scholarly journals PREDICTION OF SHEAR CAPACITY OF UHPC – CONCRETE COMPOSITE STRUCTURAL MEMBERS BASED ON EXISTING CODES

2018 ◽  
Vol 24 (8) ◽  
pp. 607-618 ◽  
Author(s):  
Hor Yin ◽  
Kazutaka Shirai ◽  
Wee Teo

Reinforced concrete (RC) structural members strengthened with ultrahigh-performance concrete (UHPC) have shown excellent performance in past experimental investigations. However, methods of predicting their capacity are currently very limited. This paper presents six independent methods of predicting the shear capacity of UHPC–concrete composite members based on the application of existing design codes. Three of these methods are based on the conversion of the volume fraction of steel fibres in the UHPC in an equivalent longitudinal steel ratio. The other three methods involve the computation of the shear strength as a sum of the contributions to the shear strength by the RC member and the UHPC layer, each of which is independently calculated. It was demonstrated that the proposed methods based on existing design codes are able to predict the strength of UHPC–concrete composite members with reasonable accuracy.

2006 ◽  
Vol 33 (6) ◽  
pp. 726-734 ◽  
Author(s):  
Fariborz Majdzadeh ◽  
Sayed Mohamad Soleimani ◽  
Nemkumar Banthia

The purpose of this study was to investigate the influence of fiber reinforcement on the shear capacity of reinforced concrete (RC) beams. Both steel and synthetic fibers at variable volume fractions were investigated. Two series of tests were performed: structural tests, where RC beams were tested to failure under an applied four-point load; and materials tests, where companion fiber-reinforced concrete (FRC) prisms were tested under direct shear to obtain material properties such as shear strength and shear toughness. FRC test results indicated an almost linear increase in the shear strength of concrete with an increase in the fiber volume fraction. Fiber reinforcement enhanced the shear load capacity and shear deformation capacity of RC beams, but 1% fiber volume fraction was seen as optimal; no benefits were noted when the fiber volume fraction was increased beyond 1%. Finally, an equation is proposed to predict the shear capacity of RC beams.Key words: shear strength, fiber-reinforced concrete, RC beam, stirrups, energy absorption capacity, steel fiber, synthetic fiber.


2020 ◽  
Vol 23 (16) ◽  
pp. 3429-3445
Author(s):  
Fadi Oudah ◽  
Raafat El-Hacha

Shear deformation in reinforced concrete structures is of a complex nature. A thorough understanding of the interaction between the shear strength, flexural strength, and flexural ductility is not yet achieved. A new shear-deformation-based theory is proposed and validated in this study. The so-called two-discrete-elements (TDE) shear deformation theory idealizes reinforced concrete members as series of two discrete types of elements: S-elements and C-elements. The S-elements are used to model the regions of concrete reinforced to resist flexural and shear deformation using longitudinal and transverse steel reinforcement, while the C-elements are used to model the reinforced concrete sections bounded by the stirrups. The compatibility between the two types of elements is enforced by controlling the crack angle. The formulation of the newly developed theory is discussed in terms of equilibrium of forces, compatibility within the elements, compatibility at the interface, and constitutive material modeling. The theory was applied to evaluate the deformability of reinforced concrete shear walls subjected to lateral loads for seismic design applications. It was also implemented to generate sample design charts referred to as axial–moment–shear interaction diagrams. These diagrams can be used to design shear walls subjected to combined action of axial load, moment, and shear as opposed to the conventional interaction diagrams in which only the axial load versus moment relationship is considered. Analysis results indicated the adequacy of the proposed theory in capturing the shear strength degradation and predicting structural failures controlled by the shear capacity.


2011 ◽  
Vol 243-249 ◽  
pp. 514-520
Author(s):  
Chun Yang ◽  
Ming Ji He ◽  
Jian Cai ◽  
Yan Sheng Huang ◽  
Yi Wu

Based on strut-and-tie model (STM) in deep beams, steel truss reinforced concrete (STRC) deep beam was developed. Experimental investigations of mechanical performances of STRC deep beams were carried out, and results show that STRC deep beam is of high ultimate bearing capacity, large rigidity and good ductility; Strut-and-tie force transference model is formed in STRC deep beams, and loads can be transferred in the shortest and direct way. Then Steel reinforced concrete (SRC) strut-and-tie model (SSTM) for determining the shear strength of STRC deep beams is proposed. The contribution of SRC diagonal strut, longitudinal reinforcements, stirrups and web reinforcements to the shear strength of STRC deep beams are determined with consideration of softened effects of concrete, and for safe consideration, superposition theory is employed for SRC struts. Computer programs are developed to calculate the shear strength of STRC deep beams and verified by experimental results.


