Evaluation of rapid test kits for quantification of deoxynivalenol in naturally contaminated oats and wheat

2012 ◽  
Vol 5 (4) ◽  
pp. 339-350 ◽  
Author(s):  
H.U. Aamot ◽  
I.S. Hofgaard ◽  
G. Brodal ◽  
O. Elen ◽  
M. Jestoi ◽  
...  

The aim of this study was to evaluate the performance of rapid test kits for analysis of deoxynivalenol (DON), a mycotoxin commonly found in small-grain cereals. Concentrations of DON and its acetylated derivative 3-acetyldeoxynivalenol (3-ADON) were analysed in naturally contaminated wheat (n=56) and oats (n=81) using two enzyme-linked immunosorbent assays, i.e. Ridascreen® DON (‘Standard ELISA’) and Ridascreen® FAST DON (‘Fast ELISA’), and two lateral flow devices, i.e. Rida® QUICK DON (‘Quick LFD’) and Rosa® DON (‘Rosa LFD’). Analysis by the LC-MS/MS reference method showed a median DON + 3-ADON concentration of 1,168 μg/kg (90th percentile 3,264 μg/kg) in wheat and 2,250 μg/kg (90th percentile of 9,008 μg/kg) in oats. Rosa LFD offered the best reliability, achieving detection that was stable across toxin levels in both matrices. In addition, Rosa LFD had the highest accuracy (i.e. proportion of correct results) at a DON level of 1,250 μg/kg in wheat (0.83) and 8,000 μg/kg in oats (0.96). Standard ELISA achieved the highest accuracy at a DON level of 1,750 μg/kg in oats (0.85). Detection by Quick LFD in wheat and Fast ELISA in both wheat and oats differed significantly among toxin levels (P≤0.05), with recoveries outside European Union requirements (70-120%) in some cases. The correlation with results from LC-MS/MS analysis in oats was best for Rosa LFD (R2=0.79). In wheat, however the correlation was best for Fast ELISA (R2=0.81). Rosa LFD was regarded as well-suited for on-site detection. Standard ELISA allowed simultaneous testing of several samples and achieved detection that was stable across toxin levels in both matrices, making it a useful alternative in laboratories. To our knowledge, this is the first report describing the performance of rapid test kits for detection of DON in naturally contaminated oats.

2013 ◽  
Vol 6 (1) ◽  
pp. 31-41 ◽  
Author(s):  
H.U. Aamot ◽  
I.S. Hofgaard ◽  
G. Brodal ◽  
O. Elen ◽  
B. Holen ◽  
...  

The aim of this study was to evaluate the performance and usefulness of three rapid test kits for analysis of HT-2 and T-2 toxins (HT-2 and T-2), two of the most potent trichothecenes commonly found in European oats. Concentrations of these two toxins combined (HT-2+T-2) were analysed in naturally contaminated oat samples (n=68) using the following test kits: Ridascreen® FAST T-2 Toxin (‘Fast ELISA’), DRAFT Ridascreen® HT-2/T-2 (‘Standard ELISA’, not commercially available), and the lateral flow device ROSA® HT-2-T-2 (‘Rosa LFD’). Mycotoxin analysis by LC-MS/MS was used as a reference method. Rosa LFD offered the best reliability, achieving detection that was stable across toxin levels, whereas detection by both ELISA kits differed significantly among toxin levels (P<0.01). The kits were also evaluated regarding agreement with the reference method (measured as Cohen's kappa) at a HT-2+T-2 concentration of 1000 μg/kg in naturally contaminated oats. Agreement was greatest for Rosa LFD (89.2%), intermediate for Standard ELISA (66.8%), and lowest for Fast ELISA (62.2%). Rosa LFD showed cross-reaction of 100% with both T-2 and HT-2. For the ELISA kits, cross-reactions were 100% with T-2 but below 100% with HT-2. Therefore, to estimate the sum of HT-2 and T-2 in an oat sample, it was necessary to re-calculate the data from both ELISA kits according to the known cross-reaction of each kit with HT-2 and the concentration ratio of HT-2 to T-2 in Norwegian oats. Rosa LFD had the highest correlation with LC-MS/MS (R2=0.94), and the corresponding R2 values for Fast and Standard ELISA were 0.61 and 0.83, respectively. Rosa LFD was well suited for on-site detection. Standard ELISA allows simultaneous testing of several samples that are useful for centralised laboratories.


