scholarly journals Geophysical Investigation of Subsurface Water of Erunmu and its Environs, Southwestern Nigeria Using Electrical Resistivity Method

2015 ◽  
Vol 15 (5) ◽  
pp. 741-751 ◽  
Author(s):  
Lukuman Abudulawal ◽  
Sikiru A. Amidu ◽  
Kasim A. Apanpa ◽  
Olusola A. Adeagbo ◽  
Olukole A. Akinbiyi
2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Olaseeni Olayiwola ◽  
Fagbemigun Tokunbo ◽  
Ojo Bosede ◽  
Amosun Joel ◽  
Oyebamiji Ajibola

Abstract An appraisal of the groundwater vulnerability to contamination risk at Adebayo in Ado-Ekiti, Southwestern Nigeria, was carried out using the electrical resistivity method of geophysical prospecting. Two traverses of length 100 m each were established for both vertical electrical sounding (VES) and dipole-dipole. Six (6) Vertical Electrical Sounding (VES) and 2-D dipole-dipole profiling techniques of the electrical resistivity method were adopted for the geophysical investigation. The results show variations in resistivity values, depicting four to five geologic layers: the topsoil, laterite, weathered layer, fractured, and the fresh basement. It was observed from the correlation of the geoelectric section and 2-D resistivity image along traverse 1 (TR1) that the groundwater in the study area flows towards the southwestern part, and the fractured basement serves as a migration pathway to the diesel oil in the same direction as groundwater flow. The fractured basement (Well 2) with no lateritic cover has higher resistivity values compare to the fracture zone that was found directly under the mast which was overlain by the laterite. Comparing the resistivity values of Well 1 and 2, Well 2 that was drilled into the fractured basement has more traces of the contaminant than Well 1.


2018 ◽  
Vol 65 (2) ◽  
pp. 103-114 ◽  
Author(s):  
Oluseun Adetola Sanuade ◽  
Abayomi Adesola Olaojo ◽  
Adesoji Olumayowa Akanji ◽  
Michael Adeyinka Oladunjoye ◽  
Gabriel E. Omolaiye

Abstract This geophysical study was carried out to determine the occurrence of phosphate nodules in the Oshoshun Formation of the Dahomey Basin, Southwestern Nigeria. The electrical resistivity method, comprising 1D vertical electrical sounding (VES; using Schlumberger array) and 2D geoelectrical imaging (using Wenner array), was used to determine the nature and depth of occurrence of the phosphate nodules. Six profile lines were established within the study area, and inverted sections were generated from the apparent resistivity data using DIPRO inversion algorithm. Five VES points were also acquired in the study area, and Win- Resist programme was used to process and interpret the field resistivity data. Four pits were dug along the profiles to verify the interpreted results. The results obtained by both techniques reveal similar geoelectric units: the top soil, clay, clayey sand and clay at different depths. These layers host pockets of phosphate nodules (78-≥651 Ωm) with varying thicknesses. The strong correlation between the lithology profiles obtained from the pits and the interpreted results of the inverted apparent resistivity sections demonstrates the efficacy of the electrical resistivity method in characterising phosphate occurrence within the formation.


2021 ◽  
Vol 1 (2) ◽  
pp. 49-62
Author(s):  
Babatunde A. Adebo ◽  
Oladipupo Emmanuel Makinde ◽  
Stephen Olubusola Ilugbo

This research was carried out within Institute of Agriculture Research and Training Moor Plantation Ibadan, Southwestern Nigeria, with the aim to ascertain suitability of the proposed site for building construction and usage. The geophysical investigation involved three electrical resistivity techniques; Vertical Electrical Sounding (VES) using the Schlumberger configuration, 2D ERT and 2-D electrical imaging using Dipole-dipole electrode configuration. Two traverses were established E–W direction cutting across geologic strike with a distance of 80 m and of varying inter-traverse spacing. Eight (8) VES stations were occupied covering the entire study area for layer stratification and geoelectric parameters. The results were qualitatively and quantitatively interpreted and are presented as sounding curves and geoelectric sections. The 2-D imaging gave information on the subsurface characteristic in the area with generally low apparent resistivity indicating low competence material. The results obtained from the VES delineate three geoelectric units which comprise of the topsoil, weathered layer and fresh basement. The results from the VES were used to determine the second order parameters. The entire results correlate well with one another showing that all the techniques used were complemented. This study has further justified the need for geophysical site investigation as pre-condition before any construction to avoid problems of differential settlement. In determining of foundation material, topography elevation, clay content and the depth of weak zones should be put into consideration, since the depth of the weak zone is appreciably high.


Sign in / Sign up

Export Citation Format

Share Document