scholarly journals Agile mobile robotic platform for contactless vital signs monitoring

Author(s):  
Hen-Wei Huang ◽  
peter chai ◽  
Claas Ehmke ◽  
Gene Merewether ◽  
Fara Dadabhoy ◽  
...  

The COVID-19 pandemic has accelerated methods to facilitate contactless evaluation of patients in hospital settings. By minimizing unnecessary in-person contact with individuals who may have COVID-19 disease, healthcare workers (HCW) can prevent disease transmission, and conserve personal protective equipment. Obtaining vital signs is a ubiquitous task that is commonly done in-person. To eliminate the need for in-person contact for vital signs measurement in the hospital setting, we developed Dr. Spot, an agile quadruped robotic system that comprises a set of contactless monitoring systems for measuring vital signs and a tablet computer to enable face-to-face medical interviewing. Dr. Spot is teleoperated by trained clinical staff to facilitate enhanced telemedicine. Specifically, it has the potential to simultaneously measure skin temperature, respiratory rate, heart rate, and blood oxygen saturation simultaneously while maintaining social distancing from the patients. This is important because fluctuations in vital sign parameters are commonly used in algorithmic decisions to admit or discharge individuals with COVID-19 disease. Here, we deployed Dr. Spot in a hospital setting with the ability to measure the vital signs from healthy volunteers from which the measurements of elevated skin temperature screening, respiratory rate, heart rate, and SpO2 were carefully verified with ground-truth sensors.

2020 ◽  
Author(s):  
Hen-Wei Huang ◽  
peter chai ◽  
Claas Ehmke ◽  
Gene Merewether ◽  
Fara Dadabhoy ◽  
...  

The COVID-19 pandemic has accelerated methods to facilitate contactless evaluation of patients in hospital settings. By minimizing unnecessary in-person contact with individuals who may have COVID-19 disease, healthcare workers (HCW) can prevent disease transmission, and conserve personal protective equipment. Obtaining vital signs is a ubiquitous task that is commonly done in-person. To eliminate the need for in-person contact for vital signs measurement in the hospital setting, we developed Dr. Spot, an agile quadruped robotic system that comprises a set of contactless monitoring systems for measuring vital signs and a tablet computer to enable face-to-face medical interviewing. Dr. Spot is teleoperated by trained clinical staff to facilitate enhanced telemedicine. Specifically, it has the potential to simultaneously measure skin temperature, respiratory rate, heart rate, and blood oxygen saturation simultaneously while maintaining social distancing from the patients. This is important because fluctuations in vital sign parameters are commonly used in algorithmic decisions to admit or discharge individuals with COVID-19 disease. Here, we deployed Dr. Spot in a hospital setting with the ability to measure the vital signs from healthy volunteers from which the measurements of elevated skin temperature screening, respiratory rate, heart rate, and SpO2 were carefully verified with ground-truth sensors.


Author(s):  
Muhammad Niswar ◽  
Muhammad Nur ◽  
Idar Mappangara

Medical devices are often expensive, so people in low-income countries cannot afford them. This paper presents the design of a low-cost wearable medical device to measure vital signs of a patient including heart rate, blood oxygen saturation level (SpO2) and respiratory rate. The wearable medical device mainly consists of a microcontroller and two biomedical sensors including airflow thermal sensor to measure respiratory rate and pulse oximeter sensor to measure SpO2 and heart rate. We can monitor the vital signs from a smartphone using a web browser through IEEE802.11 wireless connectivity to the wearable medical device. Furthermore, the wearable medical device requires simple management to operate; hence, it can be easily used. Performance evaluation results show that the designed wearable medical device works as good as a standard SpO2 device and it can measure the respiratory rate properly.  The designed wearable medical device is inexpensive and appropriate for low-resource settings. Moreover, as its components are commonly available in the market, it easy to assembly and repair locally.


Sensors ◽  
2019 ◽  
Vol 19 (8) ◽  
pp. 1874 ◽  
Author(s):  
Sally K. Longmore ◽  
Gough Y. Lui ◽  
Ganesh Naik ◽  
Paul P. Breen ◽  
Bin Jalaludin ◽  
...  