2021 ◽  
Author(s):  
Hayley E Jones ◽  
Ranya Mulchandani ◽  
Sian Taylor-Phillips ◽  
A E Ades ◽  
Justin Shute ◽  
...  

AbstractBackgroundSARS-CoV-2 antibody tests are used for population surveillance and might have a future role in individual risk assessment. Lateral flow immunoassays (LFIAs) can deliver results rapidly and at scale, but have widely varying accuracy.MethodsIn a laboratory setting, we performed head-to-head comparisons of four LFIAs: the Rapid Test Consortium’s AbC-19™ Rapid Test, OrientGene COVID IgG/IgM Rapid Test Cassette, SureScreen COVID-19 Rapid Test Cassette, and Biomerica COVID-19 IgG/IgM Rapid Test. We analysed blood samples from 2,847 key workers and 1,995 pre-pandemic blood donors with all four devices.FindingsWe observed a clear trade-off between sensitivity and specificity: the IgG band of the SureScreen device and the AbC-19™ device had higher specificities but OrientGene and Biomerica higher sensitivities. Based on analysis of pre-pandemic samples, SureScreen IgG band had the highest specificity (98.9%, 95% confidence interval 98.3 to 99.3%), which translated to the highest positive predictive value across any pre-test probability: for example, 95.1% (95%CI 92.6, 96.8%) at 20% pre-test probability. All four devices showed higher sensitivity at higher antibody concentrations (“spectrum effects”), but the extent of this varied by device.InterpretationThe estimates of sensitivity and specificity can be used to adjust for test error rates when using these devices to estimate the prevalence of antibody. If tests were used to determine whether an individual has SARS-CoV-2 antibodies, in an example scenario in which 20% of individuals have antibodies we estimate around 5% of positive results on the most specific device would be false positives.FundingPublic Health England.Research in contextEvidence before this studyWe searched for evidence on the accuracy of the four devices compared in this study: OrientGene COVID IgG/IgM Rapid Test Cassette, SureScreen COVID-19™ Rapid Test Cassette, Biomerica COVID-19 IgG/IgM Rapid Test and the UK Rapid Test Consortium’s AbC-19™ Rapid Test. We searched Ovid MEDLINE (In-Process & Other Non-Indexed Citations and Daily), PubMed, MedRxiv/BioRxiv and Google Scholar from January 2020 to 16th January 2021. Search terms included device names AND ((SARS-CoV-2) OR (covid)). Of 303 records assessed, data were extracted from 24 studies: 18 reporting on the accuracy of the OrientGene device, 7 SureScreen, 2 AbC-19™ and 1 Biomerica. Only three studies compared the accuracy of two or more of the four devices. With the exception of our previous report on the accuracy of the AbC-19™ device, which the current manuscript builds upon, sample size ranged from 7 to 684. For details, see Supplementary Materials.The largest study compared OrientGene, SureScreen and Biomerica. SureScreen was estimated to have the highest specificity (99.8%, 95% CI 98.9 to 100%) and OrientGene the highest sensitivity (92.6%), but with uncertainty about the latter result due to small sample sizes. The other two comparative studies were small (n = 65, n = 67) and therefore provide very uncertain results.We previously observed spectrum effects for the AbC-19™ device, such that sensitivity is upwardly biased if estimated only from PCR-confirmed cases. The vast majority of previous studies estimated sensitivity in this way.Added value of this studyWe performed a large scale (n = 4,842), head-to-head laboratory-based evaluation and comparison of four lateral flow devices, which were selected for evaluation by the UK Department of Health and Social Care’s New Tests Advisory Group, on the basis of a survey of test and performance data available. We evaluated the performance of diagnosis based on both IgG and IgM bands, and the IgG band alone. We found a clear trade-off between sensitivity and specificity across devices, with the SureScreen and AbC-19™ devices being more specific and OrientGene and Biomerica more sensitive. Based on analysis of 1,995 pre-pandemic blood samples, we are 99% confident that SureScreen (IgG band reading) has the highest specificity of the four devices (98.9%, 95% CI 98.3, 99.3%).We found evidence that all four devices have reduced sensitivity at lower antibody indices, i.e. spectrum effects. However, the extent of this varies by device and appears to be less for other devices than for AbC-19.Our estimates of sensitivity and specificity are likely to be higher than would be observed in real use of these devices, as they were based on majority readings of three trained laboratory personnel.Implications of all the available evidenceWhen used in epidemiological studies of antibody prevalence, the estimates of sensitivity and specificity provided in this study can be used to adjust for test errors. Increased precision in error rates will translate to increased precision in seroprevalence estimates. If lateral flow devices were used for individual risk assessment, devices with maximum specificity would be preferable. However, if, for an example, 20% of the tested population had antibodies, we estimate that around 1 in 20 positive results on the most specific device would be incorrect.


