scholarly journals Effect of loading on the microtensile bond strength and microleakage of a self-etching and etch-and-rinse adhesive in direct class II MOD composite restorations in vitro

2012 ◽  
Vol 31 (6) ◽  
pp. 924-932 ◽  
Author(s):  
Theodora BRAVIS ◽  
Peter PILECKI ◽  
Ron F. WILSON ◽  
Michael FENLON ◽  
Timothy F. WATSON ◽  
...  
2020 ◽  
Vol 14 (04) ◽  
pp. 644-650
Author(s):  
Manuel Salvador Urcuyo Alvarado ◽  
Diana María Escobar García ◽  
Amaury de Jesús Pozos Guillén ◽  
Juan Carlos Flores Arriaga ◽  
Gabriel Fernando Romo Ramírez ◽  
...  

Abstract Objective Preheated resins (PR) are considered a cementing agent option for indirect adhesive restorations of composite inlays and onlays. The objective of this in vitro study was to evaluate the marginal sealing, adhesive interface, and microtensile bond strength of indirect adhesive restorations of composites in terms of dentin cemented with PR. Materials and Methods Standardized Class II preparations were performed on 30 extracted human premolars, impressions were taken, and indirect composite restorations were manufactured. In total, 15 restorations were cemented with PR (ENA HRi, SYNCA), and 15 restorations were cemented with self-adhesive resinous cement (RC) (Relyx U200, 3M ESPE), followed by a thermocycling regime. After that, these were segmented sagittally and longitudinally to evaluate the marginal sealing and the adhesive interface with scanning electron microscopy and confocal microscopy. Microtensile bond strength was assessed with a mechanical device (TA. XT Plus C, Stable Micro System). Statistical analysis Statistical analysis was conducted using the two-sample Student’s t-test. Results The results showed that there is no statistically significant difference in the degree of microfiltration using PR or RC; however, microtensile bond strength is greater when the restoration is cemented with RC (278.75 N/cm3) than with PR (144.49 N/cm3), and better adjustment and sealing were observed for composite restorations with PR. Conclusion PR comprise an alternative cementing agent for indirect composite restorations in Class II cavities in premolars.


2016 ◽  
Vol 27 (5) ◽  
pp. 532-536 ◽  
Author(s):  
Marina Studart Alencar ◽  
◽  
Juliana Fraga Soares Bombonatti ◽  
Rafael Massunari Maenosono ◽  
Ana Flávia Soares ◽  
...  

Abstract This in vitro study evaluated the effect of sodium bicarbonate and sodium ascorbate on the microtensile bond strength of an etch-and-rinse system to bleached bovine enamel. Sixty bovine enamel blocks (4x4 mm) were flattened and randomly allocated into 5 groups: G1 (negative control): without treatment; G2 (positive control): bleached with 35% hydrogen peroxide (HP); G3: bleached and stored for 7 days in artificial saliva before restorative procedures; G4: bleached and treated with 10% sodium bicarbonate solution for 5 min; G5: bleached and treated with 10% sodium ascorbate hydrogel for 15 min. HP gel was applied twice (20 min each, except in G1) and the adhesive restorations were performed. After 24 h, the specimens were sectioned into sticks and submitted to microtensile bond strength testing with a crosshead speed of 0.5 mm/min (n=12). As a complementary visual observation, the enamel surfaces of the G1 and G2 specimens were evaluated with scanning electron microscopy. Data were analyzed by one-way ANOVA (p<0.05). The means (standard deviation) were: G1: 24.22±7.74; G2: 18.29±5.88; G3: 40.88±7.95; G4: 19.95±5.67 and G5: 24.43±6.43. Adhesive failures were predominant in all groups. The comparison between the treatments indicates that waiting 7 days after bleaching is still the most effective approach. When this waiting period is not possible, application of sodium ascorbate or sodium bicarbonate seems to be a good alternative. Therefore, the practicality of obtaining sodium bicarbonate in the bleaching kits and its higher stability enables its clinical use.


2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Michele Tepedino ◽  
Maciej Iancu Potrubacz ◽  
Antonella Imperiale ◽  
Claudio Chimenti ◽  
Mario Capogreco ◽  
...  

The aim of the present study was to in vitro evaluate the effect of dentin conditioning with hydroabrasion on the microtensile bond strengths of three adhesive systems, compared to the standard etch-and-rinse technique. Sixty extracted human third molars were collected, and their midcoronal occlusal dentin was used for the microtensile bond strength test. Teeth were randomly assigned to three groups according to the adhesive system used: ExciTE F DSC, ENA Bond, and Scotchbond Universal. Specimens from each group were further divided into four subgroups: control specimens were treated with standard adhesive procedures; hydroabraded (HA) specimens were subjected to preventive hydroabrasion with three different intensity levels. After bonding procedures, composite crowns were incrementally built up. After thermocycling, specimens were subsequently sectioned into 1 × 1 mm sticks, and microtensile bond strengths were measured. Data were statistically analyzed. Failure mode analysis was performed. There were no significant differences in terms of bond strength between standard adhesion protocols and adhesion with HA preconditionings. On the other hand, the type of adhesive used had a significant effect on the tensile bond strength. Subgroups treated with hydroabrasion at higher intensity showed a slightly increased frequency of cohesive fractures. In conclusion, hydroabrasion can be used for dentin cavity preparation or finishing, since it does not seem to affect the bonding effectiveness.


