Radiation protection instrumentation. Passive integrating dosimetry systems for individual, workplace and environmental monitoring of photon and beta radiation

2005 ◽  
Vol 44 (03) ◽  
pp. 94-98 ◽  
Author(s):  
G. Wunderlich ◽  
K. Behge ◽  
Th. Schönmuth ◽  
J. Kotzerke ◽  
M. Andreeff

SummaryAim: The number of therapies with radiopharmaceuticals labelled with 188Re is increasing requiring the documentation of the beta radiation exposure Hp(0.07) of the staff at all working and production sites and during the application and follow-up of the patient according to the new German Radiation Protection Law (StrlSchV). However, data for β-radiation exposure are rare. Therefore, we determined the personal dose Hp(0.07) of the skin of the hands handling 188Re radiopharmaceuticals to identify steps of high radiation exposure and to optimize working conditions. Method: Thermoluminescence dosimeters (TLD 100) were fixed to the fingertips of the radiochemist, the physician and the nurse and compared to official ring dosimeters. In addition, to monitor radiation exposure continuously readable electronic beta- and gamma dosimeters EPD (Siemens) were used. At eight days in which therapies were performed these readings were evaluated. Results: Considering one therapy with a 188Re-labelled radiopharmaceutical the middle finger of the radiochemist (production) and the physician (application) showed a radiation burden of 894 and 664 μSv/GBq, respectively. The cumulative dose of the fingertips after eight days of therapy was 249 and 110 mSv for the radiochemist and physician, respectively. A cumulative finger dose after eight days of therapy of 17 and 38 μSv/GBq was found for physician and nurse leading to a Hp(0.07) of 3 and 6 mSv, respectively. Preparing the radiopharmaceutical labelled with 20GBq of 188Re the reading of the personal electronic dosimeter of the radiochemist showed a γ-dose rate H . p(10) of 55 μSv/h and a β-dose rate H . p(0.07) of 663 μSv/h which are obviously not representative for the true radiation dose to the skin of the fingertips. Conclusion: During therapy with 188Re-labelled radiopharmaceuticals the true radiation dose to the skin of the finger tips exceeds by far the readings of the official ring dosimeters as well as the continuously readable beta- and gamma dosimeters. This means a risk in exceeding the radiation limit of 500 mSv/a given in the German Radiation Protection Law (§55 StrSchV) primarily in the working field of the radiochemist and the administering physician.


2020 ◽  
Author(s):  
S. Economides ◽  
C.J. Hourdakis ◽  
C. Pafilis ◽  
G. Simantirakis ◽  
P. Tritakis ◽  
...  

This paper concerns an analysis regarding the performance of X-ray equipment as well as the radiological safety in veterinary facilities. Data were collected from 380 X-ray veterinary facilities countrywide during the on-site regulatory inspections carried out by the Greek Atomic Energy Commission. The analysis of the results shows that the majority of the veterinary radiographic systems perform within the acceptable limits; moreover, the design and shielding of X-ray rooms as well as the applied procedures ensure a high level of radiological safety for the practitioners, operators and the members of the public. An issue that requires specific attention in the optimization process for the proper implementation of veterinary radiology practices in terms of radiological safety is the continuous training of the personnel. The above findings and the regulatory experience gained were valuable decision-making elements regarding the type of the regulatory control of veterinary radiology practices in the new radiation protection framework.


Sign in / Sign up

Export Citation Format

Share Document