2015 ◽  
Vol 864 ◽  
pp. 48-54 ◽  
Author(s):  
Eleni A. Sapountzi ◽  
Sotirios S. Tragoulias ◽  
Despina P. Kalogianni ◽  
Penelope C. Ioannou ◽  
Theodore K. Christopoulos

2021 ◽  
Author(s):  
Uffe Vest Schneider ◽  
Jenny Dahl Knudsen ◽  
Anders Koch ◽  
Nikolai Søren Kirkby ◽  
Jan Gorm Lisby

BACKGROUND The SARS-CoV-2 pandemic has resulted in an unprecedented level of world-wide testing for epidemiologic and diagnostic purposes, and due to the extreme need for tests, the gold standard reverse transcription polymerase chain reaction (RT-qPCR) testing capacity has been unable to meet the overall global testing demand. Consequently, although current literature has shown the sensitivity of rapid antigen tests (RATs) to be inferior to RT-qPCR, RATs have been implemented on a large scale without solid data on performance. OBJECTIVE This study will compare analytical and clinical sensitivities and specificities of 50 lateral flow or laboratory based RATs and three Strand Invasion Based Amplification (SIBA)-rt-PCR tests from 30 manufacturers to RT-qPCR on samples obtained from the deep oropharynx. In addition, the study will compare sensitivities and specificities of the included RATs as well as RT-qPCR on clinical samples obtained from the deep oropharynx, anterior nasal cavity, saliva, deep nasopharynx and expired air to RT-qPCR from deep oropharyngeal samples. METHODS In the prospective part of the study, 200 individuals found SARS-CoV-2 positive and 200 individuals found SARS-CoV-2 negative by routine RT-qPCR testing will be re-tested with each RAT applying RT-qPCR as the reference method. In the retrospective part of the study, 304 deep oropharyngeal cavity swabs divided into four groups based on RT-qPCR Cq levels will be tested by each RAT. RESULTS The results will be reported in several manuscripts with different aims. The first manuscript will report retrospective (analytical sensitivity, overall and stratified into different Cq range groups) and prospective (clinical sensitivity) data for RATs with RT-qPCR results as the reference method. The second manuscript will report results for RAT based on anatomical sampling location. The third manuscript will compare different anatomical sampling locations by RT-qPCR testing. The fourth manuscript will focus on RATs that rely on central laboratory testing. Test from four different manufactures will be compared for analytical performance data on retrospective deep oropharyngeal swab samples. The fifth manuscript will report the results of four RATs applied both as professional use and as self-test. The last manuscript will report the results from two breath tests participating in the study. Comparison of sensitivity and specificity between RATs will be done using McNemar for paired samples and chi-squared test for unpaired samples. Comparison of PPV and NPV between RATs will be done by bootstrap test. 95 % confidence intervals for sensitivity, specificity, positive predictive value and negative predictive value are calculated as bootstrap confidence intervals CONCLUSIONS The study will compare the sensitivities of a large number of RATs for SARS-CoV-2 compared to RT-qPCR and will address whether lateral flow based RATs test differ significantly from laboratory based RATS. The anatomical test location for both RAT and RT-qPCR will be compared. CLINICALTRIAL ClinicalTrials.gov NCT04913116


