Enjoyment of Music by Elderly Hearing-Impaired Listeners

2008 ◽  
Vol 19 (06) ◽  
pp. 519-526 ◽  
Author(s):  
Marjorie R. Leek ◽  
Michelle R. Molis ◽  
Lina R. Kubli ◽  
Jennifer B. Tufts

Background: Anecdotal evidence suggests that hearing loss interferes with the enjoyment of music, although it is not known how widespread this problem currently is. Purpose: To estimate the prevalence of music-listening difficulties among a group of elderly hearing aid wearers. Research Design: Interview. Telephone interviews were conducted with patients who wore hearing aids. Questions regarding several aspects of music listening were included. Study Sample: Sixty-eight hearing-impaired people served as subjects. They had all been seen in the audiology clinic for hearing aid evaluation during the previous year. Data Collection and Analysis: Subjects were asked questions concerning their use of hearing aids, the importance of listening to music in their lives, their habits and practices concerning music, and difficulties they experienced in listening to music. Results: Almost 30% of the respondents reported that their hearing losses affected their enjoyment of music. About half of the respondents indicated that music was either too loud or too soft, although only about one-third reported difficulties with level contrasts within musical pieces. In contrast to a similar survey carried out 20 years ago, there were many fewer complaints about listening to music. This result may be due in large part to improvements in hearing aids, especially with regard to nonlinear compression. Conclusions: Although new hearing aid technologies have somewhat reduced problems of music enjoyment experienced by hearing-impaired people, audiologists should be aware that some 25–30% of patients may have difficulties with listening to music and may require extra attention to minimize those problems.

2010 ◽  
Vol 21 (02) ◽  
pp. 078-089 ◽  
Author(s):  
Yu-Hsiang Wu

Background: Despite the recognition that the directional microphone hearing aid (DMHA) is an important intervention aimed at helping older hearing-impaired adults understand speech in noisy environments, there is little evidence that older listeners can actually benefit from directional processing. Purpose: The objective of this study was to determine if older and younger adults can obtain and perceive comparable benefit afforded by DMHAs. Study Sample: Twenty-four hearing-impaired adults aged 36 through 79 yr were fit with switchable-microphone hearing aids and tested in the laboratory and the field. Data Collection and Analysis: In the laboratory, the listeners’ directional benefit and preferences for microphone modes (directional vs. omnidirectional) were assessed using various speech-recognition-in-noise tests. In the four-week field trial, a paired-comparison technique and paper-and-pencil journals were used to determine the benefit provided by directional processing. The effects of age on directional benefit/preference were analyzed using generalized linear models with controlling for the effect of hearing loss. Results: The results revealed that age did not have a significant effect on directional benefit and preference as measured in the laboratory. However, the field data showed that older age was significantly associated with a lower preference for the directional mode. Conclusion: These results indicate that although listeners of different ages may obtain and perceive comparable benefit from DMHAs in laboratory testing, older users tend to perceive less benefit than do younger users in the real world. The implications of these findings are discussed.


2013 ◽  
Vol 24 (03) ◽  
pp. 174-191
Author(s):  
Sueli Aparecida Caporali ◽  
Erik Schmidt ◽  
Åsa Eriksson ◽  
Birgitta Sköld ◽  
Barbara Popecki ◽  
...  

