scholarly journals Self-etch or etch-and-rinse mode did not affect the microshear bond strength of a universal adhesive to primary dentin

2016 ◽  
Vol 35 (2) ◽  
pp. 174-179 ◽  
Author(s):  
Benjaporn THANARATIKUL ◽  
Busayarat SANTIWONG ◽  
Choltacha HARNIRATTISAI
2016 ◽  
Vol 41 (5) ◽  
pp. 481-490 ◽  
Author(s):  
AM Cardenas ◽  
F Siqueira ◽  
J Rocha ◽  
AL Szesz ◽  
M Anwar ◽  
...  

SUMMARY Objectives: To evaluate the effect of application protocol in resin–enamel microshear bond strength (μSBS), in situ degree of conversion, and etching pattern of three universal adhesive systems. Methods and Materials: Sixty-three extracted third molars were sectioned in four parts (buccal, lingual, and proximals) and divided into nine groups, according to the combination of the main factors—Adhesive (Clearfil Universal, Kuraray Noritake Dental Inc, Tokyo, Japan; Futurabond U, VOCO, Cuxhaven, Germany; and Scotchbond Universal Adhesive, 3M ESPE, St Paul, MN, USA)—and enamel treatment/application time (etch-and-rinse mode [ER], self-etch [SE] application for 20 seconds [SE20], and SE application for 40 seconds [SE40]). Specimens were stored in water (37°C/24 h) and tested at 1.0 mm/min (μSBS). The degree of conversion of the adhesives at the resin–enamel interfaces was evaluated using micro-Raman spectroscopy. The enamel-etching pattern was evaluated under a scanning electron microscope. Data were analyzed with two-way analysis of variance and Tukey test (α=0.05). Results: In general, the application of the universal adhesives in the SE40 produced μSBS and degree of conversion that were higher than in the SE20 (p<0.01) and similar to the ER mode. The deepest enamel-etching pattern was obtained in the ER mode, followed by the SE40. Conclusions: The active and prolonged application of universal adhesives in the SE mode may be a viable alternative to increase the degree of conversion, etching pattern, and resin–enamel bond strength.


Author(s):  
Masoud Fallahinejad Ghajari ◽  
Amir Ghasemi ◽  
Mohammadreza Badiee ◽  
Zahra Abdolazimi ◽  
Alireza Akbarzadeh Baghban

Objectives: This study aimed to assess the microshear bond strength (MSBS) of Scotchbond Universal adhesive, used in self-etch and etch-and-rinse modes, to primary and permanent dentin at 24 hours and six months. Materials and Methods: A total of 88 composite micro-cylinders were divided into eight groups (n=11) as follows: (A) Etch-and-rinse, 24 hours, primary dentin; (B) Self-etch, 24 hours, primary dentin; (C) Etch-and-rinse, six months, primary dentin; (D) Self-etch, six months, primary dentin; (E) Etch-and-rinse, 24 hours, permanent dentin; (F) Self-etch, 24 hours, permanent dentin; (G) Etch-and-rinse, six months, permanent dentin; (H) Self-etch, six months, permanent dentin. The MSBS was measured by a testing machine at a crosshead speed of 0.5 mm/minute. Data were analyzed using three-way analysis of variance (ANOVA). Results: The mean MSBS was 12.3±2.3 MPa in A, 18.8±4.1 MPa in B, 11.9±3.7 MPa in C, 16±2.9 MPa in D, 19.1±2.7 MPa in E, 22.8±4.1 MPa in F, 16.2±2.6 MPa in G, and 17.2±4.4 MPa in H. In the self-etch mode, the MSBS was significantly higher than that in the etch-and-rinse mode (P<0.001). The MSBS in permanent teeth was significantly higher than primary teeth (P<0.001). At six months, the MSBS significantly decreased in all groups (P<0.001). Conclusion: The micro-shear bond strength of Scotchbond Universal adhesive decreases over time and depends on the type of tooth and the mode of application of the adhesive.


Author(s):  
Gabriela Simões Teixeira ◽  
Gabriel Kalil Rocha Pereira ◽  
Alexandre Henrique Susin

Abstract Objectives To evaluate the effect of different artificial aging methods on the bond strength of a resin composite associated with a universal adhesive (Scotchbond Universal) used under two etching approaches (self-etch [SE] or etch-and-rinse [ER]) to enamel and dentin substrates. Materials and Methods A total of 96 noncarious human third molars were prepared and randomly divided according to three factors (n = 6): substrate (enamel and dentin), adhesive approach (SE and ER), and aging method (water storage for 24 hours, 6 months, or 1 year; subjected to 10,000, 20,000, or 30,000 thermal cycles; and sodium hypochlorite [NaOCl] storage for 1 or 5 hours). Statistical Analysis Microshear bond strength tests were conducted, and the collected data (MPa) were subjected to three-way analysis of variance (ANOVA) with post hoc Bonferroni tests (p < 0.05) and Weibull analysis. The failure pattern was also evaluated. Results Three-way ANOVA revealed that the factors “substrate” (p = 0.00) and “aging method” (p = 0.00) had a significant effect on the bond strength, but the factor “adhesive approach” did not (p = 0.84). The bond strength in the enamel group for the SE approach was negatively affected under 20,000 and 30,000 thermal cycles. Weibull presented the highest m in the NaOCl storage for the 5 hours group to enamel using the SE and to dentin using ER approaches. Adhesive/mixed failures were predominant for all groups. Conclusion Thermocycling aging (20,000 and 30,000 cycles) significantly reduced the bond strength to enamel using the SE approach. On the contrary, storage with the NaOCl method proved to increase bond strength under the evaluated conditions.