Author(s):  
Fadi Haddad ◽  
Christopher C Lamb ◽  
Ravina Kullar ◽  
George Sakoulas

Background: Covid-19 remains a pandemic with multiple challenges to confirm patient infectivity: lack of sufficient tests, accurate results, validated quality, and timeliness of results. We hypothesize that a rapid 15-minute Point-Of-Care serological test to evaluate past infection complements diagnostic testing for Covid-19 and significantly enhances testing availability. Method: A three arm observational study at Sharp Healthcare, San Diego, California was conducted using the Clungene® lateral flow immunoassay (LFI) and compared with the Cobas® Roche RT PCR results. Arm 1: Thirty-five (35) subjects with confirmed Covid-19 using RT-PCR were tested twice: prior to 14 days following symptom onset and once between 12 and 70 days. Arm 2: Thirty (30) subjects with confirmed Covid-19 using RT-PCR were tested 12-70 days post symptom onset. Arm 3: Thirty (30) subjects with a negative RT-PCR for Covid-19 were tested 1-10 days following the RT-PCR test date. Results: Specificity of confirmed negative Covid-19 by RT-PCR was 100% (95% CI, 88.4%-100.0%); meaning there was 100% negative positive agreement between the RT-PCR and the Clungene® serological test results. Covid-19 subjects tested prior to day 7 symptom onset were antibody negative. In subjects 7-12 days following symptom onset with a confirmed positive Covid-19 by RT-PCR, the combined sensitivity of IgM and IgG was 58.6% (95% CI, 38.9%-76.5%). In subjects 13-70 days following symptom onset with a confirmed positive Covid-19 by RT-PCR the combined sensitivity of IgM and IgG was 90.5% (95% CI, 80.4%-96.4%). Conclusion: The Clungene® lateral flow immunoassay (LFI) is a useful tool to confirm individuals with an adaptive immune response to SARS-CoV-2 indicating past infection. Providing Point-Of-Care results within 15 minutes without any laboratory instrumentation or specialized software has an added value of increasing test availability to patients who have been symptomatic for more than one week to confirm past infection. Performance characteristics are optimal after 13 days with a sensitivity and specificity of 90% and 100%, respectively.


Author(s):  
Yaniv Lustig ◽  
Shlomit Keler ◽  
Rachel Kolodny ◽  
Nir Ben-Tal ◽  
Danit Atias-Varon ◽  
...  

