scholarly journals Effect of the amount of light energy transmitted through CAD/CAM resin block on bonding performance of four types of resin cement adhesive systems

2020 ◽  
Vol 39 (5) ◽  
pp. 792-802
Author(s):  
Kaho ABE ◽  
Takashi ASANO ◽  
Masahiro AIDA ◽  
Norihiro NISHIYAMA ◽  
Osamu KOMIYAMA
2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Kyoko Ishikawa ◽  
Monica Yamauti ◽  
Antonin Tichy ◽  
Masaomi Ikeda ◽  
Takeshi Ueno ◽  
...  

Purpose. The potential of UV-mediated photofunctionalization to enhance the resin-based luting agent bonding performance to aged materials was investigated. Methods. Sixty samples of each material were prepared. Yttria-stabilized zirconia (YZr) and Pd-Au alloy (Pd-Au) plates were fabricated and sandblasted. Lithium disilicate glass-ceramic (LDS) was CAD-CAM prepared and ground with #800 SiC paper. Half of the specimens were immersed in machine oil for 24 h to simulate the carbon adsorption. Then, all of the specimens (noncarbon- and carbon-adsorbed) were submitted to UV-mediated photofunctionalization with a 15 W UV-LED (265 nm, 300 mA, 7692 μW/cm2) for 0 (control groups), 5, and 15 min and subjected to contact angle (Ɵ) measurement and bonded using a resin cement (Panavia™ V5, Kuraray Noritake, Japan). The tensile bond strength (TBS) test was performed after 24 h. The Ɵ (°) and TBS (MPa) data were statistically analyzed using two-way ANOVA and Bonferroni correction tests ( α = 0.05 ). Results. In the carbon-adsorbed groups, UV-mediated photofunctionalization for 5 min significantly decreased Ɵ of all materials and increased TBS of YZr, and UV for 15 min significantly increased the TBS of LDS and Pd-Au. In noncarbon-adsorbed groups, UV-photofunctionalization did not significantly change the Ɵ or TBS except YZr specimens UV-photofunctionalized for 15 min. Conclusion. UV-mediated photofunctionalization might have removed the adsorbed hydrocarbon molecules from the materials’ surfaces and enhanced bond strengths of Panavia™ V5 to YZr, LDS, and Pd-Au. Additionally, UV-mediated photofunctionalization improved the overall TBS of YZr. Further investigation on the optimum conditions of UV photofunctionalization on indirect restorative materials should be conducted.


2017 ◽  
Vol 42 (3) ◽  
pp. 284-296 ◽  
Author(s):  
EC Martini ◽  
SO Parreiras ◽  
MF Gutierrez ◽  
AD Loguercio ◽  
A Reis

SUMMARY Objectives: The aim of this study was to investigate the effect of different protocols of 17% ethylene diamine tetra-acetic acid (EDTA) conditioning on the etching pattern and immediate bond strength of universal adhesives to enamel and sclerotic dentin. Methods and Materials: Forty bovine teeth with sclerotic dentin and 20 human third molars were randomly divided into eight groups resulting from the combination of the main factors surface treatment (none, two-minute EDTA conditioning manual application, 30-second EDTA manual application, 30-second EDTA sonic application) and adhesives systems (Scotchbond Universal Adhesive [SBU] and Prime & Bond Elect [PBE]). Resin-dentin and enamel-dentin bond specimens were prepared and tested under the microtensile bond strength (μTBS) and microshear bond strength (μSBS) tests, respectively. The etching pattern produced on the unground enamel and the sclerotic dentin surfaces under the different protocols and adhesive systems was evaluated under scanning electron microscopy. Results: For enamel, only the main factor adhesive was significant (p<0.0001), with SBU showing the highest μSBS. In sclerotic dentin, the lowest mean was observed for the group without EDTA application and the highest mean in the group with EDTA application with the sonic device for 30 seconds. Regardless of the EDTA protocol, the highest means of μTBS were observed for SBU (p<0.05). Conclusions: EDTA conditioning improves the bonding performance of universal adhesives in the self-etch mode on sclerotic dentin, mainly when applied for 30 seconds with the aid of a sonic device. EDTA pretreatment also improves the retentive etching pattern of enamel, but it does not result in higher enamel bond strength.


Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 7058
Author(s):  
Akane Chin ◽  
Masaomi Ikeda ◽  
Tomohiro Takagaki ◽  
Toru Nikaido ◽  
Alireza Sadr ◽  
...  