Background: In spite of early identification and intervention efforts achieved by Early Hearing Detection and Intervention (EHDI) programs, many infants with hearing loss experience delays in early vocabulary development in comparison to peers with normal hearing (Mayne, Yoshinaga-Itano, Sedey, 2000a; Mayne, Yoshinaga-Itano, Sedey, Carey, 2000b; Moeller et al, 2007a, 2007b). One of the several factors that may contribute to individual differences in outcomes is inconsistent hearing aid use in this age group. This may be associated with the physical fit when using traditional behind-the-ear (BTE) hearing aids, since they are relatively large in comparison with the small and soft ear of an infant. Receiver-in-the-ear (RITE) hearing aids may be advantageous for use in pediatric fittings, since they are very tiny and lightweight and therefore sit comfortably on a small soft ear. Purpose: To evaluate the use of a RITE hearing aid with an instant ear-tip especially developed for infants in terms of physical fit, stability, safety, and security of the device, as well as the use of retention tools (remedies for keeping the hearing aid securely on the ear) with this age group. Research Design: A longitudinal study with hearing impaired infants fitted with RITE hearing aids was performed. Study Sample: Eighteen infants with mild to moderate/severe hearing loss participated in the study. The age range was 2–36 mo. Sixteen infants had worn hearing aids prior to their participation in the study. Intervention: Each hearing impaired infant was fitted with the RITE hearing aid and an instant ear-tip, the size of which was chosen by the audiologist. The infants used the device for a period of 2–5 mo. Data Collection and Analysis: Audiologists and parents completed questionnaires at every visit (5–7 visits in total). Responses were obtained using a category rating scale (Stevens, 1975) from 0 to 10. The data were analyzed using descriptive statistics and nonparametric statistics. Results: Sixteen of the 18 children completed the study. At the end of the study, 11 of the 16 children were using the instant ear-tip, whereas five children were fitted with the receiver mounted in a custom earmold. The audiologists rated the RITE solution to provide a safe, stable, and secure fit. The general trend was that ratings improved over time. At the final follow-up session, all median ratings were between 8 and 10. Conclusions: Based on the positive results obtained in the study, the use of an appropriately designed RITE hearing aid is recommended for infants.


This is about developing an android app for replicating the mechanism of hearing aid machine. Majority of the Hearing Impaired people cannot afford hearing aids due to higher cost of the Instruments. Similarly Audiometry Test for assessing the Deafness levels are also costly. Affordable Smartphone are available with majority of the Hearing Impaired people in Indian. So, we propose a Mobile Application which consists of the following three Features. This APP enables Ear phones of Phone to function as Hearing Aid for people with hearing disability. This APP converts speech to Text so that Hearing impaired people can know what other people are talking without using SIGN Language. This APP provides Pure-Tone AudiometryTest to assess level of Hearing Loss.


Author(s):  
Yu-Hsiang Wu ◽  
Elizabeth Stangl ◽  
Octav Chipara ◽  
Anna Gudjonsdottir ◽  
Jacob Oleson ◽  
...  

Abstract Background Ecological momentary assessment (EMA) is a methodology involving repeated surveys to collect in-situ self-reports that describe respondents' current or recent experiences. Audiology literature comparing in-situ and retrospective self-reports is scarce. Purpose To compare the sensitivity of in-situ and retrospective self-reports in detecting the outcome difference between hearing aid technologies, and to determine the association between in-situ and retrospective self-reports. Research Design An observational study. Study Sample Thirty-nine older adults with hearing loss. Data Collection and Analysis The study was part of a larger clinical trial that compared the outcomes of a prototype hearing aid (denoted as HA1) and a commercially available device (HA2). In each trial condition, participants wore hearing aids for 4 weeks. Outcomes were measured using EMA and retrospective questionnaires. To ensure that the outcome data could be directly compared, the Glasgow Hearing Aid Benefit Profile was administered as an in-situ self-report (denoted as EMA-GHABP) and as a retrospective questionnaire (retro-GHABP). Linear mixed models were used to determine if the EMA- and retro-GHABP could detect the outcome difference between HA1 and HA2. Correlation analyses were used to examine the association between EMA- and retro-GHABP. Results For the EMA-GHABP, HA2 had significantly higher (better) scores than HA1 in the GHABP subscales of benefit, residual disability, and satisfaction (p = 0.029–0.0015). In contrast, the difference in the retro-GHABP score between HA1 and HA2 was significant only in the satisfaction subscale (p = 0.0004). The correlations between the EMA- and retro-GHABP were significant in all subscales (p = 0.0004 to <0.0001). The strength of the association ranged from weak to moderate (r = 0.28–0.58). Finally, the exit interview indicated that 29 participants (74.4%) preferred HA2 over HA1. Conclusion The study suggests that in-situ self-reports collected using EMA could have a higher sensitivity than retrospective questionnaires. Therefore, EMA is worth considering in clinical trials that aim to compare the outcomes of different hearing aid technologies. The weak to moderate association between in-situ and retrospective self-reports suggests that these two types of measures assess different aspects of hearing aid outcomes.


Author(s):  
Tadashi Nishimura ◽  
Hiroshi Hosoi ◽  
Tomoko Sugiuchi ◽  
Nozomu Matsumoto ◽  
Takanori Nishiyama ◽  
...  

