scholarly journals Cross-sectional, observational study of anterior segment parameters using anterior segment optical coherence tomography in North Indian Population

2017 ◽  
Vol 16 (3) ◽  
pp. 131
Author(s):  
LatikaKhatri Dalal ◽  
Renu Dhasmana ◽  
Amit Maitreya
2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Riham S. H. M. Allam ◽  
Rania A. Ahmed

Purpose. To study features of the lower punctum in normal subjects using spectral domain anterior segment optical coherence tomography (SD AS-OCT).Methods. Observational cross-sectional study that included 147 punctae (76 subjects). Punctae were evaluated clinically for appearance, position, and size. AS-OCT was used to evaluate the punctal shape, contents, and junction with the vertical canaliculus. Inner and outer diameters as well as depth were measured.Results. 24 males and 52 females (mean age44±14.35 y) were included. Lower punctum was perceived by OCT to be an area with an outer diameter (mean412.16±163 μm), inner diameter (mean233.67±138.73 μm), and depth (mean251.7±126.58 μm). The OCT measured outer punctum diameter was significantly less than that measured clinically (P: 0.000). Seven major shapes were identified. The junction with the vertical canaliculus was detectable in 44%. Fluid was detected in 34%, one of which had an air bubble; however, 63% of punctae showed no contents and 4% had debris.Conclusions. AS-OCT can be a useful tool in understanding the anatomy of the punctum and distal lacrimal system as well as tear drainage physiology. Measuring the punctum size may play a role in plugs fitting.


2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Naresh Babu Kannan ◽  
Sagnik Sen ◽  
Prithviraj Udaya ◽  
Obuli Ramachandran ◽  
Kim Ramasamy

Purpose. To study the clinicodemographic profile of dome-shaped maculopathy (DSM) eyes in the Indian population and characterization using spectral-domain optical coherence tomography (SD-OCT). Methods. This observational cross-sectional study included 25 eyes of 14 patients diagnosed with DSM. All eyes underwent SD-OCT for characterization of the dome profile and also to measure central macular thickness (CMT), subfoveal choroidal thickness (SFCT), and dome height (DH) and to detect the presence of subretinal fluid (SRF). Results. The mean age of patients was 48.36 ± 14.23 years (range, 28–65 years). Eleven patients had bilateral involvement. Mean axial length of all eyes was 24.25 ± 1.95 mm and mean spherical equivalent −4.23 ± 3.79 DS. Overall, 11/25 eyes (44%) had round domes, 9/25 eyes (36%) had horizontal domes, and 5/25 eyes (20%) had vertical domes, with a mean dome height at fovea of 500.54 ± 291.58 µm. Vertical domes had higher DH compared to horizontal or combined domes p = 0.02 . Six eyes (6/25, 24%) showed the presence of SRF; 60% of vertical domes had SRF, and 22.2% of horizontal domes had SRF. The eyes having SRF had significantly higher CMT p = 0.017 and DH p = 0.001 , especially in horizontal domes p = 0.023 . The eyes with thicker SFCT tended to have higher DH and poorer visual acuity. Conclusion. Indian DSM eyes may have relatively lesser amounts of myopia. Choroidal thickening may play a role in development of DSM and may also be related to development of subretinal fluid in such eyes.


2020 ◽  
pp. 112067212097119
Author(s):  
Sreeram Jayaraj ◽  
Anupam Singh ◽  
Ajai Agrawal ◽  
Rakesh Panyala ◽  
Ramanuj Samanta ◽  
...  

Introduction: To study the accuracy of anterior segment optical coherence tomography (AS-OCT) function of Cirrus HD-OCT 500 (Carl Zeiss Meditec, Dublin, CA) in calculating the insertion of rectus muscles from the limbus in patients undergoing primary squint surgery. Methodology: A prospective, double-masked, observational study was conducted on 128 muscles of 46 patients with strabismus who were planned for strabismus surgery between January 2019 and December 2019. Insertion distance from limbus was measured using AS-OCT function of Cirrus HD-OCT 500 preoperatively. Intraoperative measurements were taken using Castroviejo caliper. A Bland-Altman analysis was performed to determine the agreement between the readings. Results: A total of 128 muscles were successfully imaged and evaluated, including 13 superior recti (10.15%), 23 inferior recti (17.96%), 35 medial recti (27.34%) and 57 lateral recti (44.53%). 124 muscles (96.9%) were within 1mm difference, which was considered clinically acceptable. Bland-Altman plots showed the level of agreement between the two methods was good. Conclusion: Anterior segment scan function of Cirrus HD-OCT 500 is an accurate method to detect the insertion of extraocular recti muscles in patients of primary strabismus surgery.


2020 ◽  
pp. bjophthalmol-2019-315445
Author(s):  
Alexei N Kulikov ◽  
Dmitrii S Maltsev ◽  
Alina A Kazak ◽  
Maria A Burnasheva

PurposeTo study the correlation between intraocular pressure (IOP) reduction and the number of hyper-reflective particles appearing in the anterior chamber following selective laser trabeculoplasty (SLT).Material and methodsIn this prospective interventional study, we included primary open-angle glaucoma patients. All participants received a standardised SLT session, which consisted of 100 pulses of 0.9 mJ over 360°. Anterior segment optical coherence tomography (4×4 mm volume scan, 101 horizontal cross-sectional scans) and applanation tonometry were performed before SLT and 15 min, 1 day, 1 week, 1 month and 3 months after. Particles were counted on cross-sectional scans using a standardised algorithm.ResultsIn this study, we included 25 patients (25 eyes), 14 males and 11 females, with a mean age of 68.9±10.5 and baseline IOP of 21.4±4.5 mm Hg. IOP at month 1 and month 3 after SLT was 18.0±4.0 and 17.4±3.3 mm Hg, respectively. The mean number of anterior chamber particles before and 15 min after SLT was 0.62±0.2 and 7.1±2.0 particles/mm2, respectively (p=0.036). There was a statistically significant correlation between the mean number of anterior chamber particles 15 min after SLT and IOP reduction at 1 month (r=0.62, p=0.03) and 3 months (r=0.71, p=0.01).ConclusionThe number of the anterior chamber particles graded using anterior segment optical coherence tomography after the procedure correlates with the IOP-lowering effect of SLT.


Sign in / Sign up

Export Citation Format

Share Document