scholarly journals Evaluating compressive behavior of general fibrous assemblies

2018 ◽  
Vol 69 (04) ◽  
pp. 287-292
Author(s):  
HUI JING ◽  
WEIDONG YU

General fibrous assemblies are made of loose fibers and air filling in the pores formed by these fibers. An important characteristic of these assemblies is their mechanical behavior under compression and release. In this paper, a unified and systematic experimental investigation was used to quantify and characterize the compressional and recovery behavior of several randomly oriented fibrous assemblies via mechanical and conductive in situ integrated measurement system. An attempt was made to characterize the curves of force, modulus, work and energy loss during compressional and recovery cycles. Considerable hysteresis occurred between the compression and release operations which is an evidence for the existence of fiber slippage and frictional effects. Work, energy loss and recovery rate of work turned out to have a nonlinear exponential relationship with cycles.

Author(s):  
T. Dewolf ◽  
D. Cooper ◽  
N. Bernier ◽  
V. Delaye ◽  
A. Grenier ◽  
...  

Abstract Forming and breaking a nanometer-sized conductive area are commonly accepted as the physical phenomenon involved in the switching mechanism of oxide resistive random access memories (OxRRAM). This study investigates a state-of-the-art OxRRAM device by in-situ transmission electron microscopy (TEM). Combining high spatial resolution obtained with a very small probe scanned over the area of interest of the sample and chemical analyses with electron energy loss spectroscopy, the local chemical state of the device can be compared before and after applying an electrical bias. This in-situ approach allows simultaneous TEM observation and memory cell operation. After the in-situ forming, a filamentary migration of titanium within the dielectric hafnium dioxide layer has been evidenced. This migration may be at the origin of the conductive path responsible for the low and high resistive states of the memory.


2019 ◽  
Vol 12 (11) ◽  
pp. 6113-6124 ◽  
Author(s):  
Fan Zhou ◽  
Shengda Pan ◽  
Wei Chen ◽  
Xunpeng Ni ◽  
Bowen An

Abstract. Air pollution from ship exhaust gas can be reduced by the establishment of emission control areas (ECAs). Efficient supervision of ship emissions is currently a major concern of maritime authorities. In this study, a measurement system for exhaust gas from ships based on an unmanned aerial vehicle (UAV) was designed and developed. Sensors were mounted on the UAV to measure the concentrations of SO2 and CO2 in order to calculate the fuel sulfur content (FSC) of ships. The Waigaoqiao port in the Yangtze River Delta, an ECA in China, was selected for monitoring compliance with FSC regulations. Unlike in situ or airborne measurements, the proposed measurement system could be used to determine the smoke plume at about 5 m from the funnel mouth of ships, thus providing a means for estimating the FSC of ships. In order to verify the accuracy of these measurements, fuel samples were collected at the same time and sent to the laboratory for chemical examination, and these two types of measurements were compared. After 23 comparative experiments, the results showed that, in general, the deviation of the estimated value for FSC was less than 0.03 % (m/m) at an FSC level ranging from 0.035 % (m/m) to 0.24 % (m/m). Hence, UAV measurements can be used for monitoring of ECAs for compliance with FSC regulations.


1992 ◽  
Vol 259 ◽  
Author(s):  
Selmer S. Wong ◽  
Shouleh Nikzad ◽  
Channing C. Ahn ◽  
Aimee L. Smith ◽  
Harry A. Atwater

ABSTRACTWe have employed reflection electron energy loss spectrometry (REELS), a surface chemical analysis technique, in order to analyze contaminant coverages at the submonolayer level during low-temperature in situ cleaning of hydrogen-terminated Si(100). The chemical composition of the surface was analyzed by measurements of the C K, O K and Si L2,3 core loss intensities at various stages of the cleaning. These results were quantified using SiC(100) and SiO2 as reference standards for C and O coverage. Room temperature REELS core loss intensity analysis after sample insertion reveals carbon at fractional monolayer coverage. We have established the REELS detection limit for carbon coverage to be 5±2% of a monolayer. A study of temperature-dependent hydrocarbon desorption from hydrogen-terminated Si(100) reveals the absence of carbon on the surface at temperatures greater than 200°C. This indicates the feasibility of epitaxial growth following an in situ low-temperature cleaning and also indicates the power of REELS as an in situ technique for assessment of surface cleanliness.


2010 ◽  
Vol 21 (10) ◽  
pp. 663-670 ◽  
Author(s):  
Jeffrey J. DiGiovanni ◽  
Ryan M. Pratt

Background: Accurate prescriptive gain results in a more accurate fit, lower return rate in hearing aids, and increased patient satisfaction. In situ threshold measurements can be used to determine required gain. The Widex Corporation uses an in situ threshold measurement strategy, called the Sensogram. Real-ear measurements determine if prescriptive gain targets have been achieved. Starkey Laboratories introduced an integrated real-ear measurement system in their hearing aids. Purpose: To determine whether the responses obtained using the Widex Sensogram were equivalent to those obtained using current clinical threshold measurement methods. To determine the accuracy of the Starkey IREMS™ (Integrated Real Ear Measurement System) in measuring RECD (real-ear to coupler difference) values compared to a dedicated real-ear measurement system. Research Design: A verification design was employed by comparing participant data measured from standard, benchmark equipment and procedures against new techniques offered by hearing-aid manufacturers. Study Sample: A total of 20 participants participated in this study. Ten participants with sensorineural hearing loss were recruited from the Ohio University Hearing, Speech, and Language Clinic participated in the first experiment. Ten participants with normal hearing were recruited from the student population at Ohio University participated in both experiments. The normal-hearing group had thresholds of 15 dB HL or better at the octave frequencies of 250–8000 Hz. The hearing-impaired group had thresholds of varying degrees and configurations with thresholds equal to or poorer than 25 dB HL three-frequency pure-tone average. Data Collection and Analysis: The order of measurement method for both experiments was counterbalanced. In Experiment 1, thresholds obtained via the Widex Sensogram were compared to thresholds obtained for each participant using a clinical audiometer and ER-3A insert ear phones. In Experiment 2, RECD values obtained via the Starkey IREMS were compared to RECD values obtained via the Audioscan Verifit™. A repeated-measures analysis of variance (ANOVA) was used for statistical analysis, and a Fisher's LSD (least significant difference) was used as a post hoc analysis tool. Results: A significant difference between Sensogram thresholds and conventional audiometric thresholds was found with the Sensogram method resulting in better threshold values at 0.5, 1.0, and 2.0 kHz for both groups. In Experiment 2, a significant difference between RECD values obtained by the Starkey IREMS and the Audioscan Verifit system was found with significant differences in RECD values found at 0.25, 0.5, 0.75, 1.5, 2.0, and 6.0 kHz. Conclusions: The Sensogram data differ significantly from traditional audiometry at several frequencies important for speech intelligibility. Real-ear measures are still required for verification of prescribed gain, however, calling into question any claims of shortened fitting time. The Starkey IREMS does perform real-ear measurements that vary significantly from benchmark equipment. These technologies represent a positive direction in prescribing accurate gain during hearing-aid fittings, but a stand-alone system is still the preferred method for real-ear measurements in hearing-aid fittings.


Sign in / Sign up

Export Citation Format

Share Document