Abstract Background Cartilage conduction hearing aids (CCHAs) were newly devised and spread fast in Japan since their launch in 2017. However, little knowledge is available for this new device. Purpose The aim of this study was to establish the knowledge of CCHAs and suggest their indication. Research Design Correlational study. Study Sample A total 256 patients were registered. Data Collection and Analysis The fitting of CCHAs was surveyed in nine institutions. The outcomes were assessed by audiometric tests. The patients were classified into seven groups, depending on the ear conditions. The clinical characteristics, assessment results, and purchase rates were compared among the groups. The assessment results of CCHAs were also compared with those of previously used hearing aids. Results Most patients who used CCHAs were classified into the bilateral closed (aural atresia or severe stenosis) ear (n = 65) or unilateral closed ear (n = 124) groups. The patients in these groups achieved good benefits that resulted in a high purchase rate. The bilateral continuous otorrhea group also supported a high purchase rate, although the benefits of CCHAs were not always excellent. In contrast, the purchase rate was poor in the patients who could use air conduction hearing aids (ACHAs) without absolute problems. As for using a CCHA as a contralateral routing of signals hearing aid, the benefits depended on the patients. Conclusions CCHAs are considered as a great option not only to the patients with closed ears but also to those who had difficulties in ACHAs usage.


2020 ◽  
pp. 132-136
Author(s):  
Hiroshi Ikeda ◽  
Shigeyuki Minami

Hearing impaired persons are required to drive with hearing aids to supplement their hearing ability, however, there has not been sufficient discussion regarding the impact of the use of a hearing aid on driving a vehicle. In order to investigate the actual usage and driving conditions of using hearing aids while driving a vehicle, this paper uses a questionnaire to survey (1) how easy it is to drive when wearing hearing aids, and (2) how often hearing aids are not worn while driving. Concerning the ease of driving when wearing a hearing aid, it was suggested that people with congenital hearing loss were more likely to rely on visual information, and those with acquired hearing loss continue to use their experience of hearing. When the level of disability is high, it is difficult to drive when using the hearing aid, and when the disability level is low, it is easier to drive. Regarding the frequency of driving without wearing hearing aids, about 60 % of respondents had such an experience. Those who often drive without hearing aids had experienced headaches due to noise from wearing hearing aids compared to those who wear hearing aids at all times. Hearing aids are necessary assistive devices for hearing impaired persons to obtain hearing information, and to provide a safe driving environment. Therefore, this paper addresses issues to maintain a comfortable driving environment while wearing a hearing aid.


1990 ◽  
Vol 33 (4) ◽  
pp. 676-689 ◽  
Author(s):  
David A. Fabry ◽  
Dianne J. Van Tasell

The Articulation Index (AI) was used to evaluate an “adaptive frequency response” (AFR) hearing aid with amplification characteristics that automatically change to become more high-pass with increasing levels of background noise. Speech intelligibility ratings of connected discourse by normal-hearing subjects were predicted well by an empirically derived AI transfer function. That transfer function was used to predict aided speech intelligibility ratings by 12 hearing-impaired subjects wearing a master hearing aid with the Argosy Manhattan Circuit enabled (AFR-on) or disabled (AFR-off). For all subjects, the AI predicted no improvements in speech intelligibility for the AFR-on versus AFR-off condition, and no significant improvements in rated intelligibility were observed. The ability of the AI to predict aided speech intelligibility varied across subjects. However, ratings from every hearing-impaired subject were related monotonically to AI. Therefore, AI calculations may be used to predict relative—but not absolute—levels of speech intelligibility produced under different amplification conditions.


1998 ◽  
Vol 87 (2) ◽  
pp. 703-706 ◽  
Author(s):  
Gerhard Andersson

In this report data on hearing aid use were combined from three randomized controlled studies on behavioural hearing tactics. Daily average hearing aid use at pretreatment and posttreatment were analysed for 63 older hearing-impaired persons who had either received treatment or acted as controls. Analysis showed a significant, albeit weak, decrease in daily hearing aid use for those subjects who had received the treatment. The utility of amount of hearing aid use as an indicator of rehabilitation success is discussed.


