scholarly journals Numerical Investigation of Degasification in an Electrocoagulation Reactor

Water ◽  
2021 ◽  
Vol 13 (19) ◽  
pp. 2607
Author(s):  
Thomas Höhne ◽  
Vahid Farhikhteh Asl ◽  
Loreen Ople Villacorte ◽  
Mark Herskind ◽  
Maryam Momeni ◽  
...  

In order to enhance retention of particulate and colloidal (organic) matter, chemical coagulation (CC) is often used prior to pressure-driven membrane filtration. This combined hybrid membrane system may be a potential solution for environmental problems dealing with drinking water treatment, water reuse, and rational waste management. In this study, an EC reactor with spiral electrodes was investigated numerically, focusing on modeling with a given design/geometry configuration and boundary conditions. Two-phase flow interactions between water and hydrogen were modeled via computational fluid dynamics (CFD). Different flow rates (Q=1−1000 l/h) through two batches of the watering stage (Case 1–3) and the degassing stage (Case 4–6) were simulated. The results provided information about flow characteristics such as sufficient retention time, water circulation, undesirable gas penetration into the water inlet channel, gas holdup during watering and degassing, and finally the optimal period for the degasification. Retention time decreases with increasing water velocity and thirty seconds seemed to be the optimal time with gas holdup of 0.020%, 0.028%, and 0.027%, respectively, for Case 4, Case 5, and Case 6. Another finding is that the consideration for the most abundant gas holdup for the typical BC was the smallest ratio of water to gas flow.

2002 ◽  
Vol 56 (5) ◽  
pp. 198-203 ◽  
Author(s):  
Olivera Naseva ◽  
Ivica Stamenkovic ◽  
Ivana Bankovic-Ilic ◽  
Miodrag Lazic ◽  
Vlada Veljkovic ◽  
...  

The gas holdup was studied in non-newtonian liquids in a gas-liquid and gas-liquid-solid reciprocating plate bioreactor. Aqueous solutions of carboxy methyl cellulose (CMC; Lucel, Lucane, Yugoslavia) of different degrees of polymerization (PP 200 and PP 1000) and concentration (0,5 and 1%), polypropylene spheres (diameter 8.3 mm; fraction of spheres: 3.8 and 6.6% by volume) and air were used as the liquid, solid and gas phase. The gas holdup was found to be dependent on the vibration rate, the superficial gas velocity, volume fraction of solid particles and Theological properties of the liquid ohase. Both in the gas-liquid and gas-liquid-solid systems studied, the gas holdup increased with increasing vibration rate and gas flow rate. The gas holdup was higher in three-phase systems than in two-phase ones under otter operating conditions being the same. Generally the gas holdup increased with increasing the volume fraction of solid particles, due to the dispersion action of the solid particles, and decreased with increasing non-Newtonian behaviour (decreasing flow index) i.e. with increasing degree of polymerization and solution concentration of CMC applied, as a result of gas bubble coalescence.


2005 ◽  
Vol 59 (9-10) ◽  
pp. 263-266
Author(s):  
Ljubisa Vasic ◽  
Ivana Bankovic-Ilic ◽  
Miodrag Lazic ◽  
Vlada Veljkovic ◽  
Dejan Skala

The effects of operation conditions (the vibration intensity and gas flow rate) on the gas holdup in a 16.6 cm i.d. two-phase reciprocating plate column (RPC) were studied. Distilled water and aqueous solutions of carboxymethyl-cellulose of different concentration were used as the liquid phase and air as the gas phase in this investigation. The gas holdup was measured after the gas flow and the reciprocating action had been stopped. An empirical correlation which correlates the gas holdup with the specific power consumption and the superficial gas velocity showed that the aeration intensity had a greater influence on the gas holdup than the intensity of agitation. Because the gas holdup was approximately the same in RPC's of different diameters, an equation relating the gas holdup with the specific power consumption and the superficial gas velocity was derived. The correlation could be used in the scaling up of reciprocating plate columns.


2014 ◽  
Vol 70 (2) ◽  
pp. 272-278 ◽  
Author(s):  
R. Pagotto ◽  
R. Rossetto ◽  
R. L. P. Gasperi ◽  
J. P. Andrade ◽  
J. Trovati ◽  
...  

The macro region of Campinas (Brazil) is rapidly evolving with new housing developments and industries, creating the challenge of finding new ways to treat wastewater to a quality that can be reused in order to overcome water scarcity problems. To address this challenge, SANASA (a publicly owned water and wastewater concessionaire from Campinas) has recently constructed the ‘EPAR (Water Reuse Production Plant) Capivari II’ using the GE ZeeWeed 500D® ultrafiltration membrane system. This is the first large-scale membrane bioreactor (MBR) system in Latin America with biological tertiary treatment capability (nitrogen and phosphorus removal), being able to treat an average flow of 182 L/s in its first phase of construction. The filtration system is composed of three membrane trains with more than 36,000 m2 of total membrane filtration area. The membrane bioreactor (MBR) plant was commissioned in April 2012 and the permeate quality has exceeded expectations. Chemical oxygen demand (COD) removal rates are around and above 97% on a consistent basis, with biochemical oxygen demand (BOD5) and NH3 (ammonia) concentrations at very low levels, and turbidity lower than 0.3 nephelometric turbidity unit (NTU). Treated effluent is sent to a water reuse accumulation tank (from where will be distributed as reuse water), and the excess is discharged into the Capivari River.


