scholarly journals Analysis of Chloramphenicol and Its Related Compound 2-Amino-1-(4-nitrophenyl)propane-1,3-diol by Reversed-Phase High-Performance Liquid Chromatography with UV Detection

2011 ◽  
Vol 2011 ◽  
pp. 1-6 ◽  
Author(s):  
Fuad Al-Rimawi ◽  
Maher Kharoaf

A simple and stability-indicating liquid chromatographic method is developed for the analysis of chloramphenicol and its related compound 2-amino-1-(4-nitrophenyl)propane-1,3-diol in two pharmaceutical forms. Liquid chromatography with a UV detector at a wavelength of 278 nm using a reversed phase C18 stationary phase has been employed in this study. Isocratic elution is employed using a mixture of sodium pentanesulfonate solution (0.012 M), acetonitrile, and glacial acetic acid (85 : 15 : 1, v/v). This new method is validated in accordance with USP requirements for new methods for assay determination, which include accuracy, precision, specificity, linearity and range. This method shows enough selectivity, sensitivity, accuracy, precision, and linearity range to satisfy Federal Drug Administration/International Conference on Harmonization regulatory requirements. The current method demonstrates good linearity over the range of 0.04–0.16 mg/mL of chloramphenicol. The accuracy of the method is 100.0% with a relative standard deviation of 0.1%. The precision of this method reflected by relative standard deviation of replicates is 0.1%. The method is sensitive with a detection limit of 0.005% for chloramphenicol. The related substance of chloramphenicol (2-amino-1-(4-nitrophenyl)propane-1,3-diol) can be selectively determined with a good resolution in two pharmaceutical forms: eye ointment and eye drops.

2003 ◽  
Vol 86 (4) ◽  
pp. 685-693 ◽  
Author(s):  
Guo-Fang Pang ◽  
Yan-Zhong Cao ◽  
Chun-Lin Fan ◽  
Jin-Jie Zhang ◽  
Xue-Min Li ◽  
...  

Abstract Eighteen laboratories participated in a collaborative study on the determination of clopidol residues in chicken muscle tissues by liquid chromatography. Of these, results from 16 laboratories which rigorously followed the method were subjected to statistical analysis. The method performance was assessed by all participants using 14 samples of chicken muscle fortified at concentrations ranging from 0.1 to 5.0 mg/kg. In addition, 9 participants each reported results for 6 clopidol-incurred samples in chicken muscle. Test portions were extracted with acetonitrile, and the extracts were purified with alumina and anion exchange resin solid-phase extraction cartridges in sequence. Clopidol was separated by reversed-phase liquid chromatography and quantified at 270 nm. Average recoveries ranged from 81.8 to 85.4%, reproducibility relative standard deviation (RSDR) ranged from 11.9 to 22.6%, and repeatability relative standard deviation (RSDr) ranged from 9.9 to 15.1%. For clopidol-incurred samples at concentrations of 0.100–0.687 mg/kg, the mean determination value range was 0.099–0.659 mg/kg; RSDR was 12.6–19.8%, RSDr was 3.1–8.5%; and HORRAT values were 0.7–1.1. The accuracy and precision of the method are in conformity with the requirements specified by AOAC INTERNATIONAL. The method was adopted Official First Action in April 2003.


2005 ◽  
Vol 88 (5) ◽  
pp. 1279-1291 ◽  
Author(s):  
John Szpylka ◽  
Jonathan W DeVries ◽  
S Bhandari ◽  
M H Bui ◽  
D Ji ◽  
...  

Abstract Twelve laboratories representing 4 countries participated in an interlaboratory study conducted to determine all-trans-β-carotene and total β-carotene in dietary supplements and raw materials. Thirteen samples were sent as blind duplicates to the collaborators. Results obtained from 11 laboratories are reported. For products composed as softgels and tablets that were analyzed for total β-carotene, the reproducibility relative standard deviation (RSDR) ranged from 3.35 to 23.09% and the HorRat values ranged from 1.06 to 3.72. For these products analyzed for trans β-carotene, the reproducibility relative standard deviation (RSDR) ranged from 4.28 to 22.76% and the HorRat values ranged from 0.92 to 3.37. The RSDr and HorRat values in the analysis of a beadlet raw material were substantial and it is believed that the variability within the material itself introduced significant variation in subsampling. The method uses high pressure liquid chromatography (LC) in the reversed-phase mode with visible light absorbance for detection and quantitation. If high levels of α-carotenes are present, a second LC system is used for additional separation and quantitation of the carotene species. It is recommended that the method be adopted as an AOAC Official Method.


2013 ◽  
Vol 448-453 ◽  
pp. 406-408
Author(s):  
Jing Liu ◽  
Xiao Na Ji ◽  
Qing Kai Ren ◽  
Sheng Shu Ai ◽  
Li Jun Wan ◽  
...  