Monitoring of vital signs is critical for patient triage and management. Principal assessments of patient conditions include respiratory rate heart/pulse rate and blood oxygen saturation. However, these assessments are usually carried out with multiple sensors placed in different body locations. The aim of this paper is to identify a single location on the human anatomy whereby a single 1 cm × 1 cm non-invasive sensor could simultaneously measure heart rate (HR), blood oxygen saturation (SpO2), and respiration rate (RR), at rest and while walking. To evaluate the best anatomical location, we analytically compared eight anatomical locations for photoplethysmography (PPG) sensors simultaneously acquired by a single microprocessor at rest and while walking, with a comparison to a commercial pulse oximeter and respiration rate ground truth. Our results show that the forehead produced the most accurate results for HR and SpO2 both at rest and walking, however, it had poor RR results. The finger recorded similar results for HR and SpO2, however, it had more accurate RR results. Overall, we found the finger to be the best location for measurement of all three parameters at rest; however, no site was identified as capable of measuring all parameters while walking.


2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 914.2-914
Author(s):  
S. Boussaid ◽  
M. Ben Majdouba ◽  
S. Jriri ◽  
M. Abbes ◽  
S. Jammali ◽  
...  

Background:Music therapy is based on ancient cross-cultural beliefs that music can have a “healing” effect on mind and body. Research determined that listening to music can increase comfort and relaxation, relieve pain, lower distress, reduce anxiety, improve positive emotions and mood, and decrease psychological symptoms. Music therapy has been used greatly in various medical procedures to reduce associated anxiety and pain. Patients have a high level of anxiety when they are in the hospital, this is the case of patients with rheumatic diseases who consult regularly to have intravenous infusion of biological therapies.Objectives:The purpose of this study was to examine the effectiveness of music therapy on pain, anxiety, and vital signs among patients with chronic inflammatory rheumatic diseases during intravenous infusion of biological drugs.Methods:Fifty patients were divided into two groups: The experimental group G1 (n=25) received drug infusion while lestening to soft music (30 minutes); and the control group G2 (n=25) received only drug infusion. Measures include pain, anxiety, vital signs (blood pressure, heart rate and respiratory rate). The pain was measured using visual analogic scale (VAS). The state-trait anxiety inventory (STAI) was used for measuring anxiety, low anxiety ranges from 20 to 39, the moderate anxiety ranges from 40 to 59, and high anxiety ranges from 60 to 80. Vital signs (systolic blood pressure [SBP], diastolic blood pressure [DBP], heart rate [HR], and respiratory rate [RR]) were measured before, during and immediately after the infusion.Statistical package for social sciences (SPSS) was used for analysis.Results:The mean age in G1 was 44.45 years (26-72) with a sex ratio (M/F) of 0.8. Including the 25 patients, 12 had rheumatoid arthritis, 10 had ankylosing spondylitis and 3 had psoriatic arthritis. The mean disease duration was 8 years. In G2, the mean age was 46 years (25-70) with a sex ratio (M/F) of 0.75, 12 had rheumatoid arthritis, 11 had ankylosing spondylitis and 2 had psoriatic arthritis. The mean disease duration was 7.5 years. The biological drugs used were: Infliximab in 30 cases, Tocilizumab in 12 cases and Rituximab in 8 cases.Before the infusion, the patients of experimental group had a mean VAS of 5/10±3, a mean STAI of 50.62±6.01, a mean SBP of 13.6 cmHg±1.4, a mean DBP of 8.6 cmHg±1, a mean HR of 85±10 and a mean RR of 18±3. While in control group the mean VAS was 5.5±2, the mean STAI was 50.89±5.5, the mean SBP was 13.4±1.2, the mean DBP was 8.8±1.1, the mean HR was 82±8 and the mean RR was 19±2.During the infusion and after music intervention in G1, the mean STAI became 38.35±5 in G1 versus 46.7±5.2 in G2 (p value=0.022), the mean SBP became 12.1±0.5 in G1 versus 13±1 in G2 (p=0.035), the mean DBP became 8.1±0.8 in G1 versus 8.4±0.9 in G2 (p=0.4), the mean HR became 76±9 in G1 versus 78±7 in G2 (p=0.04) and the mean RR became 17.3±2.1 in G1 versus 18.2±1.7 in G2 (p=0.39).This study found a statistically significant decrease in anxiety, systolic blood pressure and heart rate in patients receiving music interventions during biological therapies infusion, but no significant difference were identified in diastolic blood pressure and respiratory rate.Conclusion:The findings provide further evidence to support the use of music therapy to reduce anxiety, and lower systolic blood pressure and heart rate in patients with rheumatic disease during biological therapies infusion.References:[1] Lin, C., Hwang, S., Jiang, P., & Hsiung, N. (2019).Effect of Music Therapy on Pain After Orthopedic Surgery -A Systematic review and Meta-Analysis. Pain Practice.Disclosure of Interests:None declared


