Photography. Determination of residual thiosulfate and other related chemicals in processed photographic materials. Methods using iodine-amylose, methylene blue and silver sulfide

1995 ◽  
Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1612
Author(s):  
Andrea Paut ◽  
Ante Prkić ◽  
Ivana Mitar ◽  
Perica Bošković ◽  
Dražan Jozić ◽  
...  

A novel ion-selective electrode with membranes based on iron(III) phosphate and silver sulfide integrated into a completely new electrode body design has been developed for the determination of iron(III) cations. The best response characteristics with linear potential change were found in the iron(III) concentration range from 3.97× 10−5 to 10−2 mol L−1. The detection limit was found to be 2.41× 10−5 mol L−1 with a slope of –20.53 ± 0.63 and regression coefficient of 0.9925, while the quantification limit was 3.97× 10−5 M. The potential change per concentration decade ranged from –13.59 ± 0.54 to –20.53 ± 1.56 for Electrode Body 1 (EB1) and from –17.28 ± 1.04 to –24 ± 1.87 for Electrode Body 2 (EB2), which is presented for the first time in this work. The prepared electrode has a long lifetime and the ability to detect changes in the concentration of iron cations within 20 s. Membrane M1 showed high recoveries in the determination of iron cations in iron(III) standard solutions (98.2–101.2%) as well as in two different pharmaceuticals (98.6–106.5%). This proves that this type of sensor is applicable in the determination of ferric cations in unknown samples, and the fact that all sensor parts are completely manufactured in our laboratory proves the simplicity of the method.


2014 ◽  
Vol 2014 ◽  
pp. 1-10 ◽  
Author(s):  
Gen Liu ◽  
Wei Ma ◽  
Yan Luo ◽  
Deng-ming Sun ◽  
Shuang Shao

Poly(methylene blue) and electrochemically reduced graphene oxide composite film modified electrode (PMB-ERGO/GCE) was successfully fabricated by electropolymerization and was used for simultaneous determination of uric acid (UA) and xanthine (Xa). Based on the excellent electrocatalytic activity of PMB-ERGO/GCE, the electrochemical behaviors of UA and Xa were studied by cyclic voltammetry (CV) and square wave voltammetry (SWV). Two anodic sensitive peaks at 0.630 V (versus Ag/AgCl) for UA and 1.006 V (versus Ag/AgCl) for Xa were given by CV in pH 3.0 phosphate buffer. The calibration curves for UA and Xa were obtained in the range of 8.00 × 10−8~4.00 × 10−4 M and 1.00 × 10−7~4.00 × 10−4 M, respectively, by SWV. The detection limits for UA and Xa were3.00×10-8 M and5.00×10-8 M, respectively. Finally, the proposed method was applied to simultaneously determine UA and Xa in human urine with good selectivity and high sensitivity.


1970 ◽  
Vol 1 (4) ◽  
pp. 102-105 ◽  
Author(s):  
M Alam ◽  
MM Rahman ◽  
MJ Foysal ◽  
MN Hossain

The toxic effects of four disinfectants viz., copper sulfate (CuSO4), potassium permanganate (KMnO4), methylene blue and malachite green on fish and fish pathogenic bacteria Aeromonas sp., Pseudomonas fluorescens, Edwardsiella sp. and Flavobacterium sp. were investigated. Lethal concentration of the disinfectants to fingerlings of Labeo rohita was determined in aquarium by standard method. Lethal concentration of copper sulfate (CuSO4), potassium permanganate (KMnO4), methylene blue and malachite green against fish were found in 0.75ppm, 7ppm, 6ppm and 0.5ppm at 21.4hrs, 18hrs, 9.5hrs and 1.40hrs, respectively. Methylene blue at 4ppm and 5ppm concentration inhibited the growth of Pseudomonas fluorescens and 6ppm concentration suppressed the growth of Aeromonas sp. Copper sulfate (CuSO4) was effective only against Edwardsiella sp at concentration of 10ppm and 8ppm. Malachite green repressed the growth of all four tasted bacteria at a concentration of 1ppm. Potassium permanganate (KMnO4) was failed to exhibit any inhibitory effect on the bacteria even at 30ppm concentration. DOI: http://dx.doi.org/10.3329/ijns.v1i4.9738 IJNS 2011 1(4): 102-105


Sign in / Sign up

Export Citation Format

Share Document