scholarly journals Selection of the Climate Parameters for a Building Envelopes and Indoor Climate Systems Design

2017 ◽  
Vol 9 (4) ◽  
pp. 436-441
Author(s):  
Oleg Samarin ◽  
Sabina Paulauskaitė ◽  
Kęstutis Valančius ◽  
Kęstutis Čiuprinskas

The current research considers the principles of selection of the climate information needed for the building envelope and indoor climate design and adopted in Russia and some European countries. Special reference has been made to the shortcoming of methodologies that include the notion of a typical year, and the advantages of climate data sets generated via software-based designs, using pseudo-random number generators. The results of the average temperature of the coldest five-day period with various supplies were calculated using the numerical Monte-Carlo simulations, as well as the current climate data. It has been shown that there is a fundamental overlap between the statistical distribution of temperatures of both instances and the possibility of implementation a probabilistic-statistical method principle in the development of certain climate data, relative to envelopes and thermal conditions of a building. The calculated values were combined with the analytic expression of the normal law of random distribution and the correlations needed for the main parameter selection.

1995 ◽  
Vol 31 (2) ◽  
pp. 193-204 ◽  
Author(s):  
Koen Grijspeerdt ◽  
Peter Vanrolleghem ◽  
Willy Verstraete

A comparative study of several recently proposed one-dimensional sedimentation models has been made. This has been achieved by fitting these models to steady-state and dynamic concentration profiles obtained in a down-scaled secondary decanter. The models were evaluated with several a posteriori model selection criteria. Since the purpose of the modelling task is to do on-line simulations, the calculation time was used as one of the selection criteria. Finally, the practical identifiability of the models for the available data sets was also investigated. It could be concluded that the model of Takács et al. (1991) gave the most reliable results.


Author(s):  
Christian Luksch ◽  
Lukas Prost ◽  
Michael Wimmer

We present a real-time rendering technique for photometric polygonal lights. Our method uses a numerical integration technique based on a triangulation to calculate noise-free diffuse shading. We include a dynamic point in the triangulation that provides a continuous near-field illumination resembling the shape of the light emitter and its characteristics. We evaluate the accuracy of our approach with a diverse selection of photometric measurement data sets in a comprehensive benchmark framework. Furthermore, we provide an extension for specular reflection on surfaces with arbitrary roughness that facilitates the use of existing real-time shading techniques. Our technique is easy to integrate into real-time rendering systems and extends the range of possible applications with photometric area lights.


Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 860
Author(s):  
Piotr Michalak

Modern buildings with new heating, ventilation and air conditioning (HVAC) systems offer possibility to fit parameters of the indoor environment to the occupants’ requirements. The present paper describes the results of measurements performed in an office room in the first Polish passive commercial office building during four months of normal operation. They were used to calculate parameters describing thermal comfort: vertical air temperature profile, floor surface temperature, predicted mean vote (PMV) and predicted percent of dissatisfied (PPD). Obtained results confirmed good thermal conditions in the analysed room. The average temperature of the floor’s surface varied from 20.6 °C to 26.2 °C. The average vertical air temperature, calculated for working days, was from 22.5 °C to 23.1 °C. The temperature difference between the floor and 5 cm below the ceiling was from −0.9 °C to 6.3 °C. The PMV index varied from 0.52 to 1.50 indicating ‘slightly warm’ sensation, in spite of ‘neutral’ reported by employees. Also measured cooling and heating energy consumption was presented. The performed measurements confirmed the ability of thermally activated building system (TABS) to keep good thermal conditions.


Proceedings ◽  
2021 ◽  
Vol 65 (1) ◽  
pp. 29
Author(s):  
Alessandro Pracucci ◽  
Sara Magnani ◽  
Laura Vandi ◽  
Oscar Casadei ◽  
Amaia Uriarte ◽  
...  

The nearly Zero Energy building (nZEB) renovation market is currently the key feature in the construction sector. RenoZEB aims to develop a systematic approach for retrofitting by assembling different technologies in a plug and play building envelope. This paper presents the methodology used to transform the RenoZEB concept in the design system. A multi-criteria decision matrix is used for the selection of the best façade technologies within the market while the analysis of the existing building conditions allows to develop a replicable approach for designing deep retrofitting intervention through a plug&play façade. The methodology appears to be a valuable support for the selection of technologies and allows to define a design guideline for the envelope.