2018 ◽  
Vol 2018 ◽  
pp. 1-13 ◽  
Author(s):  
Carlo Massaroni ◽  
Daniel Simões Lopes ◽  
Daniela Lo Presti ◽  
Emiliano Schena ◽  
Sergio Silvestri

Vital signs monitoring is pivotal not only in clinical settings but also in home environments. Remote monitoring devices, systems, and services are emerging as tracking vital signs must be performed on a daily basis. Different types of sensors can be used to monitor breathing patterns and respiratory rate. However, the latter remains the least measured vital sign in several scenarios due to the intrusiveness of most adopted sensors. In this paper, we propose an inexpensive, off-the-shelf, and contactless measuring system for respiration signals taking as region of interest the pit of the neck. The system analyses video recorded by a single RGB camera and extracts the respiratory pattern from intensity variations of reflected light at the level of the collar bones and above the sternum. Breath-by-breath respiratory rate is then estimated from the processed breathing pattern. In addition, the effect of image resolution on monitoring breathing patterns and respiratory rate has been investigated. The proposed system was tested on twelve healthy volunteers (males and females) during quiet breathing at different sensor resolution (i.e., HD 720, PAL, WVGA, VGA, SVGA, and NTSC). Signals collected with the proposed system have been compared against a reference signal in both the frequency domain and time domain. By using the HD 720 resolution, frequency domain analysis showed perfect agreement between average breathing frequency values gathered by the proposed measuring system and reference instrument. An average mean absolute error (MAE) of 0.55 breaths/min was assessed in breath-by-breath monitoring in the time domain, while Bland-Altman showed a bias of −0.03 ± 1.78 breaths/min. Even in the case of lower camera resolution setting (i.e., NTSC), the system demonstrated good performances (MAE of 1.53 breaths/min, bias of −0.06 ± 2.08 breaths/min) for contactless monitoring of both breathing pattern and breath-by-breath respiratory rate over time.


Author(s):  
Seung-Ho Park ◽  
Kyoung-Su Park

Abstract As the importance of continuous vital signs monitoring increases, the need for wearable devices to measure vital sign is increasing. In this study, the device is designed to measure blood pressure (BP), respiratory rate (RR), and heartrate (HR) with one sensor. The device is in earphone format and is manufactured as wireless type using Arduino-based bluetooth module. The device measures pulse signal in the Superficial temporal artery using Photoplethysmograghy (PPG) sensor. The device uses the Auto Encoder to remove noise caused by movement, etc., contained in the pulse signal. Extract the feature from the pulse signal and use them for the vital sign measurement. The device is measured using Slope transit time (STT) method for BP and Respiratory sinus arrhythmia (RSA) method for RR. Finally, the accuracy is determined by comparing the vital signs measured through the device with the reference vital signs measured simultaneously.