2017 ◽  
Vol 28 (4) ◽  
pp. 474-481 ◽  
Author(s):  
Mário Alexandre Coelho Sinhoreti ◽  
Eveline Freitas Soares ◽  
Gabriel Flores Abuna ◽  
Lourenço Correr Sobrinho ◽  
Jean-François Roulet ◽  
...  

Abstract The aim of this study was to evaluate microtensile bond strength (µTBS) of self-etch and etch-and-rinse adhesives systems compared in different dentin regions (central-CD or proximal-PD) in a class II cavity configuration. A class II (mesial-oclusal-distal) cavity configuration was simulated on 20 extracted human third-molars (4 mm wide/3 mm deep). Etch-and-rinse adhesive (Scotchbond Multi Purpose, n=5, SBMP and Optibond FL, n=5, OPFL) and self-etch adhesives (Clearfil SE Bond, n=5, CSE and Optibond XTR, n=5, OPXTR) were applied. Class II restorations were performed by incremental technique and photo-activated (Bluephase/G2). Samples were sectioned to beam shape (1 mm² cross-section), placed on Geraldeli’s device for µTBS test (0.5 mm/min cross-head speed). Fracture patterns were analyzed on stereomicroscope and classified as cohesive-resin, adhesive, mixed/resin or mixed/dentin. Samples (n=4) were prepared for scanning electron microscope observation. Data were submitted to one-way ANOVA with Split-Plot arrangement and Tukey’s test (α=0.05). There were no statistically significant differences among SBMP, OPFL, CSE and OPXTR on CD (p>0.05). However, on PD for SBMP and OPFL, µTBS values were significantly lower compared to CSE and OPXTR (p<0.05). In all groups, mixed failure pattern was more frequently observed, except for SBMP/CD (adhesive). In class II type cavity configuration, PD location negatively influenced bond strength of etch-and-rinse adhesive systems. Opposite to self-etching adhesives, which presented higher bond strength values compared to etch-and-rinse adhesives in PD.


2006 ◽  
Vol 137 (10) ◽  
pp. 1414-1418 ◽  
Author(s):  
John H. Purk ◽  
Matthew Healy ◽  
Vladimir Dusevich ◽  
Alan Glaros ◽  
J. David Eick

2011 ◽  
Vol 36 (2) ◽  
pp. 213-221 ◽  
Author(s):  
S Kasraei ◽  
M Azarsina ◽  
S Majidi

Clinical Relevance The use of resin-modified glass ionomers as cavity liners in the closed-sandwich technique reduced microleakage in Class II composite restorations.


2019 ◽  
Vol 18 ◽  
pp. e191638
Author(s):  
Renally Bezerra Wanderley Lima ◽  
Maria Luiza Pontual ◽  
Venâncio Fernandes Dantas ◽  
Sônia Saeger Meireles ◽  
Ana Karina Maciel Andrade ◽  
...  

Aim: The aim of this study is to evaluate the effect of radiotherapy on the bond strength of resin-based composite restorations to dentin, performed either 24 h or 1 year before or after radiation. Methods: Ninety-six posterior teeth were randomly distributed into the following groups: IB (n = 16), irradiated teeth were restored 1 year after x-ray application; NB (n = 16), not irradiated teeth were stored for 1 year and then restored. IA (n = 32), teeth were restored and irradiated at 24 h or 1 year after the restoration. NA (n = 32), teeth were restored, not irradiated, and tested as IA. Eight samples from each group were randomly assigned to either the three-step or two-step etch-and rinse adhesive system procedure. The irradiated specimens were subjected to 60 Gy of x-ray radiation fractionally. The restored teeth were vertically sectioned, and 1-mm2 resin–dentin sticks were obtained and submitted to the microtensile bond strength test. The bond strength data were analyzed by two-way analysis of variance (ANOVA) followed by Tukey’s test (p < 0.05). Failure modes were examined by optical microscopy and scanning electron microscopy. Results: The IB group showed lower bond strength values compared to the NB group. The bond strength values between the adhesive systems were not statistically different. Conclusion: The application of radiation dose decreased the bond strength of the adhesive restorations to dentin when the bonding procedure was conducted 1 year after in vitro radiotherapy.