2020 ◽  
Vol 31 (05) ◽  
pp. 354-362
Author(s):  
Paula Folkeard ◽  
Marlene Bagatto ◽  
Susan Scollie

Abstract Background Hearing aid prescriptive methods are a commonly recommended component of evidence-based preferred practice guidelines and are often implemented in the hearing aid programming software. Previous studies evaluating hearing aid manufacturers' software-derived fittings to prescriptions have shown significant deviations from targets. However, few such studies examined the accuracy of software-derived fittings for the Desired Sensation Level (DSL) v5.0 prescription. Purpose The purpose of this study was to evaluate the accuracy of software-derived fittings to the DSL v5.0 prescription, across a range of hearing aid brands, audiograms, and test levels. Research Design This study is a prospective chart review with simulated cases. Data Collection and Analysis A set of software-derived fittings were created for a six-month-old test case, across audiograms ranging from mild to profound. The aided output from each fitting was verified in the test box at 55-, 65-, 75-, and 90-dB SPL, and compared with DSL v5.0 child targets. The deviations from target across frequencies 250-6000 Hz were calculated, together with the root-mean-square error (RMSE) from target. The aided Speech Intelligibility Index (SII) values generated for the speech passages at 55- and 65-dB SPL were compared with published norms. Study Sample Thirteen behind-the-ear style hearing aids from eight manufacturers were tested. Results The amount of deviation per frequency was dependent on the test level and degree of hearing loss. Most software-derived fittings for mild-to-moderately severe hearing losses fell within ± 5 dB of the target for most frequencies. RMSE results revealed more than 84% of those hearing aid fittings for the mild-to-moderate hearing losses were within 5 dB at all test levels. Fittings for severe to profound hearing losses had the greatest deviation from target and RMSE. Aided SII values for the mild-to-moderate audiograms fell within the normative range for DSL pediatric fittings, although they fell within the lower portion of the distribution. For more severe losses, SII values for some hearing aids fell below the normative range. Conclusions In this study, use of the software-derived manufacturers' fittings based on the DSL v5.0 pediatric targets set most hearing aids within a clinically acceptable range around the prescribed target, particularly for mild-to-moderate hearing losses. However, it is likely that clinician adjustment based on verification of hearing aid output would be required to optimize the fit to target, maximize aided SII, and ensure appropriate audibility across all degrees of hearing loss.


2009 ◽  
Vol 20 (06) ◽  
pp. 374-380 ◽  
Author(s):  
Sherri L. Smith ◽  
Colleen M. Noe ◽  
Genevieve C. Alexander

Background: The International Outcome Inventory for Hearing Aids (IOI-HA) was developed as a global hearing aid outcome measure targeting seven outcome domains. The published norms were based on a private-pay sample who were fitted with analog hearing aids. Purpose: The purpose of this study was to evaluate the psychometric properties of the IOI-HA and to establish normative data in a veteran sample. Research Design: Survey. Study Sample: The participants were 131 male veterans (mean age of 74.3 years, SD = 7.4) who were issued hearing aids with digital signal processing (DSP). Intervention: Hearing aids with DSP that were fitted bilaterally between 2005 and 2007. Data Collection and Analysis: Veterans were mailed two copies of the IOI-HA. The participants were instructed to complete the first copy of the questionnaire immediately and the second copy in two weeks. The completed questionnaires were mailed to the laboratory. The psychometric properties of the questionnaire were evaluated. As suggested by Cox and colleagues, the participants were divided into two categories based on their unaided subjective hearing difficulty. The two categories were (1) those with less hearing difficulty (none-to-moderate category) and (2) those who report more hearing difficulty (moderately severe+ category). The norms from the current veteran sample then were compared to the original, published sample. For each hearing difficulty category, the critical difference values were calculated for each item and for the total score. Results: A factor analysis showed that the IOI-HA in the veteran sample had the identical subscale structure as reported in the original sample. For the total scale, the internal consistency was good (Chronbach's α = 0.83), and the test–retest reliability was high (λ = 0.94). Group and individual norms were developed for both hearing difficulty categories in the veteran sample. For each IOI-HA item, the critical difference scores were <1.0. This finding suggests that for any item on the IOI-HA, there is a 95 percent chance that an observed change of one response unit between two test sessions reflects a true change in outcome for a given domain. Conclusions: The results of this study confirmed that the psychometric properties of the IOI-HA questionnaire are strong and are essentially the same for the veteran sample and the original private-pay sample. The veteran norms, however, produced higher outcomes than those established originally, possibly because of differences in the population samples and/or hearing aid technology. Clinical and research applications of the current findings are presented. Based on the results from the current study, the norms established here should replace the original norms for use in veterans with current hearing aid technology.


Sign in / Sign up

Export Citation Format

Share Document