scholarly journals Does Percutaneous Vertebroplasty or Balloon Kyphoplasty for Osteoporotic Vertebral Compression Fractures Increase the Incidence of New Vertebral Fractures? A Meta-Analysis

2017 ◽  
Vol 1 (21;1) ◽  
pp. E13-E28 ◽  
Author(s):  
Tao Zhang

Background: Because of an aging population,osteoporotic vertebral fractures are becoming more frequent. Conservative therapy was considered the gold standard for treating osteoporotic vertebral compression fractures (OVCFs) in the past. Percutaneous vertebroplasty (PVP) or balloon kyphoplasty (BKP) as minimally invasive techniques are new treatments that arewidely used for painful OVCFs. However, an increase in new vertebral compression fractures at non-treated levels following augmentation is of concern. There is no convincing evidence that new fractures are inevitable after augmentation compared to after conservative treatment, and it is still unclear whether further fractures are the consequence of augmentation ora result of the natural progression of osteoporosis. Objective: The objective of this study was to evaluate the new-level fracture risk after PVP or BKP compared with conservative (non-operative) treatment and to determine the dominant risk factor associated with new OVCFs. Study Design: A meta-analysis of comparative studies was performed to evaluate the incidence of new vertebral fractures between vertebral augmentation, such as vertebroplasty and kyphoplasty, and no operation. Setting: The PubMed,ISI Web of Science, ELSEVIER ScienceDirect, and Cochrane Library databases and abstracts published in annual proceedings were systematically searched.In addition, we also retrieved data from references when titles met our inclusion criteria. Methods: Detailed searches of a number of online databases comparing operative and non-operative groups were performed. We included randomized controlled trials,clinical controlled trials,and prospective clinical studies to provide available data. All studies were reviewed by 2 reviewers independently, and all the references that met our inclusion criteria were searched for additional trials, using the guidelines set by the QUOROM (Quality of Reporting of Meta-analysis) statement. Results: We evaluated 12 studies encompassing 1,328 patients in total,including 768 who underwent operation with polymethylmethacrylateand 560 who received non-operative treatments. For new-level vertebral fractures, our meta-analysis found no significant difference between the 2 methods, including total new fractures (P = 0.55) and adjacent fractures (P = 0.5).For pre-existing vertebral fractures, there was no significant difference between the 2 groups (operative and non-operative groups) (P = 0.24). Additionally,there was no significant difference in bone mineral density, both in the lumbar (P = 0 .13) and femoral neck regions (P = 0.37), between the 2 interventions. Limitation: All studies we screened were published online except for unpublished articles. Moreover, only a few data sources could be extracted from the published studies. There were only 5 randomized clinical trials and 7 prospective studies that met our inclusion criteria. Conclusion: Vertebral augmentation techniques, such as vertebroplasty and kyphoplasty, have been widely used to treat osteoporotic vertebral fractures in order to alleviate back pain and correct the deformity, and it has been frequently reported that many new vertebral fractures occurred after this operation. Our analysis did not reveal evidence of an increased risk of fracture of vertebral bodies, especially those adjacent to the treated vertebrae, following augmentation with either method compared with conservative treatment. Key words: Vertebroplasty, kyphoplasty, new osteoporotic compression vertebral fracture, meta-analysis

2020 ◽  
Author(s):  
Li Fan Jie ◽  
Li Yang ◽  
Wang Yan Jie ◽  
Du YiBin

Abstract Purpose: To evaluate the clinical efficacy and complications of percutaneous curved vertebroplasty in treatment of osteoporotic vertebral compression fractures.Methods: Patients with single vertebral osteoporotic vertebral compression fractures were selected. The patients were divided into Percutaneous curved vertebroplasty group and Percutaneous vertebroplasty group.Distribution and leakage of bone cement and recovery of the height of the anterior edge of the injured vertebra were observed. VAS and ODI were assessed preoperatively 1 day and 1 year postoperatively. Postoperative follow-up was conducted for 1 year to observe the occurrence of adjacent vertebral fractures. The trial was approved by the Ethics Committee of the Third Affiliated Hospital of Anhui Medical University. Results: Compared with the percutaneous vertebroplasty group, distribution of bone cement was more uniform and satisfactory, the leakage rate of bone cement was lower in the percutaneous curved vertebroplasty group. Both the visual analogue scale score and Oswestry disability index of the two groups at 1 day and I year after surgery were significantly improved compared with those before surgery (P < 0.05). There was no significant difference in VAS and ODI. The height of the anterior edge of the injured vertebral body of the two groups improved significantly(P < 0.05), and there was no significant difference between the two groups . There was no significant difference in the incidence of adjacent vertebral fractures between the two groups..Conclusion: The results show that PCVP has beneficial to the uniform distribution of bone cement in the fracture vertebrae and reduce the leakage of bone cement.


2019 ◽  
Vol 48 (4) ◽  
pp. 030006051989476
Author(s):  
Zhangzhe Zhou ◽  
Zhiyong Sun ◽  
Yimeng Wang ◽  
Xiaoyu Zhu ◽  
Zhonglai Qian

Objective To compare the safety and efficacy of kyphoplasty in the treatment of occult and non-occult osteoporotic vertebral compression fractures (OOVF). Material and Methods From 2015 to 2017, 82 OOVF and 105 non-occult osteoporotic vertebral compression fractures (N-OOVF) were evaluated with the Visual Analog Scale (VAS), Oswestry Disability Index (ODI), and vertebral height preoperatively, immediately postoperatively, and one year postoperatively. Operative time, fluoroscopy time, and cement injection volume were recorded. Results Compared with the preoperative VAS and ODI scores, the scores of both groups were significantly improved after surgery. Preoperative ODI and VAS scores of the OOVF were lower than those of the N-OOVF. The operative time, fluoroscopy time, and bone cement injection volume of the OOVF were significantly lower than those of the N-OOVF. Vertebral height of the N-OOVF improved significantly after surgery. There were differences in cement leakage and adjacent vertebral fractures between the two groups. Conclusion Compared with N-OOVF, OOVF are safer with kyphoplasty, and it is necessary to diagnose OOVF in a timely manner.


Sign in / Sign up

Export Citation Format

Share Document