Children ◽  
2020 ◽  
Vol 7 (8) ◽  
pp. 89
Author(s):  
Woori Bae ◽  
Kyunghoon Kim ◽  
Bongjin Lee

To effectively use vital signs as indicators in children, the magnitude of deviation from expected vital sign distribution should be determined. The purpose of this study is to derive age-specific centile charts for the heart rate and respiratory rate of the children who visited the emergency department. This study used the Korea’s National Emergency Department Information System dataset. Patients aged <16 years visiting the emergency department between 1 January 2016 and 31 December 2017 were included. Heart rate and respiratory rate centile charts were derived from the population with normal body temperature (36 to <38 °C). Of 1,901,816 data points retrieved from the database, 1,454,372 sets of heart rates and 1,458,791 sets of respiratory rates were used to derive centile charts. Age-specific centile charts and curves of heart rates and respiratory rates showed a decline in heart rate and respiratory rate from birth to early adolescence. There were substantial discrepancies in the reference ranges of Advanced Paediatric Life Support and Pediatric Advanced Life Support guidelines. Age-based heart rate and respiratory rate centile charts at normal body temperature, derived from children visiting emergency departments, serve as new evidence-based data and can be used in follow-up studies to improve clinical care for children.


2019 ◽  
Vol 2 (1) ◽  
Author(s):  
Mauricio Villarroel ◽  
Sitthichok Chaichulee ◽  
João Jorge ◽  
Sara Davis ◽  
Gabrielle Green ◽  
...  

AbstractThe implementation of video-based non-contact technologies to monitor the vital signs of preterm infants in the hospital presents several challenges, such as the detection of the presence or the absence of a patient in the video frame, robustness to changes in lighting conditions, automated identification of suitable time periods and regions of interest from which vital signs can be estimated. We carried out a clinical study to evaluate the accuracy and the proportion of time that heart rate and respiratory rate can be estimated from preterm infants using only a video camera in a clinical environment, without interfering with regular patient care. A total of 426.6 h of video and reference vital signs were recorded for 90 sessions from 30 preterm infants in the Neonatal Intensive Care Unit (NICU) of the John Radcliffe Hospital in Oxford. Each preterm infant was recorded under regular ambient light during daytime for up to four consecutive days. We developed multi-task deep learning algorithms to automatically segment skin areas and to estimate vital signs only when the infant was present in the field of view of the video camera and no clinical interventions were undertaken. We propose signal quality assessment algorithms for both heart rate and respiratory rate to discriminate between clinically acceptable and noisy signals. The mean absolute error between the reference and camera-derived heart rates was 2.3 beats/min for over 76% of the time for which the reference and camera data were valid. The mean absolute error between the reference and camera-derived respiratory rate was 3.5 breaths/min for over 82% of the time. Accurate estimates of heart rate and respiratory rate could be derived for at least 90% of the time, if gaps of up to 30 seconds with no estimates were allowed.


2019 ◽  
Vol 28 (19) ◽  
pp. 1256-1259
Author(s):  
Malcolm Elliott ◽  
Jill Baird

Clinical surveillance provides essential data on changes in a patient's condition. The common method for performing this surveillance is the assessment of vital signs. Despite the importance of these signs, research has found that vital signs are not rigorously assessed in clinical practice. Respiratory rate, arguably the most important vital sign, is the most neglected. Poor understanding might contribute to nurses incorrectly valuing oxygen saturation more than respiratory rate. Nurses need to understand the importance of respiratory rate assessment as a vital sign and the benefits and limitations of pulse oximetry as a clinical tool. By better understanding pulse oximetry and respiratory rate assessment, nurses might be more inclined to conduct rigorous vital signs' assessment. Research is needed to understand why many nurses do not appreciate the importance of vital signs' monitoring.


1959 ◽  
Vol 52 (3) ◽  
pp. 305-312 ◽  
Author(s):  
W. Bianca

1. Three calves were exposed in a climatic room to an environment of 40° C. dry-bulb and 38° C. wet-bulb temperature for up to 110 min. each day for 1-2 weeks.2. These exposures produced progressive changes in the physiological reactions of the animals to heat:(a) Rectal temperature and skin temperature (for a given time of exposure) declined. In consequence there was a marked increase in the tolerance time, i.e. in the time for which the animals could withstand the hot environment before reaching a rectal temperature of 42° C.(b) Respiratory rate rose earlier and assumed higher levels (for given levels of body temperature).(c) Heart rate decreased markedly.3. These changes are discussed in relation to heat loss and heat production and have been interpreted as reflecting chiefly a reduction in the metabolic heat production of the animals.