Few studies have provided in vivo tibiofemoral kinematics of the normal knee during dynamic weight-bearing activities. Indeed, gold standard measurement methods (i.e., intracortical pins and biplane imaging) raise ethical and experimental issues. Moreover, the conventions used for the processing of the kinematics show large inconsistencies. This study aims at synthesising the tibiofemoral kinematics measured with gold standard measurement methods. Published kinematic data were transformed in the standard recommended by the International Society of Biomechanics (ISB), and a clustering method was applied to investigate whether the couplings between the degrees of freedom (DoFs) are consistent among the different activities and measurement methods. The synthesised couplings between the DoFs during knee flexion (from 4° of extension to −61° of flexion) included abduction (up to −10°); internal rotation (up to 15°); and medial (up to 10 mm), anterior (up to 25 mm), and proximal (up to 28 mm) displacements. These synthesised couplings appeared mainly partitioned into two clusters that featured all the dynamic weight-bearing activities and all the measurement methods. Thus, the effect of the dynamic activities on the couplings between the tibiofemoral DoFs appeared to be limited. The synthesised data might be used as a reference of normal in vivo knee kinematics for prosthetic and orthotic design and for knee biomechanical model development and validation.


1981 ◽  
Vol 200 (2) ◽  
pp. 435-440 ◽  
Author(s):  
T Videman ◽  
I Eronen ◽  
T Candolin

Proline metabolism in vivo was studied during the development of immobilization osteoarthritis in rabbits. Collagen content was measured as the hydroxyproline concentration of the tissue in question. The incorporation of [3H]proline was used as the indicator for total protein synthesis; collagen synthesis rate was estimated from measurements of the specific radioactivity of hydroxyproline. Cartilage samples from knee and hip joints were analysed after 3, 7, 11, 18, 35 and 56 days of immobilization. The total protein and collagen synthesis rates of the immobilized legs increased and reached a maximum after 11-35 days. Although they decreased thereafter, these rates remained elevated to the end of the experiment. A slight increase in the synthetic activity of the non-immobilized contralateral legs was also detected after 7--18 days of immobilization. The isotope incorporation was markedly higher in tibial marginal tissue than in weight-bearing cartilage. In spite of the increased synthesis, no clear changes were found in the collagen content of the tissues studied during the experiment.


Author(s):  
Kartik M. Varadarajan ◽  
Angela Moynihan ◽  
Darryl D’Lima ◽  
Clifford W. Colwell ◽  
Harry E. Rubash ◽  
...  

Accurate knowledge of in vivo articular contact kinematics and contact forces is required to quantitatively understand factors limiting life of total knee arthroplasty (TKA) implants, such as polyethylene component wear and implant loosening [1]. Determination of in vivo tibiofemoral contact forces has been a challenging issue in biomechanics. Historically, instrumented tibial implants have been used to measure tibiofemoral forces in vitro [2] and computational models involving inverse dynamic optimization have been used to estimate joint forces in vivo [3]. Recently, D’Lima et al. reported the first in vivo measurement of 6DOF tibiofemoral forces via an instrumented implant in a TKA patient [4]. However this technique does not provide a direct estimation of tibiofemoral contact forces in the medial and lateral compartments. Recently, a dual fluoroscopic imaging system has been used to accurately determine tibiofemoral contact locations on the medial and lateral tibial polyethylene surfaces [5]. The objective of this study was to combine the dual fluoroscope technique and the instrumented TKAs to determine the dynamic 3D articular contact kinematics and contact forces on the medial and lateral tibial polyethylene surfaces during functional activities.


2021 ◽  
Vol 10 ◽  
pp. 100079
Author(s):  
Garrett D. Sheehan ◽  
Molly K. Martin ◽  
Violet A. Young ◽  
Rasheen Powell ◽  
Arin Bhattacharjee

2006 ◽  
Vol 31 (5) ◽  
pp. 524-529 ◽  
Author(s):  
B. W. SU ◽  
F. J. RAIA ◽  
H. M. QUITKIN ◽  
M. PARISIEN ◽  
R. J. STRAUCH ◽  
...  

The purpose of this study was to examine the in vivo characteristics of the stainless-steel Teno Fix™ device used for flexor tendon repair. The common flexor digitorum superficialis tendon was transected in 16 dogs and repaired with the device. The animals were euthanized at 3, 6, or 12 weeks postoperatively. Difficulties with cast immobilization led nine of 16 animals to be full weight bearing too early, leading to rupture of their repairs. The seven tendons with successful primary repairs (gap <2 mm) underwent histological examination. This in vivo study demonstrates that use of the Teno Fix™ in “suture” of dog flexor tendons did not lead to scarring at the tendon surface, does not cause an inflammatory reaction within the tendon and does not interfere with tendon healing.