scholarly journals Deep sedation versus minimal sedation during endobronchial ultrasound transbronchial needle aspiration

2018 ◽  
Vol 88 (3) ◽  
Author(s):  
Sergio C. Conte ◽  
Giulia Spagnol ◽  
Marco Confalonieri ◽  
Beatrice Brizi

The sedation plays an important role in the endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) procedure. The sedation can be Minimal (anxiolysis), Moderate (conscious sedation) or Deep. The ACCP guidelines suggest that moderate or deep sedation (DS) is an acceptable approach. In fact, several studies compare moderate versus deep sedation, but no study has been carried out to compare deep sedation versus minimal. We carried out a retrospective study to compare the Deep versus Minimal sedation (MiS) in patients undergoing EBUS-TBNA.  The primary end point was the diagnostic accuracy. The secondary end points were adequacy and sensitivity. We evaluated the LN size sampling, procedural time, complications and patient tolerance. Thirty-six patients underwent EBUS-TBNA, 16 under DS and 20 under MiS. The overall diagnostic accuracy for correct diagnosis was 92.9% in DS group and 94.1% in MiS group (p=0.554). Sample adequacy, defined as the percentage of patients with a specific diagnosis by EBUS-TBNA, was 87.5% (14 of 16) and 85% (17 of 20) for the DS group and MiS group, respectively, (p=0.788); the sensitivity was 92.9% in the DS group (95% CI, 73-100%) and 92.9% in the MiS group (95% CI, 77-100%) (p=0.463). There were no major complications in either group. Minor complications were 4 in MiS and 1 in DS (p=0.355).  The patients in the MiS group recalled the procedure more often compared to the other group (p=0.041). The majority of the patients would agree to undergo the same procedure again in the future in both groups (p=0.766).  In our experience EBUS-TBNA performed under MiS has comparable accuracy, adequacy, sensitivity, complications and patient satisfaction to DS, even if the sample was small.  Future prospective multicenter studies are needed to confirm our results.

2020 ◽  
Vol 14 ◽  
pp. 175346662090703 ◽  
Author(s):  
Xin He ◽  
Yanjun Wu ◽  
Haoyan Wang ◽  
Ganggang Yu ◽  
Bo Xu ◽  
...  

Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a widely used, safe, and accurate technique for obtaining pathological specimens to be used in the diagnosis of diseases involving lung hilar and mediastinal lymph node (LN) enlargement. However, application of the suction technique during EBUS-TBNA remains controversial. In addition, the effectiveness of the slow-pull capillary technique for the diagnosis of pancreatic masses was recently reported. The aim of this study was to compare the diagnostic accuracy of EBUS-TBNA using these two techniques. Methods: The accuracy, sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), and availability of tissue cores of the suction and slow-pull capillary techniques were studied retrospectively in patients who underwent EBUS-TBNA for the diagnosis of diseases involving lung hilar and mediastinal LN enlargement. Results: A total of 97 patients with hilar and mediastinal LN enlargement underwent EBUS-TBNA; 30 patients underwent the suction technique, 56 patients underwent the slow-pull capillary technique, 5 patients underwent both techniques, and 6 patients had failed operations. The accuracy, sensitivity, specificity, NPV, PPV, and the number of tissue cores obtained with the suction and slow-pull capillary techniques were 66.67% versus 85.71% ( p = 0.039), 43.75% versus 85.42% ( p < 0.001), 92.86% versus 87.5% ( p > 0.05), 59.09% versus 50% ( p > 0.05), 87.5% versus 97.62% ( p > 0.05), and 19 versus 50 ( p = 0.004), respectively. In both univariate and multivariate analyses, the acquisition of tissue core was significantly associated with the diagnostic accuracy of EBUS-TBNA. Moreover, the slow-pull capillary technique was significantly associated with the acquisition of tissue core in EBUS-TBNA. There were no significant differences between the two groups in the blood contamination of samples. Conclusions: Use of the slow-pull capillary technique in EBUS-TBNA can significantly increase the accuracy related to the diagnosis of diseases involving hilar and mediastinal LN enlargement by improving the acquisition of tissue core. The reviews of this paper are available via the supplemental material section.


Medicina ◽  
2018 ◽  
Vol 54 (2) ◽  
pp. 19 ◽  
Author(s):  
Marius Žemaitis ◽  
Greta Musteikienė ◽  
Skaidrius Miliauskas ◽  
Darius Pranys ◽  
Raimundas Sakalauskas

Background and Objective: Endobronchial ultrasound (EBUS) is a minimally invasive endobronchial technique, which uses ultrasound along with a bronchoscope to visualize the airway wall and structures that are adjacent to it. Indications for endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) are samplings of mediastinal, hilar lymph nodes, and tumors adjacent to airway walls. EBUS-TBNA has been used in our clinic since 2009. The aim of the study is to evaluate the sensitivity, specificity, positive and negative predictive value, and diagnostic accuracy of cytological and histological specimens, and the safety of EBUS-TBNA in an unselected patient population that has been referred to our hospital. Materials and Methods: We have retrospectively analyzed the medical documentation of 215 patients who had EBUS-TBNA performed in our clinic from April 2009 to February 2014. Results: There were 215 patients who underwent EBUS-TBNA. A total of 296 lymph nodes were sampled. EBUS-TBNA was diagnostic in 176 (81.9%) cases of cytological, 147 (68.4%) cases of histological, and 191 (88.9%) cases of the combined evaluation. In the lung cancer patients, EBUS-TBNA cytology had a sensitivity of 72.9% and histology of 72.9%, and in the sarcoidosis group, it had a cytology of 55.8% and histology of 64.5%. As all positive cytology and histology specimens were assumed to be true positive, specificity and positive predictive value (PPV) were 100%. The sensitivity and diagnostic accuracy was significantly higher when cytology and histology specimens were combined, compared with cytology or histology results evaluated separately (p < 0.05) (for lung cancer 84.1% and for sarcoidosis 78.8%). The sensitivity and diagnostic accuracy of EBUS-TBNA procedures increased significantly over time, with increased experience. There were no complications with EBUS-TBNA in our clinical practice. Conclusions: EBUS-TBNA had a high diagnostic yield and was safe in the diagnosis of lung cancer and sarcoidosis. It was most informative when cytology and histology were combined. The informative value of EBUS-TBNA histology increased with our experience.


2013 ◽  
Vol 10 (2) ◽  
pp. 121-126 ◽  
Author(s):  
Lonny B. Yarmus ◽  
Jason A. Akulian ◽  
Christopher Gilbert ◽  
Stephen C. Mathai ◽  
Srividya Sathiyamoorthy ◽  
...  

2020 ◽  
Vol 7 ◽  
Author(s):  
Mukunthan Murthi ◽  
Elio Donna ◽  
Sixto Arias ◽  
Nestor R. Villamizar ◽  
Dao M. Nguyen ◽  
...  

CHEST Journal ◽  
2009 ◽  
Vol 136 (4) ◽  
pp. 38S
Author(s):  
Lonny B. Yarmus ◽  
Hans J. Lee ◽  
Satish Kalanjeri ◽  
Gail Levin ◽  
Colin T. Gillespie ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document