scholarly journals Reflex threshold of signal-to-cut-off ratios of the Elecsys anti-HCV II assay for hepatitis C virus infection

2016 ◽  
Vol 10 (09) ◽  
pp. 1031-1034 ◽  
Author(s):  
Jie Pan ◽  
Xin Li ◽  
Guowei He ◽  
Shuai Yuan ◽  
Pingfeng Feng ◽  
...  

Introduction: Fast screening tests for hepatitis C virus (HCV) antibody often give false-positive results. Signal-to-cut-off (S/Co) ratios were suggested to be used as reflex confirmation of anti-HCV. The Elecsys Anti-HCV II assay is an effective test for the detection of hepatitis C, but no S/Co cutoff has been reported. The aim of this study was to determine the S/Co ratio threshold of anti-HCV test using Elecsys Anti-HCV II screening and supplemental recombinant immunoblot assay (RIBA) test results as the gold standard. Methodology: A total of 36,341 serum samples were tested for HCV antibody using the Elecsys Anti-HCV II assay and 276 positive samples were then tested with supplemental RIBA (Mikrogen recomLine HCV IgG strip immunoassay). Receiver operation curve (ROC) analysis was used to determine the cutoff, sensitivity, and specificity of the optimal S/Co ratio. Results: The Elecsys Anti-HCV II assay was positive (S/Co ratio ≥ 1) in 288 of the 36,341 samples (0.79%). RIBA testing on 276 of these 288 positive samples showed that all but one of 44 samples with an S/Co ratio of ≥ 1 and < 10 were negative, whereas the vast majority of samples (223/232, 96.1%) with an S/Co ratio ≥ 10 were positive. ROC analysis revealed that an optimal S/Co ratio cut-off value was 12.27. Conclusions: An S/Co ratio of 12.27 obtained with the Elecsys Anti-HCV II assay could be used as reflex confirmation of anti-HCV tests.

2012 ◽  
Vol 19 (8) ◽  
pp. 1329-1331 ◽  
Author(s):  
Marco Moretti ◽  
Barbara Pieretti ◽  
Annamaria Masucci ◽  
Davide Sisti ◽  
Marco Rocchi ◽  
...  

ABSTRACTWe reviewed results from 12,800 samples tested for hepatitis C virus (HCV) antibody detection in our laboratory by screening (Ortho chemiluminescence immunoassay [CIA]) and supplemental tests (Chiron recombinant immunoblot assay [RIBA]). We found that a signal-to-cutoff (S/Co) ratio of 10.3 was, in our setting, the most efficient cutoff point to improve the diagnostic algorithm of HCV infection.


2007 ◽  
Vol 21 (1) ◽  
pp. 83-85 ◽  
Author(s):  
D. Stanković-Djordjević ◽  
G. Tasić ◽  
M. Dinić ◽  
N. Miladinović-Tasić ◽  
P. Stojanović ◽  
...  

1994 ◽  
Vol 21 (1) ◽  
pp. 133-134 ◽  
Author(s):  
Jérôme Lamoril ◽  
Françoise Lunel ◽  
Pierre Laurent-Puig ◽  
Christine Defer ◽  
Pascale Loiseau ◽  
...  

Hepatology ◽  
1995 ◽  
Vol 21 (6) ◽  
pp. 1754-1755 ◽  
Author(s):  
Pietro Andreone ◽  
Carmela Cursaro ◽  
Annagiulia Gramenzi ◽  
Maria Silvia Guidetti ◽  
Frederico Bardazzi ◽  
...  

1995 ◽  
Vol 33 (5) ◽  
pp. 1357-1359 ◽  
Author(s):  
J M Pawlotsky ◽  
F Roudot-Thoraval ◽  
C Pellet ◽  
P Aumont ◽  
F Darthuy ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document