Abstract Background Coronavirus disease 2019 (COVID-19) and dengue fever are difficult to distinguish given shared clinical and laboratory features. Failing to consider COVID-19 due to false-positive dengue serology can have serious implications. We aimed to assess this possible cross-reactivity. Methods We analyzed clinical data and serum samples from 55 individuals with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. To assess dengue serology status, we used dengue-specific antibodies by means of lateral-flow rapid test, as well as enzyme-linked immunosorbent assay (ELISA). Additionally, we tested SARS-CoV-2 serology status in patients with dengue and performed in-silico protein structural analysis to identify epitope similarities. Results Using the dengue lateral-flow rapid test we detected 12 positive cases out of the 55 (21.8%) COVID-19 patients versus zero positive cases in a control group of 70 healthy individuals (P = 2.5E−5). This includes 9 cases of positive immunoglobulin M (IgM), 2 cases of positive immunoglobulin G (IgG), and 1 case of positive IgM as well as IgG antibodies. ELISA testing for dengue was positive in 2 additional subjects using envelope protein directed antibodies. Out of 95 samples obtained from patients diagnosed with dengue before September 2019, SARS-CoV-2 serology targeting the S protein was positive/equivocal in 21 (22%) (16 IgA, 5 IgG) versus 4 positives/equivocal in 102 controls (4%) (P = 1.6E−4). Subsequent in-silico analysis revealed possible similarities between SARS-CoV-2 epitopes in the HR2 domain of the spike protein and the dengue envelope protein. Conclusions Our findings support possible cross-reactivity between dengue virus and SARS-CoV-2, which can lead to false-positive dengue serology among COVID-19 patients and vice versa. This can have serious consequences for both patient care and public health.


2009 ◽  
Vol 4 (11) ◽  
pp. 1934578X0900401 ◽  
Author(s):  
Chun Ren Wang ◽  
Rong Sun ◽  
Chen Ren Ou Yang ◽  
Ye Gao Chen ◽  
Hong Chuang Song

Two new lignans, (8R,8′R)-8- hydroxy-3,4-dimethoxy-3′,4′-methylenedioxy-7-oxolignan (1) and (7′R,8′S)-3,4-methylenedioxy-3′,4′-dimethoxy -7,8-seco-7,7′-epoxylignan-7,8-dione (2), were isolated from the EtOAc extract of the fruits of Schisandra sphenanthera, along with ten known compounds. The structures of these compounds were elucidated on the basis of NMR and MS analysis. This is the first report of the occurrence of secolignans in Schisandra.


2019 ◽  
Vol 6 (Supplement_2) ◽  
pp. S654-S654
Author(s):  
Matthew Thompson ◽  
Monica L Zigman Suchsland ◽  
Victoria Lyon ◽  
Enos Kline ◽  
ShiChu Huang ◽  
...  

Abstract Background Seasonal influenza (flu) occurs annually, causing disease with substantial morbidity and mortality. Currently, flu is suspected from clinical features, but requires a laboratory test to confirm infection. No influenza tests in the United States are approved for use outside of clinical settings. We aimed to determine the accuracy of influenza self-testing using an at-home, app-guided, lateral flow assay compared with a molecular reference standard conducted at a laboratory among adults self-reporting influenza-like illness (ILI). Methods This is an observational study of individuals with self-reported ILI throughout the continental 48 United States recruited from the Flu Near You platform, online marketing, and clinics in the Seattle area. Recruitment took place from March 4 to April 26, 2019. Participants were directed to an iPhone App that determined eligibility, consent, and responses to symptom questions and risk factors. Individuals were mailed a commercially available CLIA-waived influenza lateral flow test to conduct at home, guided by the app, and returned the used test along with a second nasal swab collected in viral transport media to the research team. Influenza testing was performed by RT–PCR on the second nasal swab, as well as the residual fluid from the RDT. Accuracy of home test result (read by the participant), as well as image capture of the lateral flow test strip, were compared with the lab-based reference standard. Results To date, 1127 at-home flu tests were mailed to participants and 711 (63.1%) samples returned to the lab. There were 17 flu-positive results from the rapid diagnostic test for a flu positivity rate of 2.4%. Testing using the reference standard is currently in progress. We will share diagnostic accuracy results once testing of the reference standard is completed. Of the kits returned, 353 (49.7%)had an error recorded, which included errors in return packaging, reference standard, rapid test tube sample, or rapid test strip errors. Conclusion Overall, findings from this study will determine the accuracy of an at-home rapid diagnostic test, and inform more widely research design for evaluating smartphone-enhanced home tests for pathogens. Many samples returned to the lab had a recorded error, suggesting at-home testing requires additional feasibility testing and refinement of the current methods used. Disclosures All authors: No reported disclosures.