The purpose of this study was to evaluate the effect of one week of Computer-aided design/Computer-aided manufacturing (CAD/CAM) crown storage on the μTBS between resin cement and CAD/CAM resin composite blocks. The micro-tensile bond strength (μTBS) test groups were divided into 4 conditions. There are two types of CAD/CAM resin composite blocks, namely A block and P block (KATANA Avencia Block and KATANA Avencia P Block, Kuraray Noritake Dental, Tokyo, Japan) and two types of resin cements. Additionally, there are two curing methods (light cure and chemical cure) prior to the μTBS test—Immediate: cementation was performed immediately; Delay: cementation was conducted after one week of storage in air under laboratory conditions. The effect of Immediate and Delayed cementations were evaluated by a μTBS test, surface roughness measurements, light intensity measurements, water sorption measurements and Scanning electron microscope/Energy dispersive X-ray spectrometry (SEM/EDS) analysis. From the results of the μTBS test, we found that Delayed cementation showed significantly lower bond strength than that of Immediate cementation for both resin cements and both curing methods using A block. There was no significant difference between the two types of resin cements or two curing methods. Furthermore, water sorption of A block was significantly higher than that of P block. Within the limitations of this study, alumina air abrasion of CAD/CAM resin composite restorations should be performed immediately before bonding at the chairside to minimize the effect of humidity on bonding.


2019 ◽  
Vol 18 (4) ◽  
pp. 764-772
Author(s):  
Asa Yazdani Fard ◽  
Zuryati Ab Ghani ◽  
Zaihan Ariffin ◽  
Dasmawati Mohamad

Background: Studies on microleakage of Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM) crowns are abundant. However many of them are inconclusive, especially those using self adhesive cements. Aims: To compare the microleakage between CAD/CAM crowns milled out of feldspathic ceramic and resin nano ceramics, cemented with three resin cements. Materials and Methods: Crown preparation was made on 54 extracted human premolars. Impressions were captured optically using CEREC 3D machine intraoral camera, and crowns were milled from feldspathic ceramic (CEREC® Blocs PC, VITA) and resin nano ceramic (Lava™ Ultimate CAD/CAM Restorative, 3M ESPE) blocks. The crowns were then cemented with three cements (n = 9); RelyX™ U200 Self-Adhesive Resin Cement (3M ESPE); NX3 Nexus ® cement with two-step etch-and-rinse adhesive (Kerr Corporation) or three/multistep etch-and-rinse resin cement, Variolink® II/Syntac Classic (Ivoclar Vivadent). The specimens were kept in water for 24 hours, thermocycled, and then soaked in methylene blue dye for 24 hours, before being sectioned mesiodistally. Microleakage was assessed using a fivepoint scale using stereomicroscope. Statistical analysis of the data was carried out using ONEWay ANOVA. Results: CEREC® Blocs PC crowns showed significantly less microleakage (p< 0.001) compared to Lava™ Ultimate. RelyX™ U200 showed significantly lower microleakage (p< 0.001) compared to other cements. Combination of Lava™ Ultimate crown cemented with RelyX™ U200 showed the least microleakage (p< 0.001). Conclusions: The microleakage scores were affected by the types of crown and cements. Bangladesh Journal of Medical Science Vol.18(4) 2019 p.764-772


Odontology ◽  
2019 ◽  
Vol 107 (4) ◽  
pp. 491-499 ◽  
Author(s):  
Omer Sagsoz ◽  
Nurdan Polat Sagsoz ◽  
Mustafa Tolga Yurtcan ◽  
Niyazi Ozcelik

2018 ◽  
Vol 2018 ◽  
pp. 1-6 ◽  
Author(s):  
Mustafa Mehmet Özarslan ◽  
Özlem Üstün ◽  
Ulviye Sebnem Buyukkaplan ◽  
Çağatay Barutcigil ◽  
Nurullah Türker ◽  
...  

Adult orthodontics may confront problems related to the bonding performance of orthodontic brackets to new generation restorative materials used for crown or laminate restorations. The aim of the present study was to investigate the shear bond strength of ceramic brackets to two new generation CAD/CAM interpenetrating network composite and nanoceramic composite after different surface treatments. Er,Cr:YSGG Laser, hydrofluoric acid (9%), sandblasting (50 μm Al2O3), and silane were applied to the surfaces of 120 CAD/CAM specimens with 2 mm thickness and then ceramic brackets were bonded to the treated surfaces of the specimens. Bond strength was evaluated using the shear bond strength test. According to the results, CAD/CAM block types and surface treatment methods have significant effects on shear bond strength. The lowest bond strength values were found in the specimens treated with silane (3.35 ± 2.09 MPa) and highest values were found in the specimens treated with sandblast (8.92 ± 2.77 MPa). Sandblasting and hydrofluoric acid surface treatment led to the most durable bonds for the two types of CAD/CAM blocks in the present study. In conclusion, different surface treatments affect the shear bond strength of ceramic brackets to CAD/CAM interpenetrating network composite and nanoceramic composite. Among the evaluated treatments, sandblasting and hydrofluoric acid application resulted in sufficient bonding strength to ceramic brackets for both of the CAD/CAM materials.


Author(s):  
Andressa Borin Venturini ◽  
Vinícius Felipe Wandscher ◽  
Ana Maria Estivalete Marchionatti ◽  
Edoardo Evangelisti ◽  
Gabriela Freitas Ramos ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document