Real-Time Asset Optimisation - Integrity Management of Flexible Pipe Systems: Meeting the Challenge

2017 ◽  
Author(s):  
Geoff Eckold ◽  
Roger White
Author(s):  
Carlos Eduardo Costa Valle Longo ◽  
Guilherme de Salles Bessa ◽  
Marcelo Brack ◽  
Ota´vio Campos de Arau´jo ◽  
Wallace Bartholomeu e Silva

Nowadays, due to the increasing importance of the HSE and also the operational availability requirements, one of the most important challenges for producing oil and gas at subsea environments is to have a mature methodology for quantifying risks. The main objective of this paper is to present a strategy for running risk analysis of flexible pipe systems. These systems are extensively used by Petrobras to flow different kinds of fluids in deep water offshore scenarios. The strategy presented herein includes the classification of threats and the potential failure mechanisms. Probabilistic figures are established depending on the historic data of the components of the flexible pipe system and also on the theoretical results obtained from available models for determination of the component remaining life. The strategy is based on the previous definition of inference rules and technical criteria for probability, consequence and risk assessments. The final goal is to have an adequate tool to help Operators to take decisions, to establish strategies and to improve flexible pipe integrity management.


2021 ◽  
Vol 73 (01) ◽  
pp. 65-66
Author(s):  
Chris Carpenter

This article, written by JPT Technology Editor Chris Carpenter, contains highlights of paper SPE 197168, “Digitalize Asset-Integrity Management by Remote Monitoring,” by Mohamed Sahid, ADNOC, prepared for the 2019 Abu Dhabi International Petroleum Exhibition and Conference, Abu Dhabi, 11-14 November. The paper has not been peer reviewed. Monitoring of corrosion in process pipelines has always been of paramount importance in ensuring plant-asset integrity. Similarly, steam traps play an important role in ensuring steam quality and, thus, the integrity of critical assets in the plant. The complete paper discusses these two aspects of monitoring asset integrity - real-time corrosion monitoring and real-time steam-trap monitoring - as implemented by the operator. The authors highlight the importance of digitization by means of implementing wireless technology and making data available in remote work stations in real time. Real-Time Corrosion-Monitoring System Corrosion coupons and electrical resistance probes are among the most-tried and -tested methods to monitor corrosion, but the authors detail shortcomings of these systems, focusing their efforts on the option of using nonintrusive ultrasonic sensors for corrosion monitoring. Fixed ultrasonic thickness (UT) monitoring systems measure a localized thickness of vessel wall or pipe through the use of sound waves. They are the fastest method to measure wall thickness and wall loss reliably. The wall thickness is calculated from the reflection of the ultrasonic signal at both external and internal surfaces. UT systems normally include a transducer and a pulser/receiver. The type of transducer used for this application is the ultrasonic transducer, which can be either piezoelectric or variable-capacitive. The pulser generates short electric pulses of energy at a constant rate, which are converted by the transducer into short, high-frequency ultrasonic sound pulses. These pulses are then directed into the material. Any discontinuation or impurity in the path of the ultrasonic sound wave will be reflected and received by the transducer, transformed into an electric signal, and amplified by the receiver to be projected onto the display (in the case of portable UT instruments). Depending on the intensity shown on the display, information about the impurity or discontinuity, such as size, orientation, and location, can be derived accurately. The shortcomings of using portable UT sensors have been overcome by the introduction of permanent UT sensors, which provide wall-thickness measurement continuously at one location in real time. Because these sensors remain fixed at one location for years, it is possible to analyze corrosion at a single point over time, thus detecting early corrosion onset. Real-Time UT Gauging. The operator installed the real-time corrosion-monitoring system in its offshore associated gas (OAG) unit. A UK-based vendor provided UT sensors along with data-management and -viewing software to support data interpretation. Twenty locations were identified in various plants of the OAG unit on the basis of criticality and previously recorded corrosion levels.


2019 ◽  
Author(s):  
Amit Kumar ◽  
Tareq Al Daghar ◽  
Ali Al Shehhi ◽  
Brendon Keinath ◽  
Mohan Kulkarni ◽  
...  

2015 ◽  
Author(s):  
I. H. F. Santos ◽  
E. Vardaro ◽  
E. Goes ◽  
V. S. Lopes ◽  
A. Vaillant ◽  
...  

Author(s):  
Marcelo Brack ◽  
Sergio Roberto Alves Mendes ◽  
Rodrigo Cesar Lancelotti Campos ◽  
Luiz Antonio Lobianco e Souza

Many of the current practices applied for offshore production managing emphasize those aspects related to the efficiency of oil & gas production and exportation. Nowadays, due not only to the inherent technical challenges associated to deep-water applications but also to the increasing importance of the HSE aspects and requirements faced by the industry, a crescent demand to implement a philosophy which focalizes safety, reliability and integrity of their subsea flowing systems is taking place. The handling of monitored data in order to help the pipe operator to control fluid transportation throughout flexible pipes is an old practice performed by Petrobras and other oil companies in the world. However, the idea of acquiring a product which has been conceived, designed and manufactured with both intrinsic monitoring and expert systems is a recent idea. The tendency of the main flexible pipe manufactures is normally to face the problem from the traditional point of view: those systems are considered dissociated one from the other and as appendices to be installed, in the field, after system connection and start-up. Experience demonstrates that the installation of those systems during the operation phase has a number of limitations, restrictions, and associated problems. The main objective of this paper is to present an integrity management strategy based on the concept of the self-monitored flexible riser. Self-monitoring is understood as the own capacity of a product (flexible pipe and components with built-in devices) to acquire data about itself and make use of data from the internal and external environments, during its service life. Monitored data is then processed in order to generate relevant information for the fluid transportation business. The basic premise is to select, during product conception phase, some key-parameters to be further monitored, during the operation phase. The selection is determined by technical criteria depending on the potential failure mechanisms and modes related to the particularities of each different application.


Author(s):  
M. O. Brandão ◽  
F. Pires ◽  
C. Benirschke ◽  
E. Almeida ◽  
T. Iecker ◽  
...  

Abstract The development of Brazil Offshore fields using flexible pipes took the advantage of the possibility to move around lines, anticipate the production and postpone the decision of where exactly the development phase wells should be placed, making the drilling campaign easier, cheaper and faster. For the Pre-Salt fields, mainly in Santos Basin, it is observed high concentrations of H2S and CO2, two major impact contaminants for the metallic layers of the flexible pipe. A new failure mode by SCC is the most concerning one and have several approaches either focused on the installed fleet or focused in the next pipes to be delivered. SCC is a condition that induces cracks in the pipes metallic layers and need three elements to happen: water, stress and susceptible material. If one of these three elements is suppressed, the phenomena is not to happen. This paper will cover and present a design of a seal tight end fitting also with capabilities to be seal tested from the shop during the factory acceptance test and further means to identify if the flexible pipe section is flooded or dry visually, using ROV This information is key for the integrity management of the flexible pipes applied to pre salt fields to assure the most extent of the service life.


Sign in / Sign up

Export Citation Format

Share Document