scholarly journals A Coagulation Mode on Bipolar Electrosurgery Unit Using 350 KHz Frequency and Power Selection

Author(s):  
Prastawa Asalim Tetra Putra ◽  
Bambang Guruh Irianto ◽  
Tribowo Indrato ◽  
Lamidi Lamidi ◽  
Rizki Andriyanto ◽  
...  

Losing a lot of blood during surgery using a conventional scalpel is something that is highly avoided. The purpose of this study is to replace the conventional scalpel with a tool that utilizes a high frequency whose duty cycle is regulated and then centered at one point. Researchers take advantage of the effect of heat generated by high frequencies which are centered at one point so that it can be used for the process of surgery and coagulation in body tissues so as to minimize the occurrence of a lot of blood loss. Researchers use a high frequency of 350 KHz which is set with a duty cycle of 6% on 94% off and is equipped with 3 levels of power selection and uses forceps as a medium to concentrate high frequencies at one point. The module design consists of a 350 KHz frequency generator, a pulse control circuit to adjust the duty cycle, a power control circuit as a power setting, a driver circuit to combine the frequency with the set power so that different outputs are obtained according to the settings, and an inverter circuit to increase the voltage. In this study, after measuring using an oscilloscope in the driver circuit, the average output amplitude at each low, medium, and high setting was 27.25 Vpp, 28 Vpp, and 28.625 Vpp. The results showed that the bipolar electrosurgery unit (coagulation) module as a whole can replace conventional scalpels so that it can minimize the occurrence of a lot of blood loss during surgery. However, the frequency generator and power selection need to be improved.

Author(s):  
Ridho Armi Nabawi ◽  
Dhany Alvianto Wibaksono ◽  
Tri Bowo Indrato ◽  
Triana Rahmawati

Electrosurgery Unit is a medical device that utilizes high frequency and voltage used to cut and dry tissue during the surgical process. The purpose of making this tool is to damage certain body tissues by heating the tissue. Heat is obtained by concentrating high frequency electricity on certain body tissues using active and passive electrodes as a medium. The Electrosurgery Unit involves the use of the CMOS 4069 IC as a frequency generator. The output frequency is set at 300 KHz then forwarded to the pulse regulating circuit and controlled with ic atmega328 then forwarded to the inverter circuit which functions to increase the voltage and output in the form of power. The module is calibrated using ESU Analyzer. This module is equipped with LOW, MEDIUM, HIGH. After the measurements are made, the more load is given higher to the tool, the higher the power released by the tool in each power selection. Then the load relationship and the power released are directly proportional. This ESU was made so that during the surgical process the body's tissue does not experience a lot of blood loss. Besides being able to use it for surgery, it can also be used to close the tissue after surgery.


1999 ◽  
Vol 202 (23) ◽  
pp. 3359-3367 ◽  
Author(s):  
G. Jones

I investigated the scaling of echolocation call parameters (frequency, duration and repetition rate) in bats in a functional context. Low-duty-cycle bats operate with search phase cycles of usually less than 20 %. They process echoes in the time domain and are therefore intolerant of pulse-echo overlap. High-duty-cycle (>30 %) species use Doppler shift compensation, and they separate pulse and echo in the frequency domain. Call frequency scales negatively with body mass in at least five bat families. Pulse duration scales positively with mass in low-duty-cycle quasi-constant-frequency (QCF) species because the large aerial-hawking species that emit these signals fly fast in open habitats. They therefore detect distant targets and experience pulse-echo overlap later than do smaller bats. Pulse duration also scales positively with mass in the Hipposideridae, which show at least partial Doppler shift compensation. Pulse repetition rate corresponds closely with wingbeat frequency in QCF bat species that fly relatively slowly. Larger, fast-flying species often skip pulses when detecting distant targets. There is probably a trade-off between call intensity and repetition rate because ‘whispering’ bats (and hipposiderids) produce several calls per predicted wingbeat and because batches of calls are emitted per wingbeat during terminal buzzes. Severe atmospheric attenuation at high frequencies limits the range of high-frequency calls. Low-duty-cycle bats that call at high frequencies must therefore use short pulses to avoid pulse-echo overlap. Rhinolophids escape this constraint by Doppler shift compensation and, importantly, can exploit advantages associated with the emission of both high-frequency and long-duration calls. Low frequencies are unsuited for the detection of small prey, and low repetition rates may limit prey detection rates. Echolocation parameters may therefore constrain maximum body size in aerial-hawking bats.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Gotthold Fläschner ◽  
Cosmin I. Roman ◽  
Nico Strohmeyer ◽  
David Martinez-Martin ◽  
Daniel J. Müller

