scholarly journals High frequency audiometry in tinnitus patients with normal hearing in conventional audiometry

2018 ◽  
Vol 34 (4) ◽  
pp. 308
Author(s):  
DoaaM Elmoazen ◽  
HeshamS Kozou ◽  
AlaaA Mohamed
2021 ◽  
pp. 1-10
Author(s):  
Ward R. Drennan

<b><i>Introduction:</i></b> Normal-hearing people often have complaints about the ability to recognize speech in noise. Such disabilities are not typically assessed with conventional audiometry. Suprathreshold temporal deficits might contribute to reduced word recognition in noise as well as reduced temporally based binaural release of masking for speech. Extended high-frequency audibility (&#x3e;8 kHz) has also been shown to contribute to speech perception in noise. The primary aim of this study was to compare conventional audiometric measures with measures that could reveal subclinical deficits. <b><i>Methods:</i></b> Conventional and extended high-frequency audiometry was done with 119 normal-hearing people ranging in age from 18 to 72. The ability to recognize words in noise was evaluated with and without differences in temporally based spatial cues. A low-uncertainty, closed-set word recognition task was used to limit cognitive influences. <b><i>Results:</i></b> In normal-hearing listeners, word recognition in noise ability decreases significantly with increasing pure-tone average (PTA). On average, signal-to-noise ratios worsened by 5.7 and 6.0 dB over the normal range, for the diotic and dichotic conditions, respectively. When controlling for age, a significant relationship remained in the diotic condition. Measurement error was estimated at 1.4 and 1.6 dB for the diotic and dichotic conditions, respectively. Controlling for both PTA and age, EHF-PTAs showed significant partial correlations with SNR50 in both conditions (<i>ρ</i> = 0.30 and 0.23). Temporally based binaural release of masking worsened with age by 1.94 dB from 18 to 72 years old but showed no significant relationship with either PTA. <b><i>Conclusions:</i></b> All three assessments in this study demonstrated hearing problems independently of those observed in conventional audiometry. Considerable degradations in word recognition in noise abilities were observed as PTAs increased within the normal range. The use of an efficient words-in-noise measure might help identify functional hearing problems for individuals that are traditionally normal hearing. Extended audiometry provided additional predictive power for word recognition in noise independent of both the PTA and age. Temporally based binaural release of masking for word recognition decreased with age independent of PTAs within the normal range, indicating multiple mechanisms of age-related decline with potential clinical impact.


2015 ◽  
Vol 2015 ◽  
pp. 1-5 ◽  
Author(s):  
Veronika Vielsmeier ◽  
Astrid Lehner ◽  
Jürgen Strutz ◽  
Thomas Steffens ◽  
Peter M. Kreuzer ◽  
...  

Objective. The majority of tinnitus patients suffer from hearing loss. But a subgroup of tinnitus patients show normal hearing thresholds in the conventional pure-tone audiometry (125 Hz–8 kHz). Here we explored whether the results of the high frequency audiometry (>8 kHz) provide relevant additional information in tinnitus patients with normal conventional audiometry by comparing those with normal and pathological high frequency audiometry with respect to their demographic and clinical characteristics.Subjects and Methods. From the database of the Tinnitus Clinic at Regensburg we identified 75 patients with normal hearing thresholds in the conventional pure-tone audiometry. We contrasted these patients with normal and pathological high-frequency audiogram and compared them with respect to gender, age, tinnitus severity, pitch, laterality and duration, comorbid symptoms and triggers for tinnitus onset.Results. Patients with pathological high frequency audiometry were significantly older and had higher scores on the tinnitus questionnaires in comparison to patients with normal high frequency audiometry. Furthermore, there was an association of high frequency audiometry with the laterality of tinnitus.Conclusion. In tinnitus patients with normal pure-tone audiometry the high frequency audiometry provides useful additional information. The association between tinnitus laterality and asymmetry of the high frequency audiometry suggests a potential causal role for the high frequency hearing loss in tinnitus etiopathogenesis.


2016 ◽  
Vol 137 (2) ◽  
pp. 161-166 ◽  
Author(s):  
Mar Lasso de la Vega ◽  
Ithzel María Villarreal ◽  
Julio López Moya ◽  
José Ramón García-Berrocal

2019 ◽  
Vol 28 (1S) ◽  
pp. 209-224 ◽  
Author(s):  
Julia Campbell ◽  
Alison LaBrec ◽  
Connor Bean ◽  
Mashhood Nielsen ◽  
Won So

2007 ◽  
Vol 25 (10) ◽  
pp. 1190-1195 ◽  
Author(s):  
Kristin R. Knight ◽  
Dale F. Kraemer ◽  
Christiane Winter ◽  
Edward A. Neuwelt

Purpose The objective is to describe progressive changes in hearing and cochlear function in children and adolescents treated with platinum-based chemotherapy and to begin preliminary evaluation of the feasibility of extended high-frequency audiometry and distortion product otoacoustic emissions for ototoxicity monitoring in children. Patients and Methods Baseline and serial measurement of conventional pure-tone audiometry (0.5 to 8 kHz) and evoked distortion product otoacoustic emissions (DPOAEs) were conducted for 32 patients age 8 months to 20 years who were treated with cisplatin and/or carboplatin chemotherapy. Seventeen children also had baseline and serial measurement of extended high-frequency (EHF) audiometry (9 to 16 kHz). Audiologic data were analyzed to determine the incidence of ototoxicity using the American Speech-Language-Hearing Association criteria, and the relationships between the different measures of ototoxicity. Results Of the 32 children, 20 (62.5%) acquired bilateral ototoxicity in the conventional frequency range during chemotherapy treatment, and 26 (81.3%) had bilateral decreases in DPOAE amplitudes and dynamic range. Of the 17 children with EHF audiometry results, 16 (94.1%) had bilateral ototoxicity in the EHF range. Pilot data suggest that EHF thresholds and DPOAEs show ototoxic changes before hearing loss is detected by conventional audiometry. Conclusion EHF audiometry and DPOAEs have the potential to reveal earlier changes in auditory function than conventional frequency audiometry during platinum chemotherapy in children.


1985 ◽  
Vol 24 (6) ◽  
pp. 387-395 ◽  
Author(s):  
W. A. Dreschler ◽  
R.J.A.M. v.d. Hulst ◽  
R. A. Tange ◽  
N. A. M. Urbanus

Sign in / Sign up

Export Citation Format

Share Document