Surgical instruments. Metallic materials

1991 ◽  
Author(s):  
J. Temple Black

Since its introduction by Fernandez-Moran, the diamond knife has gained wide spread usage as a common material for cutting of thin sections of biological and metallic materials into thin films for examination in the transmission electron microscope. With the development of high voltage E.M. and scanning transmission E.M., microtomy applications will become increasingly important in the preparation of specimens. For those who can afford it, the diamond knife will thus continue to be an important tool to accomplish this effort until a cheaper but equally strong and sharp tool is found to replace the diamond, glass not withstanding.In Figs. 1 thru 3, a first attempt was made to examine the edge of a used (β=45°) diamond knife by means of the scanning electron microscope. Because diamond is conductive, first examination was tried without any coating of the diamond. However, the contamination at the edge caused severe charging during imaging. Next, a thin layer of carbon was deposited but charging was still extensive at high magnification - high voltage settings. Finally, the knife was given a light coating of gold-palladium which eliminated the charging and allowed high magnification micrographs to be made with reasonable resolution.


Author(s):  
J. R. Fekete ◽  
R. Gibala

The deformation behavior of metallic materials is modified by the presence of grain boundaries. When polycrystalline materials are deformed, additional stresses over and above those externally imposed on the material are induced. These stresses result from the constraint of the grain boundaries on the deformation of incompatible grains. This incompatibility can be elastic or plastic in nature. One of the mechanisms by which these stresses can be relieved is the activation of secondary slip systems. Secondary slip systems have been shown to relieve elastic and plastic compatibility stresses. The deformation of tungsten bicrystals is interesting, due to the elastic isotropy of the material, which implies that the entire compatibility stress field will exist due to plastic incompatibility. The work described here shows TEM observations of the activation of secondary slip in tungsten bicrystals with a [110] twist boundary oriented with the plane normal parallel to the stress axis.


2000 ◽  
Vol 10 (PR9) ◽  
pp. Pr9-641-Pr9-646
Author(s):  
P. Chevrier ◽  
J. R. Klepaczko
Keyword(s):  

1400 ◽  
Author(s):  
Abū al-Qāsim Khalaf ibn ʻAbbās a
Keyword(s):  

Author(s):  
Kurniawansyah I. S. ◽  
Mita S. R. ◽  
Najla E. ◽  
Nindayani E.

Healthcare associated infection is one of the common infection that happens in Indonesia. One form control to prevent healthcare associated infection is the sterilization process of the materials and medical instruments that used for taking care of patients. At the private hospital whereas a place of research, there’s never been done the study of sterility test for reusable instrument with pouches, based on previous studies showed that 8 sets from 40 sets of reusable instrument with linen were not sterile moreover there were positively influence from the amount of time to the sterility of reusable instrument. The purpose of these studies was to determining the relationship between a long storage time and the sterility of reusable instruments with pouches. The method that used in this study was the sterility testing of reusable instrument with pouches which were stored in a central operations room storage with a long storage time of 1 and 2 months. From 30 reusable instruments with pouches which were stored for nine months there were 5 instruments were not sterile. The results of statistic analysis showed that the amount of storage time not significantly associated to the sterility of reusable instrument with pouches in the operating room central storage space.


Sign in / Sign up

Export Citation Format

Share Document