scholarly journals Effect of acid etching on the micro-shear bond strength of resin composite–calcium silicate interface evaluated over different time intervals of bond aging

2018 ◽  
Vol 21 (2) ◽  
pp. 194 ◽  
Author(s):  
Sangeeta Talwar ◽  
Neha Sultana ◽  
RuchikaRoongta Nawal ◽  
Sarika Chaudhry ◽  
Malavika Sivakumar
2019 ◽  
Vol 48 ◽  
Author(s):  
Cedirlei Gomes da Silveira ANDRADE ◽  
Diego Patrik Alves CARNEIRO ◽  
Mariana NABARRETTE ◽  
Américo Bortolazzo CORRER ◽  
Heloisa Cristina VALDRIGHI

Abstract Introduction Surface treatment prior to bonding ceramic brackets with hydrofluoric acid is indicated because of its ability to promote morphological changes necessary for adhesion. Objective To evaluate the shear bond strength (RUC) of metal brackets bonded to the feldspar ceramic surface under the action of hydrofluoric acid (AF), in different concentrations (5% and 10%) and different application times (30 and 60 seconds). Material and method Four nickel-chrome metal blocks that received an application of feldspathic ceramic were used, to which 80 metal brackets (Abzil/3M) were bonded and divided into 4 Groups (n=20) according to the acid etching procedure. The blocks were etched with 5% hydrofluoric acid for 30 and 60 seconds (AF5/30 and AF5/60, respectively) and 10% hydrofluoric acid for 30 and 60 seconds (AF10/30, AF10/60, respectively). The resin composite used was Transbond XT (3M) and the presence of a glazer was maintained on the ceramic surface. The specimens were placed on a Universal test machine Instron 4411 (Instron Corp, USA) to which a chisel was adapted to perform the shear test at a speed of 1mm/min. The data were submitted to the analysis of variance (ANOVA) and the Adhesive Remnant Index was evaluated. Result In the time interval of 30 seconds, there was no significant difference for the 5% and 10% hydrofluoric acid concentrations. In the 60-second time interval, the 10% concentration showed significantly higher shear bond strength values (p<0.05). The ARI showed predominance of scores 1 and 2. Conclusion It was concluded that 10% hydrofluoric acid showed higher shear bond strength values in 60 seconds of etching, while 5% hydrofluoric acid showed no significant difference between the etching times.


2016 ◽  
Vol 35 (6) ◽  
pp. 881-887 ◽  
Author(s):  
Hanan ALZRAIKAT ◽  
Nessrin A. TAHA ◽  
Deema QASRAWI ◽  
Michael F. BURROW

2021 ◽  
Vol 12 (5) ◽  
pp. 6863-6872

In this experimental study, the effects of Er,Cr:YSGG laser on the shear bond strength (SBS) of brackets bonded to two ceramic surfaces (Feldspathic and IPS Empress II) were compared to hydrofluoric (HF) acid etching. 60 ceramic discs were prepared, including two groups: Feldspathic and IPS Empress II surfaces. In each group, the following subgroups were prepared: 2W Er,Cr:YSGG laser, 2.5W Er,Cr:YSGG laser, and HF acid-etching. Ceramic primer and adhesive resin composite were applied and then light-cured to bond the ceramic cylinders to brackets. The samples were stored in distilled water for 24h and then, thermocycled. SBS testing was performed with a universal testing machine. Two-way ANOVA was used to compare SBS among subgroups (P<0.05). The highest SBS was seen in feldspathic surfaces with HF preparation (14.61±3.11MPa). There was a significant difference in SBS between different surface treatments except between the laser groups of IPS Empress II. Also, feldspathic surfaces had significantly higher SBS than IPS Empress II in all groups except HF. Conventional surface treatment provides much stronger adhesion than laser regardless of the ceramic type. Er,Cr:YSGG laser is effective on the SBS of the feldspathic ceramics, but not in IPS Empress II ceramics. So, laser treatment can be recommended as a favorable setting for treating feldspathic surfaces.


2008 ◽  
Vol 27 (4) ◽  
pp. 515-522 ◽  
Author(s):  
Sayaka HORI ◽  
Hiroyuki MINAMI ◽  
Yoshito MINESAKI ◽  
Hideo MATSUMURA ◽  
Takuo TANAKA

2020 ◽  
Vol 8 (02) ◽  
pp. 49-54
Author(s):  
Salil Mehra ◽  
Ashu K. Gupta ◽  
Bhanu Pratap Singh ◽  
Mandeep Kaur ◽  
Ashwath Kumar

Abstract Introduction The aim of the current study was to evaluate shear bond strength of resin composite bonded to Theracal LC, Biodentine, and resin-modified glass ionomer cement (RMGIC) using universal adhesive and mode of fracture. Materials and Methods A total of 50 caries-free maxillary and mandibular molars extracted were taken; occlusal cavities were prepared, mounted in acrylic blocks, and divided into five groups based on the liner used. Group 1: Biodentine liner placed into the cavity and bonding agent and resin composite applied after 12 minutes. Group 2: Biodentine liner placed into the cavity and bonding agent and resin composite applied after 14 days. Group 3: RMGIC liner placed into the cavity and bonding agent and resin composite applied immediately. Group 4: RMGIC liner placed into the cavity and bonding agent and resin composite applied after 7 days. Group 5: Theracal LC liner placed into the cavity and bonding agent and resin composite applied immediately. Each sample was bonded to resin composite using universal adhesive. Shear bond strength analysis was performed at a cross-head speed of 0.1 mm/min. Statistical Analysis  Statistical analysis was performed with one-way analysis of variance and posthoc Bonferroni test using SPSS version 22.0. Results and Conclusion Biodentine liner when bonded immediately to resin composite showed minimum shear bond strength. RMGIC when bonded to resin composite after 7 days showed maximum shear bond strength. Mode of fracture was predominantly cohesive in groups having Biodentine and Theracal LC as liner.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Ahmed Mohammed Hassan ◽  
Ahmed Ali Goda ◽  
Kusai Baroudi