2017 ◽  
Vol 42 (3) ◽  
pp. 284-296 ◽  
Author(s):  
EC Martini ◽  
SO Parreiras ◽  
MF Gutierrez ◽  
AD Loguercio ◽  
A Reis

SUMMARY Objectives: The aim of this study was to investigate the effect of different protocols of 17% ethylene diamine tetra-acetic acid (EDTA) conditioning on the etching pattern and immediate bond strength of universal adhesives to enamel and sclerotic dentin. Methods and Materials: Forty bovine teeth with sclerotic dentin and 20 human third molars were randomly divided into eight groups resulting from the combination of the main factors surface treatment (none, two-minute EDTA conditioning manual application, 30-second EDTA manual application, 30-second EDTA sonic application) and adhesives systems (Scotchbond Universal Adhesive [SBU] and Prime & Bond Elect [PBE]). Resin-dentin and enamel-dentin bond specimens were prepared and tested under the microtensile bond strength (μTBS) and microshear bond strength (μSBS) tests, respectively. The etching pattern produced on the unground enamel and the sclerotic dentin surfaces under the different protocols and adhesive systems was evaluated under scanning electron microscopy. Results: For enamel, only the main factor adhesive was significant (p&lt;0.0001), with SBU showing the highest μSBS. In sclerotic dentin, the lowest mean was observed for the group without EDTA application and the highest mean in the group with EDTA application with the sonic device for 30 seconds. Regardless of the EDTA protocol, the highest means of μTBS were observed for SBU (p&lt;0.05). Conclusions: EDTA conditioning improves the bonding performance of universal adhesives in the self-etch mode on sclerotic dentin, mainly when applied for 30 seconds with the aid of a sonic device. EDTA pretreatment also improves the retentive etching pattern of enamel, but it does not result in higher enamel bond strength.


Author(s):  
Sara Valizadeh ◽  
Aida Moradi ◽  
Mansooreh Mirazei ◽  
Hooman Amiri ◽  
Mohammad Javad Kharazifard

Objectives: The aim of this study was to compare the microshear bond strength (µSBS) of various adhesive systems to dentin. Materials and Methods: In this in vitro experimental study, 60 sound human third molars were divided into four groups. Dentin discs were prepared of middle-third dentin measuring 4 mm in diameter and 2 mm in thickness. Dentin surfaces were bonded with one of the four types of adhesives: (A) Single Bond (3M ESPE), Scotchbond Universal (3M ESPE) in etch and rinse (B) and self-etch (C) modes and (D) Clearfil SE Bond (Kuraray Noritake Dental). After the application of adhesive systems according to the manufacturers’ instructions, composite cylinders (Vit-l-escence) were bonded to dentin surfaces. The μSBS test was performed using a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed with one-way ANOVA and Tukey’s test (α=0.05). Results: The µSBS was the highest in self-etch Scotchbond Universal (15.8±6.08 MPa) followed by Clearfil SE Bond (15.24±4.6 MPa), etch and rinse Scotchbond Universal (11.68±4.07MPa) and Single Bond (11.24±3.74 MPa). A significant difference was only found between Single Bond and etch and rinse Scotchbond Universal groups (P=0.04). Conclusion: Based on the results of this study, application of Scotchbond Universal in self-etch mode provides a reliable bond to dentin.


Author(s):  
Sara Valizadeh ◽  
Aida Moradi ◽  
Mansooreh Mirazei ◽  
Hooman Amiri ◽  
Mohammad Javad Kharazifard

Objectives: The aim of this study was to compare the microshear bond strength (µSBS) of various adhesive systems to dentin. Materials and Methods: In this in vitro experimental study, 60 sound human third molars were divided into four groups. Dentin discs were prepared of middle-third dentin measuring 4 mm in diameter and 2 mm in thickness. Dentin surfaces were bonded with one of the four types of adhesives: (A) Single Bond (3M ESPE), Scotchbond Universal (3M ESPE) in etch and rinse (B) and self-etch (C) modes and (D) Clearfil SE Bond (Kuraray Noritake Dental). After the application of adhesive systems according to the manufacturers’ instructions, composite cylinders (Vit-l-escence) were bonded to dentin surfaces. The μSBS test was performed using a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed with one-way ANOVA and Tukey’s test (α=0.05). Results: The µSBS was the highest in self-etch Scotchbond Universal (15.8±6.08 MPa) followed by Clearfil SE Bond (15.24±4.6 MPa), etch and rinse Scotchbond Universal (11.68±4.07MPa) and Single Bond (11.24±3.74 MPa). A significant difference was only found between Single Bond and etch and rinse Scotchbond Universal groups (P=0.04). Conclusion: Based on the results of this study, application of Scotchbond Universal in self-etch mode provides a reliable bond to dentin.