AbstractUnderstanding the viscoelastic properties of living cells and their relation to cell state and morphology remains challenging. Low-frequency mechanical perturbations have contributed considerably to the understanding, yet higher frequencies promise to elucidate the link between cellular and molecular properties, such as polymer relaxation and monomer reaction kinetics. Here, we introduce an assay, that uses an actuated microcantilever to confine a single, rounded cell on a second microcantilever, which measures the cell mechanical response across a continuous frequency range ≈ 1–40 kHz. Cell mass measurements and optical microscopy are co-implemented. The fast, high-frequency measurements are applied to rheologically monitor cellular stiffening. We find that the rheology of rounded HeLa cells obeys a cytoskeleton-dependent power-law, similar to spread cells. Cell size and viscoelasticity are uncorrelated, which contrasts an assumption based on the Laplace law. Together with the presented theory of mechanical de-embedding, our assay is generally applicable to other rheological experiments.


2013 ◽  
Vol 127 (10) ◽  
pp. 952-956 ◽  
Author(s):  
A Goyal ◽  
P P Singh ◽  
A Vashishth

AbstractObjectives:This study aimed to: understand the effect that high intensity noise associated with drilling (during otological surgery) has on hearing in the contralateral ear; determine the nature of hearing loss, if any, by establishing whether it is temporary or persistent; and examine the association between hearing loss and various drill parameters.Methods:A prospective clinical study was carried out at a tertiary centre. Thirty patients with unilateral cholesteatoma and normal contralateral hearing were included. Patients were evaluated pre-operatively and for five days following surgery using high frequency pure tone audiometry, and low and high frequency transient evoked and distortion product otoacoustic emission testing.Results:The findings revealed statistically significant changes in distortion product otoacoustic emissions at high frequencies (p = 0.016), and in transient evoked otoacoustic emissions at both low and high frequencies (p = 0.035 and 0.021, respectively). There was a higher statistical association between otoacoustic emission changes and cutting burrs compared with diamond burrs.Conclusion:Drilling during mastoid surgery poses a threat to hearing in the contralateral ear due to noise and vibration conducted transcranially.


2000 ◽  
Vol 39 (10) ◽  
pp. 1645-1656 ◽  
Author(s):  
Gail M. Skofronick-Jackson ◽  
James R. Wang

Abstract Profiles of the microphysical properties of clouds and rain cells are essential in many areas of atmospheric research and operational meteorology. To enhance the understanding of the nonlinear and underconstrained relationships between cloud and hydrometeor microphysical profiles and passive microwave brightness temperatures, estimations of cloud profiles for an anvil region, a convective region, and an updraft region of an oceanic squall were performed. The estimations relied on comparisons between radiative transfer calculations of incrementally estimated microphysical profiles and concurrent dual-altitude wideband brightness temperatures from the 22 February 1993 flight during the Tropical Ocean and Global Atmosphere Coupled Ocean–Atmosphere Response Experiment. The wideband observations (10–220 GHz) are necessary for estimating cloud profiles reaching up to 20 km. The low frequencies enhance the rain and cloud water profiles, and the high frequencies are required to detail the higher-altitude ice microphysics. A microphysical profile was estimated for each of the three regions of the storm. Each of the three estimated profiles produced calculated brightness temperatures within ∼10 K of the observations. A majority of the total iterative adjustments were to the estimated profile’s frozen hydrometeor characteristics and were necessary to match the high-frequency calculations with the observations. This requirement indicates a need to validate cloud-resolving models using high frequencies. Some difficulties matching the 37-GHz observation channels on the DC-8 and ER-2 aircraft with the calculations simulated at the two aircraft heights (∼11 km and 20 km, respectively) were noted, and potential causes were presented.