1998 ◽  
Vol 38 (4-5) ◽  
pp. 513-520 ◽  
Author(s):  
O. Mizuno ◽  
H. Takagi ◽  
T. Noike

The biological sulfate removal in the acidogenic bioreactor with an ultrafiltration membrane system was investigated at 35°C. Sucrose was used as the sole organic substrate. The sulfate concentration in the substrate ranged from 0 to 600mgS·1−1. The chemostat reactor was operated to compare with the membrane bioreactor. The fouling phenomenon caused by FeS precipitate was observed at higher concentration of sulfate. However, it was possible to continuously operate the membrane bioreactor by cleaning the membrane. The efficiency of sulfate removal by sulfate reduction reached about 100% in the membrane bioreactor, and 55 to 87% of sulfide was removed from the permeate by the membrane filtration. The composition of the metabolite was remarkably changed by the change in sulfate concentration. When the sulfate concentration increased, acetate and 2-proponol significantly increased while n-butyrate and 3-pentanol decreased. The sulfate-reducing bacteria play the role as acetogenic bacteria consuming volatile fatty acids and alcohols as electron donors under sulfate-rich conditions. The results show that the acidogenesis and sulfate reduction simultaneously proceed in the membrane bioreactor.


1998 ◽  
Vol 38 (4-5) ◽  
pp. 443-452
Author(s):  
Katsuki Kimura ◽  
Yoshimasa Watanabe ◽  
Naoki Ohkuma

Membrane filtration and oxidation of ammonia were simultaneously performed by using a rotating membrane disk module. Nitrification performance, composition of the accumulated cakes on the membrane and the filtration resistances were investigated under five different operating conditions. The filtration resistance due to the accumulated cake on the membrane was found to be dominant in this treatment method, compared to the resistance due to the micropore plugging or irreversible adherence. The cake consisted mainly of iron, humic substances and bacteria. The possibility that extracellular polymeric substances were related to the cake resistance was also shown. The composition of the cake depended on the length and the condition of operation. Accumulation of ammonia oxidizers caused by oxidation of low concentrations of ammonia (less than 1 mg/l) did not increase transmembrane pressure significantly. Therefore, the application of this treatment method for drinking water treatment is feasible. Filtration resistance due to the micropore plugging or irreversible adherence to the membrane was caused by organic substances.


2003 ◽  
Vol 3 ◽  
pp. 266-270
Author(s):  
B.H. Khudjuyerov ◽  
I.A. Chuliev

The problem of the stability of a two-phase flow is considered. The solution of the stability equations is performed by the spectral method using polynomials of Chebyshev. A decrease in the stability region gas flow with the addition of particles of the solid phase. The analysis influence on the stability characteristic of Stokes and Archimedes forces.


1986 ◽  
Vol 51 (5) ◽  
pp. 1001-1015 ◽  
Author(s):  
Ivan Fořt ◽  
Vladimír Rogalewicz ◽  
Miroslav Richter

The study describes simulation of the motion of bubbles in gas, dispersed by a mechanical impeller in a turbulent low-viscosity liquid flow. The model employs the Monte Carlo method and it is based both on the knowledge of the mean velocity field of mixed liquid (mean motion) and of the spatial distribution of turbulence intensity ( fluctuating motion) in the investigated system - a cylindrical tank with radial baffles at the wall and with a standard (Rushton) turbine impeller in the vessel axis. Motion of the liquid is then superimposed with that of the bubbles in a still environment (ascending motion). The computation of the simulation includes determination of the spatial distribution of the gas holds-up (volumetric concentrations) in the agitated charge as well as of the total gas hold-up system depending on the impeller size and its frequency of revolutions, on the volumetric gas flow rate and the physical properties of gas and liquid. As model parameters, both liquid velocity field and normal gas bubbles distribution characteristics are considered, assuming that the bubbles in the system do not coalesce.


Membranes ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 369
Author(s):  
Shengji Xia ◽  
Xinran Zhang ◽  
Yuanchen Zhao ◽  
Fibor J. Tan ◽  
Pan Li ◽  
...  

The membrane separation process is being widely used in water treatment. It is very important to control membrane fouling in the process of water treatment. This study was conducted to evaluate the efficiency of a pre-oxidation-coagulation flat ceramic membrane filtration process using different oxidant types and dosages in water treatment and membrane fouling control. The results showed that under suitable concentration conditions, the effect on membrane fouling control of a NaClO pre-oxidation combined with a coagulation/ceramic membrane system was better than that of an O3 system. The oxidation process changed the structure of pollutants, reduced the pollution load and enhanced the coagulation process in a pre-oxidation-coagulation system as well. The influence of the oxidant on the filtration system was related to its oxidizability and other characteristics. NaClO and O3 performed more efficiently than KMnO4. NaClO was more conducive to the removal of DOC, and O3 was more conducive to the removal of UV254.


2013 ◽  
Author(s):  
Sung Chan Cho ◽  
Yun Wang

In this paper, two-phase flow dynamics in a micro channel with various wall conditions are both experimentally and theoretically investigated. Annulus, wavy and slug flow patterns are observed and location of liquid phase on different wall condition is visualized. The impact of flow structure on two-phase pressure drop is explained. Two-phase pressure drop is compared to a two-fluid model with relative permeability correlation. Optimization of correlation is conducted for each experimental case and theoretical solution for the flows in a circular channel is developed for annulus flow pattern showing a good match with experimental data in homogeneous channel case.


Sign in / Sign up

Export Citation Format

Share Document