Objective. The aim of this study was to evaluate the effect of different disinfectant agents on bond strength of two types of resin composite materials.Methods. A total of 80 sound posterior teeth were used. They were divided into four groups(n=20)according to the dentin surface pretreatment (no treatment, chlorhexidine gluconate 2%, sodium hypochlorite 4%, and EDTA 19%). Each group was divided into two subgroups according to the type of adhesive (prime and bond 2.1 and Adper easy one). Each subgroup was further divided into two subgroups according to the type of resin composite (TPH spectrum and Tetric EvoCeram). Shear bond strength between dentin and resin composite was measured using Universal Testing Machine. Data collected were statistically analyzed byt-test and one-way ANOVA followed by Tukey’spost hoctest.Results. It was found that dentin treated with EDTA recorded the highest shear bond strength values followed by sodium hypochlorite and then chlorhexidine groups while the control group showed the lowest shear bond strength.Conclusions. The surface treatment of dentin before bonding application has a great effect on shear bond strength between resin composite and dentin surface.


2015 ◽  
Vol 20 (4) ◽  
pp. 51-56 ◽  
Author(s):  
João Paulo Fragomeni Stella ◽  
Andrea Becker Oliveira ◽  
Lincoln Issamu Nojima ◽  
Mariana Marquezan

OBJECTIVE: To assess four different chemical surface conditioning methods for ceramic material before bracket bonding, and their impact on shear bond strength and surface integrity at debonding.METHODS: Four experimental groups (n = 13) were set up according to the ceramic conditioning method: G1 = 37% phosphoric acid etching followed by silane application; G2 = 37% liquid phosphoric acid etching, no rinsing, followed by silane application; G3 = 10% hydrofluoric acid etching alone; and G4 = 10% hydrofluoric acid etching followed by silane application. After surface conditioning, metal brackets were bonded to porcelain by means of the Transbond XP system (3M Unitek). Samples were submitted to shear bond strength tests in a universal testing machine and the surfaces were later assessed with a microscope under 8 X magnification. ANOVA/Tukey tests were performed to establish the difference between groups (α= 5%).RESULTS: The highest shear bond strength values were found in groups G3 and G4 (22.01 ± 2.15 MPa and 22.83 ± 3.32 Mpa, respectively), followed by G1 (16.42 ± 3.61 MPa) and G2 (9.29 ± 1.95 MPa). As regards surface evaluation after bracket debonding, the use of liquid phosphoric acid followed by silane application (G2) produced the least damage to porcelain. When hydrofluoric acid and silane were applied, the risk of ceramic fracture increased.CONCLUSIONS: Acceptable levels of bond strength for clinical use were reached by all methods tested; however, liquid phosphoric acid etching followed by silane application (G2) resulted in the least damage to the ceramic surface.


Materials ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 2216 ◽  
Author(s):  
Paulo Palma ◽  
Joana Marques ◽  
Rui Falacho ◽  
Alexandra Vinagre ◽  
João Santos ◽  
...  

The purpose of the present study was to assess the proper time to perform a restoration (immediately or delayed) after placement of two calcium silicate-based cements (CSCs) and to test the performance of two different restorative protocols regarding shear bond strength (SBS). Seventy-five acrylic blocks were randomly divided into five groups (n = 15). Specimens were filled with either ProRoot MTA (Dentsply Tulsa Dental) or Biodentine (Septodont). The restoration was performed at an immediate (12 min) or delayed (seven days) timeframe, using a resin-based flowable composite (SDR) (bonded to the CSC using a universal bonding system) or glass ionomer cement (GIC) as restorative materials. SBS was measured using a universal testing machine. Fractured surfaces were evaluated, and the pattern was registered. Statistical analysis was performed using the Dunn–Sidak post hoc test (P < 0.05). Biodentine/immediate SDR showed the highest mean SBS value (4.44 MPa), with statistically significant differences when compared to mineral trioxide aggregate (MTA)/GIC (1.14 MPa) and MTA/immediate SDR (1.33 MPa). MTA/GIC and MTA/immediate SDR did not present significant differences regarding SBS. No statistical differences were verified concerning mean SBS between both CSCs within the 7 day groups. MTA/delayed SDR (3.86 MPa) presented statistical differences compared to MTA/immediate SDR, whereas no differences were observed regarding Biodentine performance (Biodentine/immediate SDR and Biodentine/delayed SDR (3.09 MPa)). Bonding procedures directly on top of MTA might be preferably performed at a delayed timeframe, whereas Biodentine might allow for immediate restoration.


Sign in / Sign up

Export Citation Format

Share Document