2019 ◽  
Vol 9 (2) ◽  
pp. 312 ◽  
Author(s):  
Wen-I Liao ◽  
Fu-Pei Hsiao ◽  
Chien-Kuo Chiu ◽  
Chin-En Ho

In this work, the piezoceramic-based transducers are used to perform the structural health monitoring (SHM) and interface damage detecting of non-ductile reinforced concrete (RC) frames retrofitted by post-installed RC walls. In order to develop the post-embedded piezoceramic-based transducers that can be used to identify interface failure or cracks between two structural members in retrofit construction, this work adopts the cyclic loading to test two specimens with post-embedded piezoceramic-based transducers (PPT). Since the failure of an interface between the post-installed wall and beam occurs, one of the specimens has damage in the foundation and existing boundary column and the other has damage in the top ends of column and wall. During the cyclic loading test, one transducer was used as an actuator to generate the stress waves and the other transducers were used as the sensors to detect the waves. In damaged specimens, the existence and locations of cracks and the interface damage can be detected by analyzing the wave response. Moreover, the severity of damage to the specimens can also be estimated. The experimental results indicate the effectiveness of the piezoceramic-based approach in the SHM and locating damage in shear-critical RC structural members under the seismic loading.


2006 ◽  
Vol 33 (8) ◽  
pp. 933-944 ◽  
Author(s):  
H El Chabib ◽  
M Nehdi ◽  
A Saïd

The exact effect that each of the basic shear design parameters exerts on the shear capacity of reinforced concrete (RC) beams without shear reinforcement (Vc) is still unclear. Previous research on this subject often yielded contradictory results, especially for reinforced high-strength concrete (HSC) beams. Furthermore, by simply adding Vc and the contribution of stirrups Vs to calculate the ultimate shear capacity Vu, current shear design practice assumes that the addition of stirrups does not alter the effect of shear design parameters on Vc. This paper investigates the validity of such a practice. Data on 656 reinforced concrete beams were used to train an artificial neural network model to predict the shear capacity of reinforced concrete beams and evaluate the performance of several existing shear strength calculation procedures. A parametric study revealed that the effect of shear reinforcement on the shear strength of RC beams decreases at a higher reinforcement ratio. It was also observed that the concrete contribution to shear resistance, Vc, in RC beams with shear reinforcement is noticeably larger than that in beams without shear reinforcement, and therefore most current shear design procedures provide conservative predictions for the shear strength of RC beams with shear reinforcement.Key words: analysis, artificial intelligence, beam depth, compressive strength, modeling, shear span, shear strength.


2020 ◽  
Vol 6 (10) ◽  
pp. 1852-1863
Author(s):  
Jun-Hyeok Song ◽  
Eun-Taik Lee ◽  
Hee-Chang Eun

Aged structures and structures constructed based on outdated non-seismic design codes should be retrofitted to enhance their strength, ductility, and durability. This study evaluates the structural performance of reinforced concrete (RC) columns enhanced via polyurea or glass fiber reinforced polyurea (GFRPU) strengthening. Four RC column specimens, including a reference specimen (an unstrengthened column), were tested to evaluate the parameters of the strengthening materials and the strengthened area. The tests were carried out under a combined constant axial compressive load and quasi-static cyclic loading. The experimental results show that the composite strengthening provides lateral confinement to the columns and leads to enhanced ductility, shear-resistance capacity, and dissipated energy. The shear strength provided by the composites depends on the degree of lateral confinement achieved by the composite coating. The specimens finally failed through the development of diagonal tension cracks within the potential plastic hinge regions. The specimen treated with GFRPU strengthening showed greater strength and dissipated more energy than the specimen treated with polyurea strengthening. Furthermore, by modifying ATC-40, this study proposed an equation to estimate the shear capacity provided by the composites.