Buildings ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 152
Author(s):  
Karin Kompatscher ◽  
Rick P. Kramer ◽  
Bart Ankersmit ◽  
Henk L. Schellen

The majority of cultural heritage is stored in archives, libraries and museum storage spaces. To reduce degradation risks, many archives adopt the use of archival boxes, among other means, to provide the necessary climate control and comply with strict legislation requirements regarding temperature and relative air humidity. A strict ambient indoor climate is assumed to provide adequate environmental conditions near objects. Guidelines and legislation provide requirements for ambient indoor climate parameters, but often do not consider other factors that influence the near-object environment, such as the use of archival boxes, airflow distribution and archival rack placement. This study aimed to provide more insight into the relation between the ambient indoor conditions in repositories and the hygrothermal conditions surrounding the collection. Comprehensive measurements were performed in a case study archive to collect ambient, local and near-object conditions. Both measurements and computational fluid dynamics (CFD) modeling were used to research temperature/relative humidity gradients and airflow distribution with a changing rack orientation, climate control strategy and supply as well as exhaust set-up in a repository. The following conclusions are presented: (i) supplying air from one air handling unit to multiple repositories on different floors leads to small temperature differences between them. Differences in ambient and local climates are noticed; (ii) archival boxes mute and delay variations in ambient conditions as expected—however, thermal radiation from the building envelope may have a large influence on the climate conditions in a box; (iii) adopting night reduction for energy conservation results in an increased influence of the external climate, with adequate insulation, this effect should be mitigated; and (iv) the specific locations of the supply air and extraction of air resulted in a vertical gradient of temperature and insufficient mixing of air, and adequate ventilation strategies should enhance sufficient air mixing in combination with the insulation of external walls, and gradient forming should be reduced.


2017 ◽  
Vol 21 (9) ◽  
pp. 4747-4765 ◽  
Author(s):  
Clara Linés ◽  
Micha Werner ◽  
Wim Bastiaanssen

Abstract. The implementation of drought management plans contributes to reduce the wide range of adverse impacts caused by water shortage. A crucial element of the development of drought management plans is the selection of appropriate indicators and their associated thresholds to detect drought events and monitor the evolution. Drought indicators should be able to detect emerging drought processes that will lead to impacts with sufficient anticipation to allow measures to be undertaken effectively. However, in the selection of appropriate drought indicators, the connection to the final impacts is often disregarded. This paper explores the utility of remotely sensed data sets to detect early stages of drought at the river basin scale and determine how much time can be gained to inform operational land and water management practices. Six different remote sensing data sets with different spectral origins and measurement frequencies are considered, complemented by a group of classical in situ hydrologic indicators. Their predictive power to detect past drought events is tested in the Ebro Basin. Qualitative (binary information based on media records) and quantitative (crop yields) data of drought events and impacts spanning a period of 12 years are used as a benchmark in the analysis. Results show that early signs of drought impacts can be detected up to 6 months before impacts are reported in newspapers, with the best correlation–anticipation relationships for the standard precipitation index (SPI), the normalised difference vegetation index (NDVI) and evapotranspiration (ET). Soil moisture (SM) and land surface temperature (LST) offer also good anticipation but with weaker correlations, while gross primary production (GPP) presents moderate positive correlations only for some of the rain-fed areas. Although classical hydrological information from water levels and water flows provided better anticipation than remote sensing indicators in most of the areas, correlations were found to be weaker. The indicators show a consistent behaviour with respect to the different levels of crop yield in rain-fed areas among the analysed years, with SPI, NDVI and ET providing again the stronger correlations. Overall, the results confirm remote sensing products' ability to anticipate reported drought impacts and therefore appear as a useful source of information to support drought management decisions.


2021 ◽  
Vol 13 (6) ◽  
pp. 3054
Author(s):  
Renata Tubelo ◽  
Lucelia Rodrigues ◽  
Mark Gillott ◽  
May Zune

In Brazil, the delivery of homes for low-inc ome households is dictated by costs rather than performance. Issues such as the impact of climate change, affordability of operational energy use, and lack of energy security are not taken into account, even though they can severely impact the occupants. In this work, the authors evaluated the thermal performance of two affordable houses as-built and after the integration of envelope improvements. A new replicable method to evaluate the cost-effectiveness of these improvements was proposed. The case study houses comprise the most common affordable housing type delivered widely across Brazil and a proposition of a better affordable housing solution, built in Porto Alegre, southern Brazil, integrating passive design strategies to increase thermal comfort. The findings reveal a potential for improving indoor thermal conditions by up to 76% and 73%, respectively, if costs are not a concern, and 40% and 45% with a cost increase of 12% and 9% if a comfort criterion of 20–25 °C was considered. Equations to estimate costs of improvements in affordable housing were developed. The authors concluded that there is a great scope for building envelope optimisation, and that this is still possible without significant impact on budget.


Sign in / Sign up

Export Citation Format

Share Document