scholarly journals Activation of matrix-bound endogenous proteases by self-etch adhesives

2020 ◽  
Vol 39 (6) ◽  
pp. 1044-1049
Author(s):  
Bebek Serra OGUZ AHMET ◽  
Roda SESEOGULLARI-DIRIHAN ◽  
Arzu TEZVERGIL-MUTLUAY
1981 ◽  
Author(s):  
M Yamamoto ◽  
K Watanabe ◽  
Y Ando ◽  
H Iri ◽  
N Fujiyama ◽  
...  

It has been suggested that heparin caused potentiation of aggregation induced by ADP or epinephrine. The exact mechanism of heparin-induced platelet activation, however, remained unknown. In this paper, we have investigated the role of anti-thrombin III ( AT ) in heparin-induced platelet activation using purified AT and AT depleted plasma. When ADP or epinephrine was added to citrated PRP one minute after addition of heparin ( 1 u/ml, porcine intestinal mucosal heparin, Sigma Co. USA ), marked enhancement of platelet aggregation was observed, compared with the degree of aggregation in the absence of heparin. However, in platelet suspensions prepared in modified Tyrode’s solution, heparin exhibited no potentiating effect on platelet aggregation induced by epinephrine or ADP. Potentiation of epinephrine- or ADP-induced platelet aggregation by heparin was demonstrated when purified AT was added to platelet suspensions at a concentration of 20 μg/ml. AT depleted plasma, which was prepared by immunosorption using matrix-bound antibodies to AT, retained no AT, while determination of α1-antitrypsinα2- macroglobulin and fibrinogen in AT depleted plasma produced values which corresponded to those of the original plasma when dilution factor was taken into account. The activities of coagulation factors were also comparable to those of the original plasma. Heparin exhibited potentiating effect on ADP- or epinephrine-induced aggregation of platelets in original plasma, but no effect in AT depleted plasma. When purified AT was added back to AT depleted plasma at a concentration of 20 μg/ml, potentiation of platelet aggregation by heparin was clearly demonstrated.Our results suggest that effect of heparin on platelet aggregation is also mediated by anti-thrombin III.


2019 ◽  
pp. 61-67
Author(s):  
Xuan Anh Ngoc Ho ◽  
Anh Chi Phan ◽  
Toai Nguyen

Background: Class II restoration with zirconia inlay is concerned by numerous studies about the luting coupling between zirconia inlay and teeth. The present study was performed to evaluate the microleakage of Class II zirconia inlayusing two different luting agents and compare to direct restoration using bulk fill composite. Aims: To evaluate the microleakage of Class II restorations using three different techniques. Materials and methods: The study was performed in laboratory with three groups. Each of thirty extracted human teeth was prepared a class II cavity with the same dimensions, then these teeth were randomly divided into 3 groups restored by 3 different approaches. Group 1: zirconia inlay cemented with self-etch resin cement (Multilink N); Group 2: zirconia inlay cemented with resin-modified glass ionomer cement (Fuji Plus); Group 3: direct composite restoration using bulk fill composite(Tetric N-Ceram Bulk Fill). All restorations were subjected to thermal cycling (100 cycles 50C – 55 0C), then immersed to 2% methylene blue solution for 24 hours. The microleakage determined by the extent of dye penetration along the gingival wall was assessed using two methods: quantitative and semi-quantitative method. Results: Among three types of restorations, group 1 demonstrated the significantly lower rate of leakage compared to the others, while group 2 and 3 showed no significant difference. Conclusion: Zirconia inlay restoration cemented with self-etch resin cement has least microleakage degree when compare to class II zirconia inlay restoration cemented with resin-modified glass ionomer cement and direct composite restoration using bulk fill composite. Key words: inlay, zirconia ceramic, class II restoration, microleakage.


2019 ◽  
Vol 70 (7) ◽  
pp. 2608-2613
Author(s):  
Larisa Simona Deac ◽  
Kamel Earar ◽  
Adela Loredana Colceriu Burtea ◽  
Alexandra Stefania Berghe ◽  
Aurora Antoniac ◽  
...  

This study evaluates and compares by dye penetration method and SEM photomicrographs the sealing obtained using two different classes of adhesive systems (etch-and-rinse and self-etch with selective etching) with SDR (Dentsply) bulk fill composite. 84 class V cavities were prepared on oral and vestibular face of 42 intact, freshly extracted wisdom teeth. The cavities were randomly divided in two groups and restored: Group 1 with prime &bond one select (Dentsply) and SDR (Dentsply) and Group 2 with prime&bond one Etch&Rinse (Dentsply) and SDR (Dentsply). Prime&bond one Select (Dentsply) is a single component adhesive and can be used in self etch mode, in selective enamel etch mode, or in etch-and-rinse mode. We chosen for this study the selective etch of the enamel mode. Prime&bond one Etch Rinse (Dentsply) is a universal etch-and-rinse one-bottle dental adhesive, designed to be used in two steps. The bulk fill composites are commonly used in modern dentistry due to their properties of low polymerization shrinkage and curing in layer of 4 mm depth, offering the practitioner a fast clinical procedure with good results. The results showed a good sealing at enamel and dentin margins with no statistically significant difference between adhesives, even though the mean of enamel infiltration was smaller for Group1. Furthermore the results show that there were differences between the two groups, for the infiltrations at the enamel, the values of microleakage being arithmetically higher for Group 1, but with no statistically difference between the two groups.SEM images showed for both groups a good adhesion surface with the tooth, but the hybrid layer of the total-etch adhesives is different from the hybrid layer formed by self etch adhesives, in terms of thickness, uniformity. In conclusion both adhesive systems have equivalent sealing qualities and can be successfully used with SDR.