Author(s):  
Minghui Zheng ◽  
Masayoshi Tomizuka

Vibration with multiple large peaks at high frequencies may cause significant performance degradation and have become a major concern in modern high precision control systems. To deal with such high-frequency peaks, it is proposed to design a frequency-shaped sliding mode controller based on H∞ synthesis. It obtains an ‘optimal’ filter to shape the sliding surface, and thus provides frequency-dependent control allocation. The proposed frequency-shaping method assures the stability in the presence of multiple-peak vibration sources, and minimizes the weighted H∞ norm of the sliding surface dynamics. The evaluation is performed on a simulated hard disk drive with actual vibration sources from experiments, and the effectiveness of large vibration peak suppression is demonstrated.


2019 ◽  
Author(s):  
Yun Zhu ◽  
Dainan Li ◽  
Hai Huang

ABSTRACTRetrieval of synaptic vesicles via endocytosis is essential for maintaining sustained synaptic transmission, especially for neurons that fire action potentials at high frequencies. However, how activity regulates synaptic vesicles recycling is largely unknown. Here we report that Na+ substantially accumulated in the mouse calyx of Held terminals during repetitive high-frequency spiking. Elevated presynaptic Na+ accelerated both slow and rapid forms of endocytosis and facilitated endocytosis overshoot but did not affect the readily releasable pool size, Ca2+ influx, or exocytosis. To examine whether this facilitation of endocytosis is related to the Na+-dependent vesicular content change, we dialyzed increasing concentrations of glutamate into the presynaptic cytosol or blocked the vesicular glutamate uptake with bafilomycin and found the rate of endocytosis was not affected by regulating the glutamate content in the presynaptic terminal. Endocytosis is critically dependent on intracellular Ca2+, and the activity of Na+/Ca2+ exchanger (NCX) may be altered when the Na+ gradient is changed. However, neither NCX blocker nor change of extracellular Na+ concentration affected the endocytosis rate. Moreover, two-photon Ca2+ imaging showed that presynaptic Na+ did not affect the action potential-evoked intracellular Ca2+ transient and decay. Therefore, we revealed a novel mechanism of cytosolic Na+ in accelerating vesicle endocytosis. During high-frequency synaptic transmission, when large amounts of synaptic vesicles are fused, Na+ accumulated in terminals, facilitated vesicle recycling and sustained reliable synaptic transmission.


Author(s):  
Metharak Jokpudsa ◽  
Supawat Kotchapradit ◽  
Chanchai Thongsopa ◽  
Thanaset Thosdeekoraphat

High-frequency magnetic field has been developed pervasively. The induction of heat from the magnetic field can help to treat tumor tissue to a certain extent. Normally, treatment by the low-frequency magnetic field needed to be combined with magnetic substances. To assist in the induction of magnetic fields and reduce flux leakage. However, there are studies that have found that high frequencies can cause heat to tumor tissue. In this paper present, a new magnetic application will focus on the analysis of the high-frequency magnetic nickel core with multi-coil. In order to focus the heat energy using a high-frequency magnetic field into the tumor tissue. The magnetic coil was excited by 915 MHz signal and the combination of tissues used are muscle, bone, and tumor. The magnetic power on the heating predicted by the analytical model, the power loss density (2.98e-6 w/m3) was analyzed using the CST microwave studio.


Sign in / Sign up

Export Citation Format

Share Document