We established a method fordetermination of nitrate in water by High Performance Liquid Chromatography(HPLC). The sample was analysed by HPLC-ADA and was quantitated by externalstandard method after being simply processed. This methd has the advantages ofhigh separation efficiency and fast analysis. The experiment result showed thatthe linearly dependent coefficient was0.994, the recovery rate was between 98.7%~105.7%,the relative standard deviation(RSD)wasless than 2.1 %, and the lowest detectable limit is 0.01ng (S/N=1.6).


1974 ◽  
Vol 57 (5) ◽  
pp. 1128-1131
Author(s):  
Phil B Bowman ◽  
Peter W Dame

Abstract A procedure is described for the determination of trichlorfon in a soluble powder formulation by gas-liquid chromatography. Silylation prevents on-column degradation of trichlorfon to dichlorvos. The procedure provides quantitative recovery from the formulation as demonstrated by a spiking study. A relative standard deviation of less than 2% was obtained for 6 replicate assays of a single lot of formulation. The mass spectral fragmentations of trichlorfon and trichlorfon-trimethylsilyl ether are described.


2005 ◽  
Vol 88 (2) ◽  
pp. 526-535 ◽  
Author(s):  
Hamide Z Senyuva ◽  
John Gilbert

Abstract An interlaboratory study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B1 and total aflatoxins in hazelnut paste at European regulatory limits. The test portion was extracted with methanol–water (6 + 4). The extract was filtered, diluted with phosphate-buffered saline (PBS) solution to a specified solvent concentration, and applied to an immunoaffinity column containing antibodies specific to aflatoxins. The aflatoxins were removed from the immunoaffinity column with methanol, and then quantified by reversed-phase LC with post-column derivatization (PCD) involving bromination. The PCD was achieved with electrochemically generated bromine (Kobra Cell®) followed by fluorescence detection (except for one participant who used pyridinum hydrobromide perbromide for bromination). Hazelnut paste, both naturally contaminated with aflatoxins and blank (<0.1 ng/g) for spiking by participants with aflatoxins, was sent to 14 collaborators in Belgium, The Netherlands, Spain, Turkey, the United Kingdom, and the United States. Test portions were spiked at levels of 4.0 and 10.0 ng/g for total aflatoxins by participants using supplied total aflatoxins standards. Recoveries for total aflatoxins and aflatoxin B1 averaged from 86 to 89%. Based on results for naturally contaminated samples (blind duplicates at 3 levels ranging from 4.0 to 11.8 ng/g total aflatoxins), the relative standard deviation for repeatability (RSDr) ranged from 2.3 to 3.4% for total aflatoxins and from 2.2 to 3.2% for aflatoxin B1. The relative standard deviation for reproducibility (RSDR) ranged from 6.1 to 7.0% for total aflatoxins and from 7.3 to 7.8% for aflatoxin B1. The method showed exceptionally good within-laboratory and between-laboratory precision for hazelnut paste, as evidenced by HORRAT values, which in all cases were significantly below target levels, the low levels of determination for both aflatoxin B1 and total aflatoxins.


1994 ◽  
Vol 77 (3) ◽  
pp. 672-674 ◽  
Author(s):  
Paul R Beuaars ◽  
Remmelt Van Dijk ◽  
Arie Brands

Abstract A collaborative study of the determination of p-tolu-enesulfonamide (p-TSA) in ice cream by a combination of continuous flow and on-line liquid chromatography was conducted. Seven ice cream samples containing 0-6.35 mg p-TSA/kg at 4 levels (1 blank and 3 pairs of split level samples) were analyzed by 11 laboratories. For all samples analyzed, the repeatability relative standard deviation varied from 2.08 to 3.67%, whereas the reproducibility relative standard deviation ranged from 7.79 to 11.68%. The average p-TSA values for the split levels 1,2, and 3 were 0.55,1.02, and 4.44 mg p-TSA/kg, respectively, with mean recoveries ranging from 76 to 79% (overall recovery range for all levels, 63-101 %). No false positive results were reported for the blank sample, and no interference was encountered by the presence of vanillin in samples. The method has been adopted first action by AOAC INTERNATIONAL.


2001 ◽  
Vol 84 (2) ◽  
pp. 444-450 ◽  
Author(s):  
A Catherine Entwisle ◽  
Alison C Williams ◽  
Peter J Mann ◽  
Joanne Russell ◽  
Philip T Slack ◽  
...  