2021 ◽  
Vol 105 ◽  
pp. 103555
Author(s):  
Jana Schmidt ◽  
Sandra Krohn ◽  
René Kallies ◽  
Hartmut Schneider ◽  
Katharina Zeller ◽  
...  

2015 ◽  
Vol 2015 ◽  
pp. 1-5 ◽  
Author(s):  
Babacar Faye ◽  
Mouhamed Sarr ◽  
Khaly Bane ◽  
Adjaratou Wakha Aidara ◽  
Seydina Ousmane Niang ◽  
...  

This study evaluated the one-year clinical performance of a one-step, self-etch adhesive (Optibond All-in-One, Kerr, CA, USA) combined with a composite (Herculite XRV Ultra, Kerr Hawe, CA, USA) to restore NCCLs with or without prior acid etching. Restorations performed by the same practitioner were evaluated at baseline and after 3, 6, and 12 months using modified USPHS criteria. At 6 months, the recall rate was 100%. The retention rate was 84.2% for restorations with prior acid etching, but statistically significant differences were observed between baseline and 6 months. Without acid etching, the retention rate was 77%, and no statistically significant difference was noted between 3 and 6 months. Marginal integrity (93.7% with and 87.7% without acid etching) and discoloration (95.3% with and 92.9% without acid etching) were scored as Alpha or Bravo, with better results after acid etching. After one year, the recall rate was 58.06%. Loss of pulp vitality, postoperative sensitivity, or secondary caries were not observed. After one year retention rate was of 90.6% and 76.9% with and without acid conditioning. Optibond All-in-One performs at a satisfactory clinical performance level for restoration of NCCLs after 12 months especially after acid etching.


2021 ◽  
Vol 109 ◽  
pp. 103665
Author(s):  
Citra Kusumasari ◽  
Ahmed Abdou ◽  
Masatoshi Nakajima ◽  
Junji Tagami

2021 ◽  
Vol 10 (8) ◽  
pp. 1769
Author(s):  
Katariina Öörni ◽  
Petri T. Kovanen

Circulating low-density lipoprotein (LDL) particles enter the arterial intima where they bind to the extracellular matrix and become modified by lipases, proteases, and oxidizing enzymes and agents. The modified LDL particles aggregate and fuse into larger matrix-bound lipid droplets and, upon generation of unesterified cholesterol, cholesterol crystals are also formed. Uptake of the aggregated/fused particles and cholesterol crystals by macrophages and smooth muscle cells induces their inflammatory activation and conversion into foam cells. In this review, we summarize the causes and consequences of LDL aggregation and describe the development and applications of an assay capable of determining the susceptibility of isolated LDL particles to aggregate when exposed to human recombinant sphingomyelinase enzyme ex vivo. Significant person-to-person differences in the aggregation susceptibility of LDL particles were observed, and such individual differences largely depended on particle lipid composition. The presence of aggregation-prone LDL in the circulation predicted future cardiovascular events in patients with atherosclerotic cardiovascular disease. We also discuss means capable of reducing LDL particles’ aggregation susceptibility that could potentially inhibit LDL aggregation in the arterial wall. Whether reductions in LDL aggregation susceptibility are associated with attenuated atherogenesis and a reduced risk of atherosclerotic cardiovascular diseases remains to be studied.


2010 ◽  
Vol 04 (04) ◽  
pp. 367-373 ◽  
Author(s):  
Sevi Burcak Cehreli ◽  
Asli Guzey ◽  
Neslihan Arhun ◽  
Alev Cetinsahin ◽  
Bahtiyar Unver

Objectives: The aim of this in vitro study is to determine (1) shear bond strength (SBS) of brackets bonded with self-etch and total-etch adhesive after ozone treatment (2) bond failure interface using a modified Adhesive Remnant Index (ARI).Methods: 52 premolars were randomly assigned into four groups (n=13) and received the following treatments: Group 1: 30 s Ozone (Biozonix, Ozonytron, Vehos Medikal, Ankara, Turkey) application + Transbond Plus Self-Etching Primer (SEP) (3M) + Transbond XT (3M), Group 2: Transbond Plus SEP + Transbond XT, Group 3: 30 s Ozone application + 37% orthophosphoric acid + Transbond XT Primer (3M) + Transbond XT, Group 4: 37% orthophosphoric acid + Transbond XT Primer + Transbond XT. All samples were stored in deionised water at 37oC for 24 hours. Shear debonding test was performed by applying a vertical force to the base of the bracket at a cross-head speed of 1 mm/min.Results: The mean SBS results were Group 1: 10.48 MPa; Group 2: 8.89 MPa; Group 3: 9.41 MPa; Group 4: 9.82 MPa. One-Way Variance Test revealed that the difference between the groups was not statistically significant (P=0.267). Debonded brackets were examined by an optical microscope at X16 magnification to determine the bond failure interface using a modified ARI. The results were (mean) Group 1: 2.38; Group 2: 1.31; Group 3: 3.00; Group 4: 1.92. Multiple comparisons showed that Groups 1 and 2, 2 and 3, 3 and 4 were statistically different (P=0.014, P<.001 and P=0.025).Conclusions: Ozone treatment prior to bracket bonding does not affect the shear bond strength. (Eur J Dent 2010;4:367-373)


Sign in / Sign up

Export Citation Format

Share Document