2021 ◽  
Vol 15 (2) ◽  
pp. 82-86
Author(s):  
Mahmoud Bahari ◽  
Siavash Savadi Oskoee ◽  
Mohammad Esmaeel Ebrahimi Chaharom ◽  
Nasim Molayi

Background. Contamination of dentin surface is one of the common problems in restorative dentistry. The aim was to investigate the effects of different surface contaminators on the dentin shear bond strength (SBS) of universal adhesive system (UAS) applied in etch-and-rinse (ER) and self-etch (SE) strategies. Methods. One hundred forty-four maxillary anterior sound human teeth were divided into six groups based on the types of surface contaminators: no surface contaminator (control) and experimental groups contaminated with blood, saliva, aluminium chloride (ALC), ferric sulphate (FS), and caries disclosing agent (CDA). Then, each group was further subdivided into two, based on the application strategy of UAS (ER and SE). After applying the adhesive according to the manufacturer’s instructions, and bonding cylindrical composite samples, the SBS was measured. The data were analysed using two-way ANOVA, Tukey’s HSD test and t test (P<0.05). Results. The SBS in all contaminated groups, except for CDA, was significantly lower in both ER and SE strategies compared to control group (P<0.05). A comparison between the application strategies revealed that ER and SE were only significantly different in the FS contaminated group (P<0.05). Conclusion. All tested contaminators, except CDA, significantly decreased SBS of UAS in both ER and SE strategies.


2017 ◽  
Vol 41 (3) ◽  
pp. 214-218 ◽  
Author(s):  
Tathiane Larissa Lenzi ◽  
Fabio Zovico Maxnuck Soares ◽  
Rachel de Oliveira Rocha

Objective: To evaluate the effect of bonding strategy on microtensile bond strength (μTBS) of a new universal adhesive system to primary tooth dentin. Study design: Flat dentin surfaces from 25 primary molars were assigned to 5 groups according to the adhesive and bonding approach: Adper Single Bond 2 (two-step etch-and-rinse adhesive) and Clearfil SE Bond (two-step self-etch system), as controls; Scotchbond Universal Adhesive–self-etch, dry or wet-bonding etch-and-rinse strategies. Composite buildups were constructed and the teeth were sectioned to obtain bonded sticks (0.8 mm2) to be tested under tension at 1mm/min. The μTBS means were analyzed by one-way ANOVA and Tukey's tests (α = 0.05). Failure mode was evaluated using a stereomicroscope (400×). Results: Universal adhesive applied following both dry and wet-bonding etch-and-rinse strategies showed similar bond strength compared with control adhesive systems. Self-etch approach resulted in the lowest μTBS values. For all groups, adhesive/mixed failure prevailed. The percentage of premature debonded specimens was higher when the universal adhesive was used as self-etch mode. Conclusion: The universal adhesive does not share the same versatility of being used in the etch-and-rinse and self-etch approaches; however, the use of the new adhesive following either wet or dry-bonding may be a suitable option as alternative to two-step etch-and-rinse adhesive protocol.


Author(s):  
Omnia M. Sami ◽  
Essam A. Naguib ◽  
Rasha H. Afifi ◽  
Shaymaa M. Nagi

Abstract Objective Bonding to different dentin substrates influences resin composite restoration outcomes. This study investigated the influence of different adhesion protocols on the shear bond strength of universal adhesive systems to sound and artificial caries-affected dentin (CAD). Materials and Methods Occlusal enamel of 80 premolars were wet grinded to obtain flat midcoronal dentin. Specimens were equally divided according to the substrate condition: sound and CAD by subjecting to pH-cycling for 14 days. Each dentin substrate was bonded with the adhesive systems used in this study: Single Bond universal adhesive or Prime&Bond universal (applied either in etch-and-rinse or self-etch adhesion protocol). Adhesive systems were utilized according to manufacturers’ instructions, then resin composite was built up. Specimens were tested for shear bond strength. The data were analyzed by three-way analysis of variance, and failure modes were determined using stereomicroscope. Results There was no statistically significant difference between the two tested adhesive systems on artificially created CAD with different adhesion protocols. On sound dentin, Single Bond universal, either in the etch-and-rinse or self-etch adhesion protocols, revealed higher statistically significant shear bond strength mean values compared with CAD. Conclusion Single Bond universal adhesive in an etch-and-rinse adhesion protocol improved only bonding to sound dentin, while no added positive effect for the etching step with Prime&Bond universal adhesive was found when bonded to both sound and CAD substrates. The influence of CAD on the performance of the universal adhesives was material-dependent.


Sign in / Sign up

Export Citation Format

Share Document