Abstract A collaborative study was conducted to evaluate a liquid chromatography (LC) method for ochratoxin A using sequential phenyl silane and immunoaffinity column cleanup. The method was tested at 3 different levels of ochratoxin A in roasted coffee, which spanned the range of possible future European regulatory limits. The test portion was extracted with methanol and sodium bicarbonate by shaking for 30 min. The extract was filtered, centrifuged, and then cleaned up on a phenyl silane column before being eluted from the washed column with methanol–water. The eluate was diluted with phosphate-buffered saline (PBS) and applied to an ochratoxin A immunoaffinity column, which was washed with water. The ochratoxin A was eluted with methanol, the solvent was evaporated, and the residue was redissolved in injection solvent. After injection of this solution onto a reversed-phase LC apparatus, ochratoxin A was measured by fluorescence detection. Eight laboratory samples of low-level naturally contaminated roasted coffee and 2 laboratory samples of blank coffee (< 0.2 ng/g ochratoxin A at the signal-to-noise ratio of 3:1), along with ampules of ochratoxin A calibrant and spiking solutions, were sent to 15 laboratories in 13 different European countries. Test portions of the laboratory samples were spiked at levels of 4 ng/g ochratoxin A, and recoveries ranged from 65 to 97%. Based on results for spiked blank material (blind duplicates) and naturally contaminated material (blind duplicates at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 2 to 22% and the relative standard deviation for reproducibility (RSDR) ranged from 14 to 26%. The method showed acceptable within- and between-laboratory precision, as evidenced by HORRAT values, at the low level of determination for ochratoxin A in roasted coffee.


2009 ◽  
Vol 92 (3) ◽  
pp. 820-823 ◽  
Author(s):  
Andréia de Haro Moreno ◽  
Hérida Regina Nunes Salgado

Abstract A new UV spectrophotometric method was developed for quantitative evaluation of ceftazidime preparations. The UV detector was set at 255 nm. Beer's law is obeyed in the concentration range of 7.014.0 g/mL. The method was found to be selective, linear, accurate, and precise in the specified ranges. Intra- and interday variability for the method were <2 relative standard deviation. Common excipients used as additives in pharmaceutical preparations do not interfere with the proposed method. This method was successfully used for quantification of ceftazidime in pure form and in pharmaceutical preparations.


1994 ◽  
Vol 77 (6) ◽  
pp. 1512-1521 ◽  
Author(s):  
Mary W Trucksess ◽  
Michael E Stack ◽  
Stanley Nesheim ◽  
Richard H Albert ◽  
Thomas R Romer

Abstract An AOAC/IUPAC collaborative study was conducted to evaluate the effectiveness of a multifunctional column for the determination of aflatoxins. The test portion is extracted with acetonitrile–water (9 + 1), the extract is filtered, and the filtrate is passed through the column. The aflatoxins in the eluate are determined by reversed-phase liquid chromatography after derivatization with trifluoroacetic acid. Naturally contaminated corn, almonds, Brazil nuts, peanuts, and pistachio nuts spiked with total aflatoxins at 5,10,20, and 30 ng/g were sent to 12 collaborators in the United States, Denmark, France, Japan, and Switzerland. Eleven collaborators completed the study. Average recoveries of total aflatoxins for each spike level for the various commodities (excluding Brazil nuts at 5 ng/g) were 93,97,95, and 95%, respectively; the repeatability relative standard deviation (RSDr) ranged from 6.0 to 23.2% and the reproducibility relative standard deviation (RSDR) ranged from 12.0 to 69.4%. The multifunctional column coupled with a liquid chromatographic method for determination of aflatoxins in corn, almonds, Brazil nuts, peanuts, and pistachio nuts has been adopted first action by AOAC INTERNATIONAL.


2001 ◽  
Vol 84 (4) ◽  
pp. 1116-1124 ◽  
Author(s):  
Joerg Stroka ◽  
Elke Anklam ◽  
Urban Joerissen ◽  
John Gilbert ◽  
A Barmark ◽  
...  

Abstract A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B1 in a milk powder based infant formula at a possible future European regulatory limit (0.1 ng/g). The test portion was extracted with methanol–water (8 + 2 [v + v]), filtered, diluted with water, and applied to an immunoaffinity column. The column was washed with water to remove interfering compounds, and the purified aflatoxin B1 was eluted with methanol. The separation and determination of the aflatoxin B1 was performed by reversed-phase LC and detected by fluorescence after postcolumn derivatization (PCD) involving bromination. PCD was achieved with either pyridinum hydrobromide perbromide (PBPB) or an electrochemical (Kobra) cell by addition of bromide to the mobile phase. The baby food (infant formula) test samples, both spiked and naturally contaminated with aflatoxin B1, were sent to 14 laboratories in 13 different European countries. Test portions were spiked at levels of 0.1 and 0.2 ng/g for aflatoxin B1. Recoveries ranged from 101 to 92%. Based on results for spiked test samples (blind pairs at 2 levels) and naturally contaminated test samples (blind pairs at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 3.5 to 14%. The relative standard deviation for reproducibility (RSDR) ranged from 9 to 23%. Nine participants used PBPB derivatization, and 5 particpants used the Kobra cell. There was no evidence of method performance depending on the derivatization method used. The method showed acceptable within- and between-laboratory precision for baby food matrix, as evidenced by HORRAT values, at the target levels of determination for aflatoxin B1.