scholarly journals Development and Validation of a Reversed-phase High Performance Liquid Chromatography Method for the Simultaneous Estimation of Rosuvastatin Calcium and Telmisartan in Fixed-Dose Complex Dual-Layer Tablets in Six Dosage Forms

2021 ◽  
Vol 83 (3) ◽  
Author(s):  
Min Nyeong Choi ◽  
Y. J. Park ◽  
Joo Eun Kim
2020 ◽  
Vol 10 (4) ◽  
pp. 79-86
Author(s):  
Awdhut Pimpale ◽  
Rajendra Kakde

A Simple, precise, and accurate stability-indicating reversed-phase high-performance liquid chromatography method has been established for the simultaneous estimation of rosuvastatin calcium and fenofibrate in combined bulk and tablet formulation. The chromatographic separation was performed on reverse phase Princeton (C18) (250 mm x 4.6 mm, 5µ) column with mobile phase as a mixture of water (pH adjusted to 3.0 with orthophosphoric acid) and acetonitrile in the ratio (40:60) v/v at the flow rate 1.0 ml/min. Detection was carried out at wavelength 240 nm. The retention time under the optimized condition of Rosuvastatin calcium and Fenofibrate was found to be 2.485 & 3.905 minutes respectively. The calibration curve was linear in the range of 6-16 µg/ml and 87-232 µg/ml for rosuvastatin calcium and fenofibrate with a correlation coefficient of 0.9999 and 0.9994 respectively. Relative standard deviation values for all key parameters were less than 2.0%. The percentage recovery was found to be 99.66-100.37% and 99.13-100.44% for rosuvastatin calcium and fenofibrate respectively. The developed reversed-phase high-performance liquid chromatography method was found to be simple, specific, sensitive, rapid, linear, accurate, precise, and economical, and could be used for regular quality control of rosuvastatin calcium and fenofibrate in bulk and tablet formulations.  Keywords: Rosuvastatin calcium, Fenofibrate, RP-HPLC, Method validation, ICH guidelines.


INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (01) ◽  
pp. 35-40
Author(s):  
A. S. Bagde ◽  
V. V. Khanvilkar ◽  

The present work describes a validated reverse phase high performance liquid chromatography (RPHPLC) method for simultaneous estimation of dextromethorphan hydrobromide and quinidine sulphate in pharmaceutical dosage from. The drugs were resolved using Hemochrom Intsil C18-5U column (250×4.6) mm in isocratic mode with mobile phase methanol: water (0.08% diethylamine, 0.02% of glacial acetic acid and pH 4.4 adjusted with orthophosphoric acid) in the ratio of 70:30 V/V at a flow rate of 1.0 mL/min. Retention time of dextromethorphan hydrobromide and quinidine sulphate were 4.9±0.2 and 3.6±0.2, respectively, at 292nm. The above mentioned method was validated as per International Conference on Harmonization (ICH) guidelines. Linear responses were obtained in concentration ranges of 5-35 μg/mL for dextromethorphan hydrobromide and 4-16 μg/mL for quinidine sulphate, with correlation coefficient (r2) of 0.999 for both the drugs. A simple, selective, accurate, precise, robust and reliable RP-HPLC method thus developed and validated for simultaneous estimation of dextromethorphan hydrobromide and quinidine sulphate.


Author(s):  
Mannem Durga Babu ◽  
Kesana Surendrababu

Objective: The objective of the study was to develop and validate a novel, specific, precise, and simple reversed-phase high-performance liquid chromatography method for the estimation of guaifenesin present in methocarbamol API and its pharmaceutical dosage forms. Methods: The baseline separation for methocarbamol and guaifenesin was achieved by utilizing a Inertsil ODS C18 (250 mm × 4.6 mm) 5 μm column particle size and an isocratic elution method. The mobile phase contains a mixture of water and acetonitrile in the ratio of 70:30 v/v, respectively. The flow rate of the mobile phase was 1.0 mL/min with a column temperature of 25°C and detection wavelength at 272 nm. The method was validated for a limit of detection (LOD), limit of quantification (LOQ), linearity, accuracy, and reproducibility with the help of the exhibit and simulated samples. Results: The LOD for guaifenesin was 0.62 μg/mL. The LOQ for guaifenesin was 1.87 μg/mL. The correlation coefficient obtained for impurity was >0.99. The recovery was obtained for impurity was 106.56% at 50%, 95.20% at 100%, and 100.45% at 150%. In tablet analysis, we can found 0.26% (<0.5%). Conclusion: The developed method was validated as per the ICH guidelines with respect to specificity, precision, linearity, accuracy, LOD and quantification, ruggedness, robustness, and solution stability.


Author(s):  
Sufiyan Ahmad ◽  
Mohammed Rageeb Mohammed Usman

  Objective: A simple rapid, accurate, precise, and reproducible validated reversed-phase high performance liquid chromatography method was developed for the determination of emtricitabine (EMB) and tenofovir (TEN) in bulk and tablet dosage forms.Methods: The quantification was carried out using symmetry Premsil C18 (250 mm×4.6 mm, 5 μm) Younglin (S.K.) gradient way using mobile phase comprising of methanol:water (70:30 v/v) pH 3 and a detection wavelength of 273 nm, and injection volume of 20 μL, with a flow rate of 1 ml/minutes.Results: In the developed method, the retention time of EMB and TEN were found to be 3.1667 minutes and 7.5000 minutes. The developed method was validated according to the International Conference on Harmonization (ICH) guidelines.Conclusion: The linearity, precision, range, robustness was within the limits as specified by the ICH guidelines. Hence, the method was found to be simple, accurate, precise, economic, and reproducible. Hence, it is worthwhile that the proposed methods can be successfully utilized for the routine quality control analysis EMB and TEN in bulk drug as well as in formulations.