2019 ◽  
Vol 5 (3) ◽  
pp. 528 ◽  
Author(s):  
Maroua Mohammed Majeed ◽  
Aamer Najim Abbas

This paper presents an experimental investigation on the punching shear strength of reinforced concrete flat plate slabs with shearhead collars. Eight reinforced concrete slab specimens were casted and tested under static load test, the load was applied at the center of slab by 100x100 mm steel column. The effect of the shapes, diameter and number of stiffeners has been discovered for shearheads through studying its effect on the load-deflection behavior, ultimate capacity, cracking load, failure mode, stiffness, ductility and energy absorption of tested specimens. The experimental results indicates that using square shearhead had achieved a slight increase in punching shear strength about 3% over that circular shearhead using the same surface area. Also, utilize 550 mm shearhead diameter will contribute to increase the punching shear strength about 14.5%. The increase in the number of stiffeners in specimen (CS4) had reduced the ultimate punching shear capacity by 20.3% over reference specimen. The first crack was decreased from 12.5kN to 7.5kN, when increases the number of stiffeners from one to two. The cracking load was increased with the increase of the diameter of circular shearhead from 10kN to 15Kn in specimens of 336mm and 550mm respectively. The specimen with 336mm diameter and 30mm height circular shearhead achieved 427 kN.m energy absorption, it is higher than the energy absorption of reference specimen by 2.6%. Also, using two stiffeners improved the energy absorption by 110.2% higher than the specimen with one stiffener.


Materials ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1711
Author(s):  
Changyong Li ◽  
Na Liang ◽  
Minglei Zhao ◽  
Kunqi Yao ◽  
Jie Li ◽  
...  

This paper is the outcome of experiments on the shear performance of reinforced concrete beams with approved composite-recycled aggregates. The strength grade of composite-recycled aggregate concrete (CRAC) was between 30 MPa and 60 MPa. The shear span-to-depth ratio varied from 1 to 3. The adaptability of HRB400 rebar, with critical yield strength of 400 MPa, used as stirrups was also verified. As the composite technology overcame the shortcomings of recycled coarse aggregate, CRAC had similar mechanical properties with those of conventional concrete. Details on the shear behaviors of test beams under a four-point loading test are presented. The results indicated that the changes of CRAC strain, stirrup strain, and shear-crack width depended on the failure patterns, which are controlled by the shear-span to depth ratio. The stirrups yield at the failure of reinforced CRAC beams. The shear cracking resistance and the shear capacity of reinforced CRAC beams can be predicted by the statistical equations. Based on the design codes GB50010, ACI318-19, Model Code 2010 and DIN-1045-1-2008 for conventional reinforced concrete beams, the shear strengths provided by CRAC and stirrups are statistical analyzed. The rationality of the design equations is examined by the utilization level of shear strength provided by CRAC. The maximum shear-crack widths are extracted from the test data of reinforced CRAC beams at normal service state. Comparatively, by specifying the lower limit of shear strength provided by the CRAC with various shear-span to depth ratios, China code GB50010 gives a rational method for utilizing CRAC. Under the premise that the design of shear capacity would give considerations to meet the normal serviceability, the factored strength of HRB400 rebar should be 360 MPa for the calculation of shear strength provided by stirrups. The design methods in codes of GB50010, ACI318-19 and Model Code 2010 are conservative for the shear capacity of reinforced CRAC beams.


2019 ◽  
Vol 9 (7) ◽  
pp. 1382 ◽  
Author(s):  
Jan Bielak ◽  
Viviane Adam ◽  
Josef Hegger ◽  
Martin Classen

A reliable and economic utilization of textile-reinforced concrete in construction requires appropriate design concepts. Unlike designs for bending, the development of models for shear is still the subject of current research. Especially for thin slabs, systematic experimental investigations are lacking. In this paper, the results of an experimental campaign on 27 carbon-textile reinforced slab segments tested in three-point bending are presented. The shear-span to depth ratio and member size were key variation parameters in this study. Increasing the structural depth of members led to a reduction in relative shear strength, while variation of shear slenderness controlled the efficiency of direct stress fields between load introduction and support. Interestingly, direct load transfer was activated up to a shear slenderness ratio of 4, which is significantly higher than in reinforced concrete (a/d < 2.5–3) and may result from the bond characteristics of the textile reinforcement. The experimental shear strengths were compared to predictions from existing models for shear of fiber-reinforced polymer (FRP)-reinforced concrete. The study shows that these FRP calculation models also predict the ultimate shear force for textile-reinforced concrete (TRC) tests presented in this paper with sufficient accuracy. Existing approaches for the size effect seem transferable as well. In order to validate the models for general use in TRC shear design, a compilation and comparison with larger experimental databases is required in future works.


Sign in / Sign up

Export Citation Format

Share Document