbents and in combination with high-performance liquid chromatography (HPLC) and diode-array detection (DAD), was optimized. The optimization study pointed out to UiO-66-NO2 as the best MOF to use in the multi-component determination. Furthermore, the utilization of isoreticular MOFs based on UiO-66 with the same topology but different functional groups, and MIL-53(Al) to compare with, allowed us for the first time to evaluate the influence of such functionalization of the ligand with regards to the efficiency of the D-µSPE-HPLC-DAD method. Optimum conditions included: 20 mg of UiO-66-NO2 MOF in 20 mL of the aqueous sample, 3 min of agitation by vortex and 5 min of centrifugation, followed by the use of only 500 µL of acetonitrile as desorption solvent (once the MOF containing analytes was separated), 5 min of vortex and 5 min of centrifugation. The validation of the D-µSPE-HPLC-DAD method showed limits of detection down to 1.5 ng·L−1, average relative recoveries of 107% for a spiked level of 1.50 µg·L−1, and inter-day precision values with relative standard deviations lower than 14%, for the group of pollutants considered.


Sign in / Sign up

Export Citation Format

Share Document